Type SHD-GC Special Cables EPR Insulated And CPE / TPU Jacket Heat Resistant

 China Type SHD-GC Special Cables EPR Insulated And CPE / TPU Jacket Heat Resistant supplier

Type SHD-GC Special Cables EPR Insulated And CPE / TPU Jacket Heat Resistant image

Get a Quote Email to us

Brand Name :
CN CABLE

Model Number :
SHD-GC

Certification :
CE

Place of Origin :
Henan

MOQ :
500meters

Payment Terms :
L/C, T/T

Delivery Time :
30days after payment

Packaging Details :
Iron-wooden drum

Phase, Grounding Conductors, Ground check conductors :
Soft or annealed tinned coated copper

Conductor Shield :
A helically applied semiconducting tape

Insulation :
EPR

Insulation Shield :
An overlapped semiconducting tape shall be applied over the insulation.

Metallic Component :
A composite fiber-copper braid shield, tinned coated copper wires, Coverage

Assembly :
Phase, ground check and grounding conductors cabled together with hygroscopic fillers and a

Ground Check :
Polypropylene insulation yellow colored for identification

Jacket :
CPE

Type SHD-GC Special Cables EPR Insulated And CPE / TPU Jacket Heat Resistant

APPLICATION
Trailing cable on ac mining equipment where service conditions are severe and maximum safety is mandatory; such as
power shovels and drag lines in open-pit mines, quarries, gantry cranes and slag reclaiming.
Used for high voltage distribution in underground mines where frequent relocation is necessary or where extra
flexibility and toughness is desired.
Meets all requirements of ICEA S-75-381.
CHARACTERISTIC
Excellent flexibility
Highly ozone, sun, weather and flame resistant
Excellent impact and abrasion resistant
Rated and flexible at -500C
Oil and heat resistant

1. Phase, Grounding Conductors, Ground check conductors: Soft or annealed tinned coated copper
conductor, rope lay flexible stranding per ASTM B172
2. Conductor Shield: A helically applied semiconducting tape.
3. Insulation: High quality, heat, moisture, ozone and thermosetting ethylene propylene rubber (EPR)
meeting ICEA.
4. Insulation Shield: An overlapped semiconducting tape shall be applied over the insulation.
5. Metallic Component: A composite fiber-copper braid shield, tinned coated copper wires, Coverage
minimum 60 ,with colored fibers for phase identification (black, white, red).
6. Assembly: Phase, ground check and grounding conductors cabled together with hygroscopic fillers and a
binder tape.
7. Ground Check: Polypropylene insulation yellow colored for identification.
8. Jacket(CPE): Heavy duty or extra heavy duty chlorinated polyethylene (CPE) compound, applied in one
layer over a fibrous reinforcement layer, Black or other colors can be provided.
8. Jacket(TPU): Extra heavy duty, high torsion resistant, integral-filled, thermoplastic Polyurethane jacket,
Black or other colors can be provided.

Technical Data

SHD-GC 2 kV
Selection data
Power
conductor size
Power conductor
stranding
Nominal
thickness of
insulation
Jacket
thickness
Grounding conductor Approximate overall
diameter
Ampacity
40°Cambient
temperature
Size Stranding
AWG or MCM Inches Inches AWG Inches A
6 133 7×19 0.070 0.155 10 49 7×7 1.26 93
4 259 7×37 0.070 0.155 8 133 7×19 1.36 122
2 259 7×37 0.070 0.170 6 133 7×19 1.55 159
1 259 7×37 0.080 0.170 5 133 7×19 1.71 184
1/0 266 19×14 0.080 0.190 4 259 7×37 1.81 211
2/0 342 19×18 0.080 0.205 3 259 7×39 1.94 243
3/0 418 19×22 0.080 0.205 2 259 7×37 2.07 279
4/0 532 19×28 0.080 0.220 1 259 7×37 2.24 321
250 627 19×33 0.095 0.220 1/0 266 19×14 2.44 355
300 740 37×20 0.095 0.235 1/0 266 19×14 2.70 395
350 888 37×24 0.095 0.235 2/0 342 19×18 2.73 435
500 1221 37×33 0.095 0.265 4/0 532 19×28 3.10 536

SHD-GC 5 kV
Selection data
Power
conductor size
Power conductor
stranding
Nominal
thickness of
insulation
Jacket
thickness
Grounding conductor Approximate overall
diameter
Ampacity
40°Cambient
temperature
Size Stranding
AWG or MCM Inches Inches AWG Inches A
6 133 7×19 0.110 0.185 10 49 7×7 1.51 93
4 259 7×37 0.110 0.185 8 133 7×19 1.60 122
2 259 7×37 0.110 0.205 6 133 7×19 1.79 159
1 259 7×37 0.110 0.205 5 133 7×19 1.88 184
1/0 266 19×14 0.110 0.220 4 259 7×37 1.98 211
2/0 342 19×18 0.110 0.220 3 259 7×37 2.12 243
3/0 418 19×22 0.110 0.235 2 259 7×37 2.26 279
4/0 532 19×28 0.110 0.235 1 259 7×37 2.51 321
250 627 19×33 0.120 0.250 1/0 266 19×14 2.57 355
350 888 37×24 0.120 0.265 2/0 342 19×18 2.83 435
500 1221 37×33 0.120 0.280 4/0 532 19×28 3.18 536

SHD-GC 8 kV
Selection data
Power
conductor size
Power conductor
stranding
Nominal
thickness of
insulation
Jacket
thickness
Grounding conductor Approximate overall
diameter
Ampacity
40°Cambient
temperature
Size Stranding
AWG or MCM Inches Inches AWG Inches A
4 259 7×37 0.150 0.205 8 133 7×19 1.93 93
2 259 7×37 0.150 0.220 6 133 7×19 2.02 122
1 259 7×37 0.150 0.220 5 133 7×19 2.10 159
1/0 266 19×14 0.150 0.220 4 259 7×37 2.21 184
2/0 342 19×18 0.150 0.235 3 259 7×37 2.34 211
3/0 418 19×22 0.150 0.250 2 259 7×37 4.49 243
4/0 532 19×28 0.150 0.250 1 259 7×37 2.63 279
250 627 19×33 0.150 0.250 1/0 266 19×14 2.75 321
350 888 37×24 0.150 0.280 2/0 342 19×18 3.05 355
500 1221 37×33 0.150 0.295 4/0 532 19×28 3.39 435

SHD-GC 15 kV
Selection data
Power
conductor size
Power conductor
stranding
Nominal
thickness of
insulation
Jacket
thickness
Grounding conductor Approximate overall
diameter
Ampacity
40°Cambient
temperature
Size Stranding
AWG or MCM Inches Inches AWG Inches A
2 259 7×37 0.210 0.235 6 133 7×19 2.31 164
1 259 7×37 0.210 0.235 5 133 7×19 2.40 187
1/0 266 19×14 0.210 0.250 4 259 7×37 2.52 215
2/0 342 19×18 0.210 0.250 3 259 7×37 2.60 246
3/0 418 19×22 0.210 0.265 2 259 7×37 2.79 283
4/0 532 19×28 0.210 0.265 1 259 7×37 2.90 325
250* 627 19×33 0.210 0.265 1/0 266 19×14 3.05 355
350* 888 37×24 0.210 0.280 2/0 342 19×18 3.31 435
500* 1221 37×33 0.210 0.295 4/0 532 19×28 3.72 536

SHD-GC 25 kV
Selection data
Power
conductor size
Power conductor
stranding
Nominal
thickness of
insulation
Jacket
thickness
Grounding conductor Approximate overall
diameter
Ampacity
40°Cambient
temperature
Size Stranding
AWG or MCM Inches Inches AWG Inches A
2 259 7×37 0.295 0.235 6 133 7×19 2.55 178
1 259 7×37 0.295 0.265 5 133 7×19 2.86 191
1/0 266 19×14 0.295 0.265 4 259 7×37 2.91 218
2/0 342 19×18 0.295 0.280 3 259 7×37 3.06 249
3/0 418 19X22 0.295 0.280 2 259 7×37 3.19 286
4/0 532 19×28 0.295 0.295 1 259 7×37 3.34 327
250* 627 19×33 0.295 0.295 1/0 266 19×14 3.43 360
350* 888 37×24 0.295 0.295 2/0 342 19×18 3.66 435

We are China Type SHD-GC Special Cables EPR Insulated And CPE / TPU Jacket Heat Resistant manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION