Stranded Aluminum Conductor XLPE ABC Aerial Bundle Cable

 China Stranded Aluminum Conductor XLPE ABC Aerial Bundle Cable supplier

Stranded Aluminum Conductor XLPE ABC Aerial Bundle Cable image

Get a Quote Email to us

Brand Name :
Zhenglan Cable

Model Number :
Aerial Insulated Cable

Certification :
3C,ISO 9001:2015,ISO 14001:2005; CE

Place of Origin :
Henan, China

MOQ :
Negotiable

Price :
Negotiable

Payment Terms :
T/T, L/C, Western Union

Supply Ability :
100Km/Month

Delivery Time :
15-30 days

Packaging Details :
Wooden drum, wooden-steel drum, coil or plastic drum or customized

Name :
Aerial Bundled Cables

Insulation Material :
XLPE

Conductor Material :
Aluminum

Application :
Overhead

Standard :
ASTM

structure :
AL/XLPE

Color :
Black

Running Voltage :
0.6/1kV

Durable Aerial Bundle Cable Stranded Aluminum Conductor with XLPE Insulation ABC Cable

Application

Covered line wire

Covered line wire is used primarily for overhead secondary distribution lines.It is not an electrically insulated conductor and is treated as bare conductor when installed.

Duplex service drop

To supply 120 volt aerial service for temporary service at construction sites,outdoorr or street lighting.For service at 600 volts or lower ar a conductor temperature of 75 °Cmaximum.

Triplex service drop

To supply power from the utility’s lines to the consumer’s weatherhead.For service at 600 volts or less (pahse to phase) at a conductor temperature of 75°Cmaximum for polyethylene insulation or 90°C maximum for crosslinked insulation.

Quadruplex service drop

Used to supply 3 phase power,usually from a pole-mounted transformer,to the user’s service head where connection to the service entrance cable is made.To be used at voltage of 600 volts or less phase to phase and at conductor temperature no to exceed 75°C for polyethylene insulated conductor or 90°C for crosslinked polyethylene insulated conductors.

Specification Data

Nominal Area Number /Dia. Insulation Thickness Dcresistance PHASE NEUTRAL Rated Strength kn Delivery Lerngth
mm2 mm mm & Ω /km AAC AAAC km
1×16+16 7/1.70 1.3 1.7986 3.02 4.69 10
2×16+16 7/1.70 1.3 1.7986 3.02 4.69 7.5
3×16+16 7/1.70 1.3 1.7986 3.02 4.69 5
4×16 7/1.70 1.3 1.7986 3.02 4.69 5
1×25+25 7/2.10 1.3 1.1787 4.36 7.15 6.5
2×25+25 7/2.10 1.3 1.1787 4.36 7.15 5
3×25+25 7/2.10 1.3 1.1787 4.36 7.15 3.2
4×25 7/2.10 1.3 1.1787 4.36 7.15 3.2
1×35+35 7/2.50 1.3 0.8317 6.01 10.14 4.5
2×35+35 7/2.50 1.3 0.8317 6.01 10.14 3.5
3×35+35 7/2.50 1.3 0.8317 6.01 10.14 2.2
4×35 7/2.50 1.3 0.8317 6.01 10.14 2.2
1×50+50 7/3.0 1.5 0.5776 8.41 14.6 3
3×50+50 7/3.0 1.5 0.5776 8.41 14.6 1.3
1×70+70 19/2.10 1.5 0.4367 11.85 19.41 2.2
3×70+70 19/2.10 1.5 0.4367 11.85 19.41 0.8
3×95+95 19/2.50 1.6 0.3081 16.32 27.51 0.5
Code Word

3×25mm2+

1×54.6mm2

3×35mm2+

1×54.6mm2

3×50mm2+

1×54.6mm2

3×70mm2+

1×54.6mm2

3×35mm2+

1×54.6mm2+1×16mm2

3×70mm2+

1×54.6mm2+1×16mm2

3×70+

1×70mm2

Phase Conductor Cross Section (mm) 25 35 50 70 35 70 70
Number of Wires 7 7 7 12 7 12 12
Insulation Thickness (mm) 1.4 1.6 1.6 1.8 1.6 1.8 1.8
D.C.Resistance At 20 (Ohm/km) 1.2 0.868 0.641 0.443 0.868 0.443 0.443
Minium Rated Strength(daN) 300
Messenger Cross Section (mm) 54.6 54.6 54.6 54.6 54.6 54.6 70
Number of Wires 7 7 7 7 7 7 7
Insulation Thickness (mm) 1.6 1.6 1.6 1.6 1.6 1.6 1.5
D.C.Resistance A 20 ℃( Ohm/km) 0.63 0.63 0.63 0.63 0.63 0.63 0.5
Minium Rated Strength(daN) 1660 1660 1660 1660 1660 1660 2050
Public Lighting Cross Section (mm) 16 16
Number of Wires 7 7
Insulation Thickness (mm) 1.2 1.2
D.C.Resistance At 20 ℃(Ohm/km) 1.91 1.91
Minium Rated Strength(daN) 190 190
Conductor Diameter Phase Max 6.3 7.3 8.4 10.2 7.3 10.2 10.2
Min 5.8 6.8 7.9 9.7 6.8 9.7 9.7
Messenger Max 5.1 5.1
Min 4.6 4.6
Public Lighting Max 5.1 5.1
Min 4.6 4.6
Overall Diameter Phase Max 9.4 10.9 12 14.2 10.9 14.2 14.2
Min 8.6 10 11.1 13.3 10 13.3 13.3
Messenger Max 13 13 13 13 13 13 13.6
Min 12.3 12.3 12.3 12.3 12.3 12.3 12.9
Public Lighting Max 7.8 7.8
Min 7 7

STANDARDS

IEC 60228; IEC 60811-201; IEC 60811-401; IEC 60811-402; IEC 60811-501; IEC 60811-502; IEC 60811-507; IEC 60811-511; ASTM B 231; ICEA S-76-474;

NTP 370.254; NTP 370.258; NTP-IEC 60228; NFC 33-209

Marking:

(Nb. Cores x Section) + (Nb. conductors x public lighting section) + NA(Neutral messenger section) – Year – Sequential length.

About us

Zhenglan Cable Technology CO., Ltd.,formerly known as HENAN Zhengzhou Cable Co., Ltd., is one of the large scale backbone enterprises in China's wire and cable industry. The company's registered capital is about 4 million 6 thousand yuan and its headquarter is located in 49 floor of the South Tower of the Greenland Center of Zhengzhou high railway station (Petronas Twin Towers). The factory is located in the Zhengzhou cable science and Technology Industrial Park of the Wuzhi industrial area. It is a modern industrial park integrating advanced research and development technology and production technology.

We are China Stranded Aluminum Conductor XLPE ABC Aerial Bundle Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , , ,