Type SHD-GC Special Cables EPR Insulated And CPE / TPU Jacket Heat Resistant

 China Type SHD-GC Special Cables EPR Insulated And CPE / TPU Jacket Heat Resistant supplier

Type SHD-GC Special Cables EPR Insulated And CPE / TPU Jacket Heat Resistant image

Get a Quote Email to us

Model Number :SHD-GC
Certification :CE
Place of Origin :Henan
MOQ :500meters
Payment Terms :L/C, T/T
Delivery Time :30days after payment
Packaging Details :Iron-wooden drum
Phase, Grounding Conductors, Ground check conductors :Soft or annealed tinned coated copper
Conductor Shield :A helically applied semiconducting tape
Insulation :EPR
Insulation Shield :An overlapped semiconducting tape shall be applied over the insulation.
Metallic Component :A composite fiber-copper braid shield, tinned coated copper wires, Coverage
Assembly :Phase, ground check and grounding conductors cabled together with hygroscopic fillers and a
Ground Check :Polypropylene insulation yellow colored for identification
Jacket :CPE

Type SHD-GC Special Cables EPR Insulated And CPE / TPU Jacket Heat Resistant

 

APPLICATION
CHARACTERISTIC

 

 

1. Phase, Grounding Conductors, Ground check conductors: Soft or annealed tinned coated copper
2. Conductor Shield: A helically applied semiconducting tape.
Insulation: High quality, heat, moisture, ozone and thermosetting ethylene propylene rubber (EPR)
Insulation Shield: An overlapped semiconducting tape shall be applied over the insulation.
Metallic Component: A composite fiber-copper braid shield, tinned coated copper wires, Coverage
Assembly: Phase, ground check and grounding conductors cabled together with hygroscopic fillers and a
7. Ground Check: Polypropylene insulation yellow colored for identification.
8. Jacket(CPE): Heavy duty or extra heavy duty chlorinated polyethylene (CPE) compound, applied in one
8. Jacket(TPU): Extra heavy duty, high torsion resistant, integral-filled, thermoplastic Polyurethane jacket,

 

Technical Data

SHD-GC 2 kV
Selection data
Power Power conductor Nominal Jacket Grounding conductor Approximate overall Ampacity
Size Stranding
AWG or MCM   Inches Inches AWG   Inches A
6 133 7×19 0.070 0.155 10 49 7×7 1.26 93
4 259 7×37 0.070 0.155 8 133 7×19 1.36 122
2 259 7×37 0.070 0.170 6 133 7×19 1.55 159
1 259 7×37 0.080 0.170 5 133 7×19 1.71 184
1/0 266 19×14 0.080 0.190 4 259 7×37 1.81 211
2/0 342 19×18 0.080 0.205 3 259 7×39 1.94 243
3/0 418 19×22 0.080 0.205 2 259 7×37 2.07 279
4/0 532 19×28 0.080 0.220 1 259 7×37 2.24 321
250 627 19×33 0.095 0.220 1/0 266 19×14 2.44 355
300 740 37×20 0.095 0.235 1/0 266 19×14 2.70 395
350 888 37×24 0.095 0.235 2/0 342 19×18 2.73 435
500 1221 37×33 0.095 0.265 4/0 532 19×28 3.10 536

 

SHD-GC 5 kV
Selection data
Power Power conductor Nominal Jacket Grounding conductor Approximate overall Ampacity
Size Stranding
AWG or MCM   Inches Inches AWG   Inches A
6 133 7×19 0.110 0.185 10 49 7×7 1.51 93
4 259 7×37 0.110 0.185 8 133 7×19 1.60 122
2 259 7×37 0.110 0.205 6 133 7×19 1.79 159
1 259 7×37 0.110 0.205 5 133 7×19 1.88 184
1/0 266 19×14 0.110 0.220 4 259 7×37 1.98 211
2/0 342 19×18 0.110 0.220 3 259 7×37 2.12 243
3/0 418 19×22 0.110 0.235 2 259 7×37 2.26 279
4/0 532 19×28 0.110 0.235 1 259 7×37 2.51 321
250 627 19×33 0.120 0.250 1/0 266 19×14 2.57 355
350 888 37×24 0.120 0.265 2/0 342 19×18 2.83 435
500 1221 37×33 0.120 0.280 4/0 532 19×28 3.18 536

 

SHD-GC 8 kV
Selection data
Power Power conductor Nominal Jacket Grounding conductor Approximate overall Ampacity
Size Stranding
AWG or MCM   Inches Inches AWG   Inches A
4 259 7×37 0.150 0.205 8 133 7×19 1.93 93
2 259 7×37 0.150 0.220 6 133 7×19 2.02 122
1 259 7×37 0.150 0.220 5 133 7×19 2.10 159
1/0 266 19×14 0.150 0.220 4 259 7×37 2.21 184
2/0 342 19×18 0.150 0.235 3 259 7×37 2.34 211
3/0 418 19×22 0.150 0.250 2 259 7×37 4.49 243
4/0 532 19×28 0.150 0.250 1 259 7×37 2.63 279
250 627 19×33 0.150 0.250 1/0 266 19×14 2.75 321
350 888 37×24 0.150 0.280 2/0 342 19×18 3.05 355
500 1221 37×33 0.150 0.295 4/0 532 19×28 3.39 435

 

SHD-GC 15 kV
Selection data
Power Power conductor Nominal Jacket Grounding conductor Approximate overall Ampacity
Size Stranding
AWG or MCM   Inches Inches AWG   Inches A
2 259 7×37 0.210 0.235 6 133 7×19 2.31 164
1 259 7×37 0.210 0.235 5 133 7×19 2.40 187
1/0 266 19×14 0.210 0.250 4 259 7×37 2.52 215
2/0 342 19×18 0.210 0.250 3 259 7×37 2.60 246
3/0 418 19×22 0.210 0.265 2 259 7×37 2.79 283
4/0 532 19×28 0.210 0.265 1 259 7×37 2.90 325
250* 627 19×33 0.210 0.265 1/0 266 19×14 3.05 355
350* 888 37×24 0.210 0.280 2/0 342 19×18 3.31 435
500* 1221 37×33 0.210 0.295 4/0 532 19×28 3.72 536

 

SHD-GC 25 kV
Selection data
Power Power conductor Nominal Jacket Grounding conductor Approximate overall Ampacity
Size Stranding
AWG or MCM   Inches Inches AWG   Inches A
2 259 7×37 0.295 0.235 6 133 7×19 2.55 178
1 259 7×37 0.295 0.265 5 133 7×19 2.86 191
1/0 266 19×14 0.295 0.265 4 259 7×37 2.91 218
2/0 342 19×18 0.295 0.280 3 259 7×37 3.06 249
3/0 418 19X22 0.295 0.280 2 259 7×37 3.19 286
4/0 532 19×28 0.295 0.295 1 259 7×37 3.34 327
250* 627 19×33 0.295 0.295 1/0 266 19×14 3.43 360
350* 888 37×24 0.295 0.295 2/0 342 19×18 3.66 435

 

We are China Type SHD-GC Special Cables EPR Insulated And CPE / TPU Jacket Heat Resistant manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.