Conductor Material :
Copper / Aluminum
Jacket / Outer Sheath :
PVC / PE
Sheath color :
Black or as per requirement
Rated voltage :
0.6/1KV
Insulation thickness :
0.7-1.8mm
Test Voltage :
3.5kv
Size :
1.5 – 800 sqmm
Type :
Low Voltage
Insulation :
XLPE
Application :
control cables used in tool machines, steel production units, electrical substations etc.
Control Cables (Armoured / Unarmoured – PVC / XLPE)
Technical Specifications | |
Core colours | Black / grey with reverse colour numbering + yellow / green |
Sheath colour | Grey, Black and white |
Conductor | Annealed Bare Copper as per IS : 8130 |
PVC Insulation | Type A conforming to IS:5831 |
PVC Sheath | Type ST-1 conforming to IS :5831 HR, FR & FRLS sheathing as per requirement |
Rated voltage | 650/1100V |
Test Voltage | 2000 V.A.C. |
Min. bending radius | 4 time overall diameter of cable |
Tensile strength | 12.50 N per sq.mm of PVC insulation and sheath |
Max. working temperature | 70°C, also available for 85°C as per requirement |
Max short circuit temperature | 160°C |
Minimum Laying Temperature | 15°C |
Use :- These cables are used for flexible use for medium mechanical stredded with free movement without tensile stress in dry and moist condition for measuring and control in tool machines, conveyor belts, production lines in machinery production, steel production and electrical substations. |
Armoured PVC Control Cable IS:1554(PT-I)-1988 | |||||||||||||
No. of Cores & Cross Sectional Area No. x mm2 | Thickness of PVC Insulation (Nom.) mm | Thickness of Inner sheath (min.) extruded mm | Strip Armoured Cable | Wire Armoured Cable | Current Rating | ||||||||
Strip size mm | Thickness of PVC Outer sheath (Min.) mm | Approx. OD mm | Approx. net weight of cable Kg/km | Round Wire Dia mm | Thickness of PVC Outer sheath (Min.) mm | Approx. OD mm | Approx. Net weight of cable Kg/Km | Standard Delivery Length in Mtrs. | Direct in Ground Amps | In Air / Duct. Amps | |||
2C x 1.5 | 0.8 | 0.3 | – | – | – | – | 1.4 | 1.24 | 13.6 | 415 | 1000 | 23 | 20 |
3C x 1.5 | 0.8 | 0.3 | – | – | – | – | 1.4 | 1.24 | 14.1 | 430 | 1000 | 21 | 17 |
4C x 1.5 | 0.8 | 0.3 | – | – | – | – | 1.4 | 1.24 | 15.0 | 490 | 1000 | 21 | 17 |
5C x 1.5 | 0.8 | 0.3 | – | – | – | – | 1.4 | 1.24 | 15.9 | 545 | 1000 | 16 | 14 |
6C x 1.5 | 0.8 | 0.3 | – | – | – | – | 1.4 | 1.24 | 16.9 | 605 | 1000 | 15 | 13 |
7C x 1.5 | 0.8 | 0.3 | – | – | – | – | 1.4 | 1.24 | 16.9 | 630 | 1000 | 14 | 13 |
10C x 1.5 | 0.8 | 0.3 | – | – | – | – | 1.4 | 1.40 | 20.6 | 835 | 1000 | 13 | 11 |
