Type SHD-GC Special Cables EPR Insulated And CPE / TPU Jacket Heat Resistant
Type SHD-GC Special Cables EPR Insulated And CPE / TPU Jacket Heat Resistant image
Type SHD-GC Special Cables EPR Insulated And CPE / TPU Jacket Heat Resistant
APPLICATION
CHARACTERISTIC
1. Phase, Grounding Conductors, Ground check conductors: Soft or annealed tinned coated copper
2. Conductor Shield: A helically applied semiconducting tape.
Insulation: High quality, heat, moisture, ozone and thermosetting ethylene propylene rubber (EPR)
Insulation Shield: An overlapped semiconducting tape shall be applied over the insulation.
Metallic Component: A composite fiber-copper braid shield, tinned coated copper wires, Coverage
Assembly: Phase, ground check and grounding conductors cabled together with hygroscopic fillers and a
7. Ground Check: Polypropylene insulation yellow colored for identification.
8. Jacket(CPE): Heavy duty or extra heavy duty chlorinated polyethylene (CPE) compound, applied in one
8. Jacket(TPU): Extra heavy duty, high torsion resistant, integral-filled, thermoplastic Polyurethane jacket,
Technical Data
SHD-GC 2 kV | |||||||||
Selection data | |||||||||
Power | Power conductor | Nominal | Jacket | Grounding conductor | Approximate overall | Ampacity | |||
Size | Stranding | ||||||||
AWG or MCM | Inches | Inches | AWG | Inches | A | ||||
6 | 133 | 7×19 | 0.070 | 0.155 | 10 | 49 | 7×7 | 1.26 | 93 |
4 | 259 | 7×37 | 0.070 | 0.155 | 8 | 133 | 7×19 | 1.36 | 122 |
2 | 259 | 7×37 | 0.070 | 0.170 | 6 | 133 | 7×19 | 1.55 | 159 |
1 | 259 | 7×37 | 0.080 | 0.170 | 5 | 133 | 7×19 | 1.71 | 184 |
1/0 | 266 | 19×14 | 0.080 | 0.190 | 4 | 259 | 7×37 | 1.81 | 211 |
2/0 | 342 | 19×18 | 0.080 | 0.205 | 3 | 259 | 7×39 | 1.94 | 243 |
3/0 | 418 | 19×22 | 0.080 | 0.205 | 2 | 259 | 7×37 | 2.07 | 279 |
4/0 | 532 | 19×28 | 0.080 | 0.220 | 1 | 259 | 7×37 | 2.24 | 321 |
250 | 627 | 19×33 | 0.095 | 0.220 | 1/0 | 266 | 19×14 | 2.44 | 355 |
300 | 740 | 37×20 | 0.095 | 0.235 | 1/0 | 266 | 19×14 | 2.70 | 395 |
350 | 888 | 37×24 | 0.095 | 0.235 | 2/0 | 342 | 19×18 | 2.73 | 435 |
500 | 1221 | 37×33 | 0.095 | 0.265 | 4/0 | 532 | 19×28 | 3.10 | 536 |
SHD-GC 5 kV | |||||||||
Selection data | |||||||||
Power | Power conductor | Nominal | Jacket | Grounding conductor | Approximate overall | Ampacity | |||
Size | Stranding | ||||||||
AWG or MCM | Inches | Inches | AWG | Inches | A | ||||
6 | 133 | 7×19 | 0.110 | 0.185 | 10 | 49 | 7×7 | 1.51 | 93 |
4 | 259 | 7×37 | 0.110 | 0.185 | 8 | 133 | 7×19 | 1.60 | 122 |
2 | 259 | 7×37 | 0.110 | 0.205 | 6 | 133 | 7×19 | 1.79 | 159 |
1 | 259 | 7×37 | 0.110 | 0.205 | 5 | 133 | 7×19 | 1.88 | 184 |
1/0 | 266 | 19×14 | 0.110 | 0.220 | 4 | 259 | 7×37 | 1.98 | 211 |
2/0 | 342 | 19×18 | 0.110 | 0.220 | 3 | 259 | 7×37 | 2.12 | 243 |
3/0 | 418 | 19×22 | 0.110 | 0.235 | 2 | 259 | 7×37 | 2.26 | 279 |
4/0 | 532 | 19×28 | 0.110 | 0.235 | 1 | 259 | 7×37 | 2.51 | 321 |
