XLPE PVC PE Abc Aluminium Cable Five Core For Aerial Power Transmission
XLPE PVC PE Abc Aluminium Cable Five Core For Aerial Power Transmission image
Brand Name :
Huanghe
Model Number :
ABC Cable
Certification :
IOS, OHSAS, CCC, IEC
Place of Origin :
China
MOQ :
1000 meters
Payment Terms :
L/C, T/T, Western Union
Supply Ability :
50000 meters per week
Delivery Time :
5-8 days
Packaging Details :
Wooden Drum, Steel Wooden Drum, Coil
Conductor :
Copper, Aluminum, Aluminum Alloy
Insulation :
XLPE, PVC, PE
Colour :
Black or as your request
Standard :
GB/T12527, BS, IEC, ASTM, DIN
Rated Voltage :
1kv, 10kv, 35kv
Packing :
Wooden Drum, Steel Wooden Drum, Coil
Sample :
Free, Offered
XLPE PVC PE Abc Aluminium Cable Five Core For Aerial Power Transmission
Standard of ABC Aerial Bundled Cable
IEC228, IEC209, IEC60502, ASTM ANSI/ICEA S-76-474, NFC 33-209,HRN HD 626 S1 / DIN VDE 0276 part 626 / BS7870/ GB/T12527-2008
Type of ABC Aerial Bundled Cable
No. | Product Type | Application |
1 | PVC insulated aerial bundle cable | For aerial power transmission |
2 | PE insulated aerial bundle cable | |
3 | XLPE insulated aerial bundle cable | |
4 | Steel reinforced aluminum wire with PVC insulated aerial b undle cable | For aerial power transmission, able to bear moderate pulling force. |
Production Range of ABC Aerial Bundled Cable
Voltage: 1kv, 10kv, 35kv
No. of cores: 1, 2, 3, 4, 5, 3+1, 4+1, 3+2
Nominal cross sectional area: 10~1500mm2
Construction of ABC Aerial Bundled Cable:
Phase conductor: copper, aluminum, aluminum alloy stranded
Neutral conductor: aluminum stranded(AAC), aluminum alloy stranded(AAAC), Aluminum conductor steel reinforced(ACSR)
Insulation: PVC, XLPE, PE
(Remark: This is just the normal construction. HUANGHE CABLE can also design and produce the cables according to your special requirement.)
Application of ABC Aerial Bundled Cable:
Insulated Single Core Aerial Cable
Covered line wire is used primarily for overhead secondary distribution lines.It is not an electrically insulated conductor and is treated as bare conductor when installed.
Duplex Service Drop Cable
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 °C maximum.
Triplex Service Drop Cable
To supply power from the utility’s lines to the consumer’s weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75°Cmaximum for polyethylene insulation or 90°C maximum for cross linked insulation.
Quadruplex Service Drop Cable
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltage of 600 volts or less phase to phase and at conductor temperature no to exceed 75°C for polyethylene insulated conductor or 90°C for cross linked polyethylene insulated conductors.
600V ABC Aerial Bundled Cable Data
Number of Cores x Nominal Cross Section | Overall Diameter | Weight | Maximum Conductor Resistance | Minimum Breaking Load | Current Rating |
No.×mm² | mm | Kg/Km | Ω/Km | kN | A |
1×16 RM | 8,0 | 74 | 1910 | 2,5 | 72 |
1×25 RM | 9,0 | 106 | 1200 | 4,0 | 107 |
1×95 RM | 15,4 | 333 | 0,320 | 13,7 | 240 |
1×185 RM | 21,0 | 611 | 0,164 | 28,7 | 389 |
1×240 RM | 24,0 | 801 | 0,125 | 37,2 | 467 |
2×16 RM | 15,6 | 147 | 1910 | 2,5 | 72 |
2×25 RM | 18,0 | 208 | 1200 | 4,0 | 107 |
2×70 RM | 25,4 | 505 | 0,443 | 10,7 | 205 |
4×16 RM | 18,8 | 286 | 1910 | 2,5 | 72 |
4×70 RM | 31,8 | 1.009 | 0,443 | 10,7 | 205 |
4×95 RM | 37,8 | 1.332 | 0,320 | 13,7 | 240 |
4×70 + 1×25 RM | 360 | 1105 | 0,443/1,200 | 10,7/4,0 | 205/107 |
4×70 + 2×25 RM | 400 | 1217 | 0,443/1,200 | 10,7/4,0 |
205/107 |
We are China XLPE PVC PE Abc Aluminium Cable Five Core For Aerial Power Transmission manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: ABC Power Cable, aerial bunched cable, Aerial Bundled Cable