12C x 1.5 | 0.8 | 0.3 | 4×0.8 | 1.24 | 19.5 | 760 | 1.6 | 1.40 | 21.5 | 950 | 1000 | 12 | 10 |
14C x 1.5 | 0.8 | 0.3 | 4×0.8 | 1.40 | 20.8 | 830 | 1.6 | 1.40 | 22.4 | 1040 | 1000 | 11 | 10 |
16C x 1.5 | 0.8 | 0.3 | 4×0.8 | 1.40 | 21.7 | 920 | 1.6 | 1.40 | 23.3 | 1130 | 1000 | 11 | 9 |
19C x 1.5 | 0.8 | 0.3 | 4×0.8 | 1.40 | 23.1 | 1040 | 1.6 | 1.40 | 24.7 | 1265 | 1000 | 10 | 9 |
24C x 1.5 | 0.8 | 0.3 | 4×0.8 | 1.40 | 26.4 | 1250 | 1.6 | 1.40 | 28.0 | 1510 | 1000 | 9 | 8 |
27C x 1.5 | 0.8 | 0.3 | 4×0.8 | 1.40 | 26.9 | 1355 | 1.6 | 1.40 | 28.5 | 1610 | 1000 | 9 | 8 |
30C x 1.5 | 0.8 | 0.3 | 4×0.8 | 1.40 | 27.8 | 1430 | 1.6 | 1.40 | 29.4 | 1700 | 1000 | 9 | 7 |
37C x 1.5 | 0.8 | 0.3 | 4×0.8 | 1.40 | 29.7 | 1670 | 1.6 | 1.40 | 31.3 | 1960 | 1000 | 8 | 7 |
2C x 2.5 | 0.9 | 0.3 | – | 1.4 | 1.24 | 14.8 | 500 | 1000 | 32 | 27 | |||
3C x 2.5 | 0.9 | 0.3 | – | 1.4 | 1.24 | 15.4 | 520 | 1000 | 27 | 24 | |||
4C x 2.5 | 0.9 | 0.3 | – | 1.4 | 1.24 | 16.4 | 590 | 1000 | 27 | 24 | |||
5C x 2.5 | 0.9 | 0.3 | – | 1.4 | 1.24 | 17.5 | 660 | 1000 | 23 | 19 | |||
6C x 2.5 | 0.9 | 0.3 | – | 1.4 | 1.24 | 18.7 | 745 | 1000 | 21 | 18 | |||
7C x 2.5 | 0.9 | 0.3 | – | 1.4 | 1.24 | 18.7 | 780 | 1000 | 20 | 17 | |||
10C x 2.5 | 0.9 | 0.3 | 4×0.8 | 1.40 | 21.8 | 900 | 1.6 | 1.40 | 23.4 | 1110 | 1000 | 18 | 15 |
12C x 2.5 | 0.9 | 0.3 | 4×0.8 | 1.40 | 22.8 | 1020 | 1.6 | 1.40 | 24.4 | 1240 | 1000 | 17 | 14 |
14C x 2.5 | 0.9 | 0.3 | 4×0.8 | 1.40 | 23.8 | 1130 | 1.6 | 1.40 | 25.4 | 1340 | 1000 | 16 | 13 |
16C x 2.5 | 0.9 | 0.3 | 4×0.8 | 1.40 | 24.9 | 1210 | 1.6 | 1.40 | 26.5 | 1455 | 1000 | 15 | 13 |
19C x 2.5 | 0.9 | 0.3 | 4×0.8 | 1.40 | 26.1 | 1355 | 1.6 | 1.40 | 27.7 | 1605 | 1000 | 14 | 12 |
24C x 2.5 | 0.9 | 0.3 | 4×0.8 | 1.40 | 30.0 | 1655 | 1.6 | 1.56 | 32.0 | 1970 | 1000 | 13 | 11 |
27C x 2.5 | 0.9 | 0.3 | 4×0.8 | 1.40 | 30.6 | 1770 | 1.6 | 1.56 | 32.6 | 2100 | 1000 | 12 | 10 |
30C x 2.5 | 0.9 | 0.3 | 4×0.8 | 1.56 | 32.0 | 1940 | 1.6 | 1.56 | 33.6 | 2250 | 1000 | 12 | 10 |
37C x 2.5 | 0.9 | 0.4 | 4×0.8 | 1.56 | 34.7 | 2300 | 2.0 | 1.56 | 37.1 | 2900 | 1000 | 11 | 9 |
Construction
- Solid / Stranded annealed Copper Conductor & Tinned / Bare
- General Purpose / HR PVC insulation
- Cores Laid up ( filled if needed )
- FRLS / General purpose PVC inner sheath
- Armoring round galvanized steel wires / strips
- FRLS / General purpose PVC outer sheath
Max. Conductor D.C. Resistance at 20°C – Conductor Size
1.5 SQ.MM – 12.1 Ohm / km (Bare) , 12.2 Ohm / km (Tinned)
2.5 sq.mm – 7.41 Ohm / km (Bare), 7.56 Ohm / km (Tinned)
*Dimensions specified are with stranded conductor.
Unarmoured PVC Control Cable IS:1554(Pt-I)-1988 | ||||||||
No. of Cores & Cross Sectional Area No. x mm2 | Thickness of PVC Insulation (Nom.) mm | Thickness of Innersheath (min.) extruded mm | Thickness of Outersheath (nom.) mm | Approx. O.D. Mm | Approx. Net Weight of Cable Kg/Km | Standard Delivery Length in Mtrs. | Current Rating | |
Direct in Ground Amps | In Air / Duct. Amps | |||||||
2C x 1.5 | 0.8 | 0.3 | 1.8 | 11.8 | 185 | 1000 | 23 | 20 |
3C x 1.5 | 0.8 | 0.3 | 1.8 | 12.3 | 190 | 1000 | 21 | 17 |
4C x 1.5 | 0.8 | 0.3 | 1.8 | 13.2 | 225 | 1000 | 21 | 17 |
5C x 1.5 | 0.8 | 0.3 | 1.8 | 14.1 | 260 | 1000 | 16 | 14 |
6C x 1.5 | 0.8 | 0.3 | 1.8 | 15.1 | 295 | 1000 | 15 | 13 |
7C x 1.5 | 0.8 | 0.3 | 1.8 | 15.1 | 315 | 1000 | 14 | 13 |
10C x 1.5 | 0.8 | 0.3 | 1.8 | 18.4 | 425 | 1000 | 13 | 11 |
12C x 1.5 | 0.8 | 0.3 | 1.8 | 18.9 | 480 | 1000 | 12 | 10 |
14C x 1.5 | 0.8 | 0.3 | 1.8 | 19.8 | 535 | 1000 | 11 | 10 |
16C x 1.5 | 0.8 | 0.3 | 1.8 | 20.7 | 595 | 1000 | 11 | 9 |
19C x 1.5 | 0.8 | 0.3 | 2.0 | 22.5 | 720 | 1000 | 10 | 9 |
24C x 1.5 | 0.8 | 0.3 | 2.0 | 25.8 | 880 | 1000 | 9 | 8 |
27C x 1.5 | 0.8 | 0.3 | 2.0 | 26.3 | 960 | 1000 | 9 | 8 |
30C x 1.5 | 0.8 | 0.3 | 2.0 | 27.2 | 1040 | 1000 | 9 | 7 |
37C x 1.5 | 0.8 | 0.3 | 2.0 | 29.1 | 1230 | 1000 | 8 | 7 |
2C x 2.5 | 0.9 | 0.3 | 1.8 | 13.0 | 230 | 1000 | 32 | 27 |
3C x 2.5 | 0.9 | 0.3 | 1.8 | 13.6 | 240 | 1000 | 27 | 24 |
4C x 2.5 | 0.9 | 0.3 | 1.8 | 14.6 | 290 | 1000 | 27 | 24 |
5C x 2.5 | 0.9 | 0.3 | 1.8 | 15.7 | 335 | 1000 | 23 | 19 |
6C x 2.5 | 0.9 | 0.3 | 1.8 | 16.9 | 385 | 1000 | 21 | 18 |
7C x 2.5 | 0.9 | 0.3 | 1.8 | 16.9 | 420 | 1000 | 20 | 17 |
10C x 2.5 | 0.9 | 0.3 | 1.8 | 20.8 | 570 | 1000 | 18 | 15 |
12C x 2.5 | 0.9 | 0.3 | 2.0 | 22.2 | 690 | 1000 | 17 | 14 |
14C x 2.5 | 0.9 | 0.3 | 2.0 | 23.2 | 775 | 1000 | 16 | 13 |
16C x 2.5 | 0.9 | 0.3 | 2.0 | 24.3 | 860 | 1000 | 15 | 13 |
19C x 2.5 | 0.9 | 0.3 | 2.0 | 25.5 | 985 | 1000 | 14 | 12 |
24C x 2.5 | 0.9 | 0.3 | 2.0 | 29.4 | 1215 | 1000 | 13 | 11 |
27C x 2.5 | 0.9 | 0.3 | 2.0 | 30 | 1330 | 1000 | 12 | 10 |
30C x 2.5 | 0.9 | 0.3 | 2.0 | 31 | 1450 | 1000 | 12 | 10 |
37C x 2.5 | 0.9 | 0.4 | 2.2 | 34.1 | 1790 | 1000 | 11 | 9 |
Construction
- Solid / Stranded annealed Copper Conductor & Tinned / Bare
- General Purpose / HR PVC insulation
- Cores Laid up ( filled if needed )
- FRLS / General purpose PVC inner sheath
- FRLS / General purpose PVC Outersheath
Max. Conductor D.C. Resistance at 20°C – Conductor Size
1.5 SQ.MM – 12.1 Ohm / km (Bare) , 12.2 Ohm / km (Tinned)
2.5 sq.mm – 7.41 Ohm / km (Bare), 7.56 Ohm / km (Tinned)
*Dimensions specified are with stranded conductor.
Any other information of pls contact with me:
Vivian Yuan | Sales Director
Zhengzhou Hongda Cable CO., LTD.
Landline: +86 371 6097 5616 | Fax: +86 371 6097 5616
Email: xinyuanyy92(at)gmail.com | Skype ID: xinyuanyy
Cellphone/WhatsApp/Wechat/ICQ: +86 158 3829 0725
Address: Houzhai Industrial Park, Erqi Zone, Zhengzhou, China,450000
We are China XLPE Insulated and PVC Sheathed CY Copper Braid Screened Flexible Control Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: control cable