250 | 627 | 19×33 | 0.120 | 0.250 | 1/0 | 266 | 19×14 | 2.57 | 355 |
350 | 888 | 37×24 | 0.120 | 0.265 | 2/0 | 342 | 19×18 | 2.83 | 435 |
500 | 1221 | 37×33 | 0.120 | 0.280 | 4/0 | 532 | 19×28 | 3.18 | 536 |
SHD-GC 8 kV | |||||||||
Selection data | |||||||||
Power | Power conductor | Nominal | Jacket | Grounding conductor | Approximate overall | Ampacity | |||
Size | Stranding | ||||||||
AWG or MCM | Inches | Inches | AWG | Inches | A | ||||
4 | 259 | 7×37 | 0.150 | 0.205 | 8 | 133 | 7×19 | 1.93 | 93 |
2 | 259 | 7×37 | 0.150 | 0.220 | 6 | 133 | 7×19 | 2.02 | 122 |
1 | 259 | 7×37 | 0.150 | 0.220 | 5 | 133 | 7×19 | 2.10 | 159 |
1/0 | 266 | 19×14 | 0.150 | 0.220 | 4 | 259 | 7×37 | 2.21 | 184 |
2/0 | 342 | 19×18 | 0.150 | 0.235 | 3 | 259 | 7×37 | 2.34 | 211 |
3/0 | 418 | 19×22 | 0.150 | 0.250 | 2 | 259 | 7×37 | 4.49 | 243 |
4/0 | 532 | 19×28 | 0.150 | 0.250 | 1 | 259 | 7×37 | 2.63 | 279 |
250 | 627 | 19×33 | 0.150 | 0.250 | 1/0 | 266 | 19×14 | 2.75 | 321 |
350 | 888 | 37×24 | 0.150 | 0.280 | 2/0 | 342 | 19×18 | 3.05 | 355 |
500 | 1221 | 37×33 | 0.150 | 0.295 | 4/0 | 532 | 19×28 | 3.39 | 435 |
SHD-GC 15 kV | |||||||||
Selection data | |||||||||
Power | Power conductor | Nominal | Jacket | Grounding conductor | Approximate overall | Ampacity | |||
Size | Stranding | ||||||||
AWG or MCM | Inches | Inches | AWG | Inches | A | ||||
2 | 259 | 7×37 | 0.210 | 0.235 | 6 | 133 | 7×19 | 2.31 | 164 |
1 | 259 | 7×37 | 0.210 | 0.235 | 5 | 133 | 7×19 | 2.40 | 187 |
1/0 | 266 | 19×14 | 0.210 | 0.250 | 4 | 259 | 7×37 | 2.52 | 215 |
2/0 | 342 | 19×18 | 0.210 | 0.250 | 3 | 259 | 7×37 | 2.60 | 246 |
3/0 | 418 | 19×22 | 0.210 | 0.265 | 2 | 259 | 7×37 | 2.79 | 283 |
4/0 | 532 | 19×28 | 0.210 | 0.265 | 1 | 259 | 7×37 | 2.90 | 325 |
250* | 627 | 19×33 | 0.210 | 0.265 | 1/0 | 266 | 19×14 | 3.05 | 355 |
350* | 888 | 37×24 | 0.210 | 0.280 | 2/0 | 342 | 19×18 | 3.31 | 435 |
500* | 1221 | 37×33 | 0.210 | 0.295 | 4/0 | 532 | 19×28 | 3.72 | 536 |
SHD-GC 25 kV | |||||||||
Selection data | |||||||||
Power | Power conductor | Nominal | Jacket | Grounding conductor | Approximate overall | Ampacity | |||
Size | Stranding | ||||||||
AWG or MCM | Inches | Inches | AWG | Inches | A | ||||
2 | 259 | 7×37 | 0.295 | 0.235 | 6 | 133 | 7×19 | 2.55 | 178 |
1 | 259 | 7×37 | 0.295 | 0.265 | 5 | 133 | 7×19 | 2.86 | 191 |
1/0 | 266 | 19×14 | 0.295 | 0.265 | 4 | 259 | 7×37 | 2.91 | 218 |
2/0 | 342 | 19×18 | 0.295 | 0.280 | 3 | 259 | 7×37 | 3.06 | 249 |
3/0 | 418 | 19X22 | 0.295 | 0.280 | 2 | 259 | 7×37 | 3.19 | 286 |
4/0 | 532 | 19×28 | 0.295 | 0.295 | 1 | 259 | 7×37 | 3.34 | 327 |
250* | 627 | 19×33 | 0.295 | 0.295 | 1/0 | 266 | 19×14 | 3.43 | 360 |
350* | 888 | 37×24 | 0.295 | 0.295 | 2/0 | 342 | 19×18 | 3.66 | 435 |
We are China Type SHD-GC Special Cables EPR Insulated And CPE / TPU Jacket Heat Resistant manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: copper welding cable, Special Cables, special power cable