XLPE Insulated Medium Voltage Power Cables( Unarmoured )Copper Conductor 6-36 kV

 China XLPE Insulated Medium Voltage Power Cables( Unarmoured )Copper Conductor 6-36 kV supplier

XLPE Insulated Medium Voltage Power Cables( Unarmoured )Copper Conductor 6-36 kV image

Get a Quote Email to us

MOQ :
Negotiable

Price :
Negotiable

Payment Terms :
T/T, L/C

Supply Ability :
20,000 KM per Month

Delivery Time :
7/10 working days

Packaging Details :
Steel wooden drum

Brand Name :
Chengtiantai

Model Number :
YJV

Certification :
CE, CB

Place of Origin :
Shenzhen, China ( mainland)

Nominal Voltage :
6~20 kV

Insulation :
XLPE

No. of Conductor :
3 core

Sheath :
PVC Compound

Conductor Material :
Bare Copper Class 2

Manufacturer :
Shenzhen Chengtiantai

3 Core XLPE Insulated Medium Voltage Power Cable 3.6/ 6 kV, 6/ 10 kV, 8.7/ 15 kV, 12/20 kV

XLPE Insulated, Copper conductor, 3 core, screened, PVC sheathed

The 3 cores XLPE Insulated MV power cables are designed for distribution of electrical power with nominal voltage Uo/ U: 3.6/ 6 kV, 6/ 10 kV, 8.7/ 15 kV, 12/20 kV and frequency 50Hz.

This XLPE Insulated cables are widely used in the building and construction, renewable energy, and power transmission industries where the cables can be laid directly into the ground or cable ducts.

Construction of XLPE Insulated MV Cable

CONSTRUCTION OF XLPE INSULATED MV CABLE:

1. CONDUCTOR

– Bare copper class 2 to IEC 60228, round, multiwire stranded and compact

2. CONDUCTOR SCREEN

– Inner semi-conducting coating

3. INSULATION

– Core insulation of cross-linked polyethylene (XLPE)

4. INSULATION SCREEN

– Outer conductive layer extruded and per-manently welded with the core insulation

Semi-conducting type
– Over the outer semi-conducting layer, a semiconducting tape must be used.

5. METAL SCREEN

– copper tapes helically with a minimum thickness of 0,1 mm.

Separator
– Over the screen as well as under outer sheath, a separating layer must be used (e. g. taping).

6. FILLER

– PP filler

7. WRAPPING TAPE

8. SHEATH

– Outer sheath of PVC compound

Core identification:

– Colored tapes under screen.

STANDER

International:IEC60502-2

National:GB/T 12706.1-2008

Special Feature
On Request

Flame Retardant Cat.C
Flame Retardant Non Category
Anti-termite
Anti-Rodent
UV Resistance
Low Smoke Zero Halogen

TECHNICAL DATA OF XLPE Insulated copper cable

Temperature range
– during installation up to -5°C

Operating temperature
– max. +90°C

Short circuit temperature
+250°C (short circuit duration max. 5 s)

Minimum bending radius
– 15 x cable Ø

Breaking strength:

– min. 200%
Tensile strength:

– min. 12,5 N/mm2

Nominal voltage
– U0/U 3.6/6 kV, 6/10 kV, 8.7/15 kV, 12/20 kV

Operating voltage, 50 Hz

– for 3.6/6 kV= max. 7.2 kV
– for 6/10 kV = max. 12 kV

– for 8.7/15 kV = max. 17.5 kV
– for 12/20 kV = max. 24 kV

Test voltage(V/5 min)

– for 3.6/6 kV= 12.5 kV
– for 6/10 kV = 21 kV

– for 8.7/15 kV = 30.5KV
– for 12/20 kV = 42 kV

3,6/ 6 kV XLPE Insulated Power cable, Copper conductor, screened, PVC sheathed

No. of cores

nominal cross section

Operation
voltage
max.

Nominal
voltage
U0/U

Insulation
thickness

Sheath
thickness
Nominal
value

Outer Ø
approx.

weight
approx.

