XLPE 11kV SWA Armoured Electrical Cable Three Cores MV Copper Armoured Cable YJV32

 China XLPE 11kV SWA Armoured Electrical Cable Three Cores MV Copper Armoured Cable YJV32 supplier

XLPE 11kV SWA Armoured Electrical Cable Three Cores MV Copper Armoured Cable YJV32 image

Get a Quote Email to us

Brand Name :
SHANCABLE

Model Number :
YJV32 MV 11kV

Certification :
ISO,CE,IEC,TUV,KEMA

Place of Origin :
Shanghai, China

MOQ :
Negotiable

Price :
Negotiable

Payment Terms :
L/C, T/T

Supply Ability :
100KM/Week

Delivery Time :
10 Days

Packaging Details :
Wooden Drum

Product Model :
MV Armoured Cable

Conductor Material :
Copper

Insulation Material :
XLPE

Armour Type :
SWA

Nos.of Cores :
3

Sheath Material :
PVC

Made Standard :
IEC, BS, IS, VDE

Warranty :
2 years

XLPE 11kV SWA Armoured Electrical Cable Three Cores MV Copper Armoured Cable YJV32

Structure

1 ….. stranded bare copper
2 ….. inner layer of semi-conducting material
3 ….. core insulation of cross-linked polyethylene
4 ….. outer layer of semi-conducting material
5 ….. semi-conducting tape
6 ….. screen of copper wires

7 ….. Fillers strip, Yarn, or Paper
8 ….. Non woven Wrapping tape or Flame Retardant

9 ….. Extruded PVC Inner Covering

10 …. Galvanized Steel Tape Armoured
11 …. Overall Sheath: polyvinylchloride (PVC) or FR-PVC, PE, LSOH

Application

Medium voltage power cable for static application in ground, within and outside facilities, outdoor, in cable canals, in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain.

Due to its very low factor of dielectric loss, which remains constant over its entire operating lifetime, and owing to excellent insulation property of XLPE-material, firmly longitudinally spliced with inner and external screen of semi-conductive material (extruded in one process), the cable has a high operating reliability.

Used in transformer stations, switching blocks, in electric power plants and industrial plants.

To avoid the effects of external impact, the adhering semi-conductive layer extruded between conductor and insulation, along with concentric copper conductor, secures restriction of electric field and resistance to partial discharges.

Standard

International: IEC 60502-2, IEC 60228

China: GB/T 12706.2-2008

Other standards such as BS,DIN and ICEA upon request

Specification

MV(6 to 35kv) Power Cable
Model and Description Uo/U(Um)=3.6/6(7.2), 6/6(7.2), 6/10(12), 8.7/10(12), 8.7/15(17.5), 12/20(24), 18/30(36), 21/35(40.5), 26/35(40.5)kV No.of Core Conductor cross-section area(mm2)
xlpe insulation 1 core 3 core 10 16 25 35 70 95 120 150 185 240 300 400 500 630 sq mm
Cu core Al Core
YJV, N2XSY;PVC sheathed power cable YJLV, NA2XSY; PVC sheathed power cable
YJV22;steel tape armoured,PVC sheathed power cable YJLV22;steel tape armoured,PVC sheathed power cable
YJV32,YJV42;steel wire armoured ,PVC sheathed power cable YJLV32,YJLV42;steel wire armoured ,PVC sheathed power cable
pvc insulation
Cu Core Al Core
VV(VY);PVC(PE)sheathed power cable VLV(VLY);PVC(PE)sheathed power cable
VV22(VV23);steel tape armoured,PVC(PE)sheathed power cable VLV22(VLV23);steel tape armoured,PVC(PE)sheathed power cable
VV32(VV33),VV42(VV43);steel wire armoured ,PVC(PE)sheathed power cable VLV32(VLV33),VLV42(VLV43);steel wire armoured ,PVC(PE)sheathed power cable

Technical data

Maximum Conductor Temperature: under normal (90°C), emergency (130°C) or short circuit no more than 5 s (250°C) conditions.

Min. Ambient Temp. 0°C, after installation and only when cable is in a fixed position

Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables

15 x cable O.D for single-core armoured cables

15 x cable O.D for multi-core non-armoured cables

12 x cable O.D for multi-core armoured cables

Certificate

ISO,CE, KEMA ,IEC, RoHS, CCC, P3C and more others at request

Ordering

Rated Voltage

Application Standard:IEC/BS/UL/GB

Number of Cores

Conductor Size $ Construction

Type of Insulation

Armored or unarmored. If armour, the armour type & material

The Requirement of Sheath

Length of Cable & Packing Requirement

Other Requirement

Technical Parameter

Nom. Cross-section of conductor Strands No./Dia. Of Conductor Insulation Thickness Inner Sheath Thickness Dia. Of Armor Wire Sheath Thickness Approx. O.D. Approx.Weight Max. D.C Resistance of Conductor (20 ℃) Testing Voltage A.C Current Rating
mm2 pc/mm mm mm mm mm (mm) kg/km Ω /km kV/5min In air (A) In soil(A)
3 × 25 7/2.14 3.4 1.3 2.5 2.5 49.0 4579 0.727 21 120 125
3 × 35 7/2.52 3.4 1.3 2.5 2.6 52.0 5097 0.524 21 140 155
3 × 50 10/2.52 3.4 1.4 2.5 2.7 54.0 5802 0.387 21 165 180
3 × 70 14/2.52 3.4 1.5 2.5 2.8 58.0 6788 0.268 21 210 220
3 × 95 19/2.52 3.4 1.5 2.5 2.9 62.0 7812 0.193 21 255 265
3 × 120 24/2.52 3.4 1.6 2.5 3.1 65.0 8929 0.153 21 290 300
3 × 150 30/2.52 3.4 1.7 2.5 3.2 68.0 10125 0.124 21 330 340
3 × 185 37/2.52 3.4 1.7 3.15 3.3 72.0 12403 0.0991 21 375 380
3 × 240 48/2.52 3.4 1.8 3.15 3.5 78.0 14646 0.0754 21 435 435
3 × 300 61/2.52 3.4 1.9 3.15 3.7 83.0 17014 0.0601 21 495 485

This product is applicable to the power transmission and distribution line with AC rated voltage(U0/U) of 3.6/6kV-26/36kV system.It is routed in air (cable bridge frame,indoor wall support,and tray) and soil(direct buried, cable trench,pipe ect.) respectively according to difference of the protection layer structure.