Underground MV power cable with cu/XLPE/CTS/LSOH/STA/LSOH rated voltage 12/20kV
Underground MV power cable with cu/XLPE/CTS/LSOH/STA/LSOH rated voltage 12/20kV image
Brand Name :
CHINT
Model Number :
LSZH(WDZR-YJY22)
Certification :
CE/SGS/KEMA
Place of Origin :
CHINA
MOQ :
Negotiable
Price :
Negotiable
Supply Ability :
500km/month
Packaging Details :
Wooden drum/iorn drum
Filler :
PP or FR-PP
Core :
1 OR 3
Laying :
Tunnel or directly buried
Standard :
IEC60502.2 IEC60332-3 or IEC60754
Metallic screen :
CTS or CWS
Armor :
Double steel tape
Underground MV power cable with cu/XLPE/CTS/LSOH/STA/LSOH rated voltage 12/20kV
Detailed Product Description
Standards
International: IEC 60502, IEC 60228, IEC 60332, IEC 60754
China: GB∕T 12706.2-2008, GB∕T 19666-2005
Other standards such as BS,VDE and ICEA upon request
Note:
Insulation identification as per standards or customer requirement
Applications
Laying in room ,tunnel ,cable trench ,and pipes.
Constructions
Conductor : Compact stranded copper conductor, Cl.2 as per IEC 60228
Conductor Screen: Semi-conductor
Insulation : XLPE(cross-linked polyethylene) rated at 90 ℃
Insulation Screen: Semi-conductor
Screen : Copper tape
Interlining: LSOH Flame Retardant Polyolefin, black
Armouring: STA(Steel-Tape Armouring)
Sheath : LSOH Flame Retardant Polyolefin, black
Technical data
Rated voltage: 12/20 kV
Maximum Conductor Temperature: under normal (90 ℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions.
Min. Ambient Temp.: The cable shall be pre heated if the ambient temperature is below 0℃
Min. Bending Radius: single core cable 20(d+D)±5%
Multi-core cable 15(d+D)±5%
Certificates
CE, SGS, KEMA and more others at request
Technical Specifications
Nom. Cross-section of conductor | Strands No./Dia. Of Conductor | Insulation Thickness |
Thickness of Copper Strip | Thickness of steel tape | Sheath Thickness | Approx. O.D. | Approx. | Max. D.C Resistance of Conductor (20 ℃) | Testing Voltage A.C | Current Rating | |
Weight | In air (A) | In soil(A) | |||||||||
1×35 | 7/2.56+0.01 | 5.5 | 0.12 | 0.2 | 1.9 | 29.3 | 1238 | 0.524 | 48 | 205 | 190 |
1×50 | 19/1.86+0.01 | 5.5 | 0.12 | 0.2 | 1.9 | 30.6 | 1408 | 0.387 | 48 | 245 | 225 |
1×70 | 14/2.56+0.01 | 5.5 | 0.12 | 0.2 | 2.0 | 32.5 | 1685 | 0.268 | 48 | 305 | 275 |
1×95 | 19/2.56+0.02 | 5.5 | 0.12 | 0.2 | 2.0 | 34.1 | 1994 | 0.193 | 48 | 370 | 330 |
1×120 | 24/2.56+0.02 | 5.5 | 0.12 | 0.2 | 2.1 | 35.8 | 2295 | 0.153 | 48 | 430 | 375 |
1×150 | 30/2.56+0.01 | 5.5 | 0.12 | 0.5 | 2.1 | 39.0 | 2993 | 0.124 | 48 | 490 | 425 |
1×185 | 37/2.56+0.02 | 5.5 | 0.12 | 0.5 | 2.2 | 41.0 | 3459 | 0.0991 | 48 | 560 | 480 |
1×240 | 48/2.58+0.02 | 5.5 | 0.12 | 0.5 | 2.3 | 43.4 | 4121 | 0.0754 | 48 | 665 | 555 |
1×300 | 60/2.58+0.02 | 5.5 | 0.12 | 0.5 | 2.4 | 46.0 | 4830 | 0.0601 | 48 | 765 | 630 |
1×400 | 60/2.93+0.02 | 5.5 | 0.12 | 0.5 | 2.5 | 49.1 | 5830 | 0.047 | 48 | 890 | 725 |
1×500 | 60/3.33+0.02 | 5.5 | 0.12 | 0.5 | 2.6 | 52.7 | 7105 | 0.0366 | 48 | 1030 | 825 |
1×630 | 60/3.76+0.02 | 5.5 | 0.12 | 0.5 | 2.7 | 56.5 | 8603 | 0.0283 | 48 | 1200 | 950 |
3×35 | 7/2.56+0.01 | 5.5 | 0.10 | 0.5 | 2.8 | 58.7 | 4640 | 0.524 | 48 | 140 | 155 |
3×50 | 19/1.86+0.01 | 5.5 | 0.10 | 0.5 | 2.9 | 62.3 | 5326 | 0.387 | 48 | 165 | 180 |
3×70 | 14/2.56+0.01 | 5.5 | 0.10 | 0.5 | 3.0 | 66.2 | 6263 | 0.268 | 48 | 210 | 220 |
3×95 | 19/2.56+0.02 | 5.5 | 0.10 | 0.5 | 3.1 | 70.0 | 7369 | 0.193 | 48 | 255 | 265 |
3×120 | 24/2.56+0.02 | 5.5 | 0.10 | 0.5 | 3.2 | 73.7 | 8410 | 0.153 | 48 | 290 | 300 |
3×150 | 30/2.56+0.01 | 5.5 | 0.10 | 0.5 | 3.3 | 76.9 | 9484 | 0.124 | 48 | 330 | 340 |
3×185 | 37/2.56+0.02 | 5.5 | 0.10 | 0.5 | 3.5 | 81.4 | 11029 | 0.0991 | 48 | 375 | 380 |
3×240 | 48/2.58+0.02 | 5.5 | 0.10 | 0.8 | 3.7 | 87.9 | 14030 | 0.0754 | 48 | 435 | 435 |
3×300 | 60/2.58+0.02 | 5.5 | 0.10 | 0.8 | 3.8 | 93.0 | 16303 | 0.0601 | 48 | 493 | 485 |
3×400 | 60/2.93+0.02 | 5.5 | 0.10 | 0.8 | 4.1 | 100.1 | 19672 | 0.047 | 48 | 565 | 520 |
Ordering Advice
Rated Voltage
Application Standard: IEC/BS/UL/GB
Number of Cores
Conductor Size & Construction
Type of Insulation
Armored or unarmored. If armor, the armor type & material
The Requirement of Sheath
Length of Cable & Packing Requirement
Other Requirement
PACKING AND SHIPPING
We are capable of meeting the strictest delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self-adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.
Product photo
We are China Underground MV power cable with cu/XLPE/CTS/LSOH/STA/LSOH rated voltage 12/20kV manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: flame retardant low smoke cables, Low Smoke Zero Halogen Power Cable, lszh power cables