Current ratings in air 30℃

Current ratings buried 20℃

maximum DC resistance at 20℃

No.

mm²

kV

kV

mm

mm

mm

kg / km

A

A

Ω/km

3

35

7.2

3.6 / 6

2.5

2.2

38.5

2073

142

185

0.52

3

50

7.2

3.6 / 6

2.5

2.3

41.5

2614

169

216

0.39

3

70

7.2

3.6 / 6

2.5

2.4

44.3

3317

210

264

0.27

3

95

7.2

3.6 / 6

2.5

2.5

49.3

4183

257

316

0.19

3

120

7.2

3.6 / 6

2.5

2.6

52.5

5014

298

360

0.15

3

150

7.2

3.6 / 6

2.5

2.7

56.1

6000

336

402

0.12

3

185

7.2

3.6 / 6

2.5

2.8

59.8

7154

393

461

0.10

3

240

7.2

3.6 / 6

2.6

3.0

64.9

8925

463

533

0.08

3

300

7.2

3.6 / 6

2.8

3.2

71.3

10937

526

599

0.06

3

400

7.2

3.6 / 6

3.0

3.5

80.3

14214

605

680

0.05

6/ 10 (12) kV XLPE Insulated power cable, Copper conductor, screened, PVC sheathed

No. of cores

nominal cross section

Operation
voltage
max.

Nominal
voltage
U0/U

Insulation
thickness

Sheath
thickness
Nominal
value

Outer Ø
approx.

weight
approx.

Current ratings in air 30℃

Current ratings buried 20℃

maximum DC resistance at 20℃

No.

mm

kV

kV

mm

mm

mm

kg / km

A

A

Ω/km

3

50

12

6/ 10

3.4

2.4

44.4

2636

169

216

0.39

3

70

12

6/ 10

3.4

2.5

48.1

3336

148

183

0.27

3

95

12

6/ 10

3.4

2.7

52

4185

178

218

0.19

3

120

12

6/ 10

3.4

2.8

55.2

5009

246

266

0.15

3

150

12

6/ 10

3.4

2.9

58.7

5979

267

318

0.12

3

185

12

6/ 10

3.4

3.0

62.5

7109

308

361

0.1

3

240

12

6/ 10

3.4

3.1

67.6

8845

335

406

0.08

8.7/ 15 (17.5) kV XLPE Insulated power cable, Copper conductor, screened, PVC sheathed

No.cores x
cross-sec.

Operation
voltage
max.

Nominal
voltage
U0/U

Insulation
thickness

Sheath
thickness
Nominal
value

Outer Ø
approx.

weight
approx.

Current ratings in air 30℃

Current ratings buried 20℃

maximum DC resistance at 20℃

mm²

kV

kV

mm

mm

mm

kg / km

A

A

Ω/ km

3 x 35

17.5

8.7 / 15

4.5

2.5

48

2682

148

183

0.52

3 x 50

17.5

8.7 / 15

4.5

2.6

51

3265

178

218

0.39

3 x 70

17.5

8.7 / 15

4.5

2.7

54.8

4014

246

266

0.27

3 x 95

17.5

8.7 / 15

4.5

2.8

58.5

4898

267

318

0.19

3 x 120

17.5

8.7 / 15

4.5

2.9

61.7

5767

308

361

0.15

3 x 150

17.5

8.7 / 15

4.5

3.0

65.3

6833

335

406

0.12

3 x 185

17.5

8.7 / 15

4.5

3.1

69

8040

394

461

0.1

3 x 240

17.5

8.7 / 15

4.5

3.3

74.1

9945

465

529

0.08

3 x 300

17.5

8.7 / 15

4.5

3.5

79.1

11863

528

593

0.06

3 x 400

17.5

8.7 / 15

4.5

3.7

89.1

15320

622

682

0.05

12/ 20 (12) kV XLPE Insulated MV Power cable, Cu, screened, PVC sheathed

No.cores x
cross-sec.

Operation
voltage
max.

Nominal
voltage
U0/U

Insulation
thickness

Sheath
thickness
Nominal
value

Outer Ø
approx.

weight
approx.

Current ratings in air 30℃

Current ratings buried 20℃

maximum DC resistance at 20℃

mm²

kV

kV

mm

mm

mm

kg / km

A

A

Ω/km

3 x 35

24

12/20

5.5

2.6

52.5

3023

155

185

0.52

3 x 50

24

12/20

5.5

2.7

55.5

3891

180

218

0.39

3 x 70

24

12/20

5.5

2.8

59.3

4396

223

267

0.27

3 x 95

24

12/20

5.5

3.0

63

5264

271

318

0.19

3 x 120

24

12/20

5.5

3.1

66.2

6190

312

363

0.15

3 x 150

24

12/20

5.5

3.2

69.8

7240

363

417

0.12

3 x 185

24

12/20

5.5

3.3

73.7

8499

404

460

0.1

3 x 240

24

12/20

5.5

3.5

78.6

10353

471

531

0.08

3 x 300

24

12/20

5.5

3.6

83.8

12328

536

596

0.06

3 x 400

24

12/20

5.5

3.8

93.6

15921

630

684

0.05

XLPE INSULATED MEDIUM VOLTAGE CABLE TESTING

Routine tests:

Sample tests:

Type tests:

These non-destructive tests are normally carried out on all lengths manufactured.
– Conductor resistivity
– Spark test on oversheath
– Voltage tests on sheath
– D.C. voltage test on oversheath

These potentially destructive tests are normally carried out on every production run.
– Examination of conductor and dimensions
– Hot set test for XLPE insulation
– Insulation and oversheath thickness
– Four hour voltage test

These destructive tests are normally carried out in addition to the above tests on commencement of a particular cable supply to validate its design.
– Electrical type tests including bending and heat cycle
– Non-electrical type tests including mechanical properties after ageing and tests under fire conditions.

PACKING AND SHIPPING

Packing: steel wooden drum, other as required ; standard delivery length is 300 m

Packaging details :

Delivery :

Steel Wooden Drums

Cable Drum In container

shipped in 15 days after payment

Cable Drum Data

CABLE DRUMS

D1=Flange Diameter(mm)

W=Useful Width (mm)

D2=Barrel Diameter(mm)

1000

700

500

1100

700

550

1200

700

600

1400

750

710

1600

900

900

1800

1120

1000

2400

1150

1300

Delivery Port:

Port of Shenzhen

Port of Hongkong

Port of Guangzhou

Our production in numbers

● Cable production started 1983
● 35 years of cable manufacturing experience

● Sales in 2016 about 500 million USD

● 100,000 m2 Production area
● 350 Will-trained employees
● Exported more than 22 countries
● 2 Manufacturing plant
● 1 R&D Center

● 200 Sets Of Testing Equipment

● 100 Testing Items
● 8 workshop
● 40 wire drawing machines
● 10 bunching machines
● 28 Extruder system
● 42 stranding machines
● 10 Braiding machines

Shenzhen chengtiantai cable operates certified management systems compliant with:

Certificat

Information

ISO 9001:2008

Quality management systems

Certificat ISO 9001:2008
– Shenzhen chengtiantai cable industry development Co.Ltd. ;
Certified through Guangdong quality Testing CTC Certification Co.Ltd.;
Valid until 13 January 2019

ISO 14001:2004

Environmental management systems

Certificat ISO 14001:2004

– Shenzhen chengtiantai cable industry development Co.Ltd. ;

Certified through Guangdong quality Testing CTC Certification Co.Ltd.;

Valid until 13 January 2019

OHSAS 18001:2007

Assessment specification for occupational health & safety management systemsenvironmental management systems

Certificat OHSAS 18001:2007
– Shenzhen chengtiantai cable industry development Co.Ltd. ;
Certified through Guangdong quality Testing CTC Certification Co.Ltd.;
Valid until 13 January 2019

Manufacturing Process Of Medium Voltage Power Cable

1. copper rod

2. wire drawing

3. wire stranding

4.Triple Extrusion Insulation

5.Screening Process

6. outer covering Process

7. Sheath Marking

8. Packing

9. Partial discharge Inspection

Some great shot on our manufacturing plant

Located in: Chengtiantai Industrial Park, Guangming New District, Shen zhen P. R. China 518106

RECOMMENDED ORDERING PARAMETERS

CONTACT

For prompt quotation / supplies please make sure your inquiries and your orders are
securing the following data :

1 – International or Special Standard. (Alternatively, the precise usage of the cable.)
2 – Rated voltage.
3 – Copper or Aluminium conductors.
4 – Size of each conductor.
5 – Insulation material : XLPE or others.
6 – Number and identification of conductors.
7 – Other requirements.
8 – Packing.
9 – Required delivery time.
10 – Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.

We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

Tel:+86 755 6114 5028
Fax:+86 755 61137976
E-mail : [email protected]
Head office:chengtiantai Industrial Park, Lisonglang community, Gongming office, Guangming district, Shenzhen P.R. China 518106

Sales Support

haven't found what you were looking for. contact our Sales manager [email protected] provide your contact information so that we can contact you soon to help with your request.

WARRANTY

For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

We are China XLPE Insulated Medium Voltage Power Cables( Unarmoured )Copper Conductor 6-36 kV manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION