Steel Reinforced Aluminium Conductor Cable For Electrical Power ACSR 192.5MCM ASTM 232
Steel Reinforced Aluminium Conductor Cable For Electrical Power ACSR 192.5MCM ASTM 232 image
Aluminium Conductor Steel Reinforced Cable For Electrical Power Transmission ACSR 192.5MCM BUNTING
APPLICATION
ACSR conductors are widely used for electrical power transmission over long distances, since they are ideal for long overhead lines spans. They are also used as a messenger for supporting overhead electrical cables.
STANDARD
Basic design to BS 215-2 / BS EN 50182 / IEC 61089 / ASTM B 232/B 232M / DIN 48204 / JIS C 3110 standards.
Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
CONSTRUCTION
ACSR conductors are formed by several wires of aluminium and galvanized steel, stranded in concentric layers. The wire or wires which form the core, are made of galvanized steel and the external layer or layers, are of aluminium. Galvanized steel core consist normally of 1, 7 or 19 wires. The diameters of steel and aluminium wires can be the same, or different.
By varying the relative proportions of aluminium and steel, the required characteristics for any particular application can be reached. A higher U. T. S. Can be obtained, by increasing steel content, and a higher current carrying capacity by increasing aluminium content.
ELECTRICAL PROPERTIES
density@20ºC | Aluminium: 2.703 kg/dm |
Galvanised Steel: 7.80 kg/dm | |
Temperature Coefficient@20°C | Aluminium: 0.00403 (°C) |
resistivity@20°C | Aluminium: Should not exceed 0.028264 |
linear Expansivity |
Aluminium: 23 x10 (°C) |
Galvanised Steel: 11.5 x10 (1/°C) |
Aluminium Conductor Steel Reinforced Cable SERVICE CONDITIONS
Ambient Temperature | -5°C – 50°C |
Wind Pressure | 80 – 130kg/m |
Seismic Acceleration | 0.12 – 0.05g |
Isokeraunic level | 10 – 18 |
relative Humidity | 5 – 100% |
TECHNICAL DATA
Numbers of Wires | Modules of Elasticity | Coeficient of linear Expansion | |||
AL | STEEL | Kg/mm2 | Lb/in2 | 1/Cº | 1/Fº |
6 | 1 | 81 | 11.5 x106 | 19.1 x10-6 | 10.6 x10-6 |
6 | 7 | 77 | 11.0 x106 | 19.8 x10-6 | 11.0 x10-6 |
12 | 7 | 107 | 15.2 x106 | 15.3 x10-6 | 8.5 x10-6 |
18 | 1 | 67 | 9.5 x106 | 21.2 x10-6 | 11.8 x10-6 |
24 | 7 | 74 | 10.5 x106 | 19.6 x10-6 | 10.9 x10-6 |
26 | 7 | 77 | 10.9 x106 | 18.9 x10-6 | 10.5 x10-6 |
28 | 7 | 79 | 11.2 x106 | 18.4 x10-6 | 10.2 x10-6 |
30 | 7 | 82 | 11.6 x106 | 17.8 x10-6 | 9.9 x10-6 |
30 | 19 | 80 | 11.4 x106 | 18.0 x10-6 | 10.0 x10-6 |
32 | 19 | 82 | 11.7 x106 | 17.5 x10-6 | 9.7 x10-6 |
54 | 7 | 70 | 9.9 x106 | 19.3 x10-6 | 10.7 x10-6 |
54 | 19 | 68 | 9.7 x106 | 19.4 x10-6 | 10.8 x10-6 |
CONSTRUCTION PARAMETERS
•ASTM B232
Code Name | Construction | Calculated Aluminum Area | Calculated Breaking Load | Calculated | Current Carrying Capacity | ||||
Aluminum | Steel | ||||||||
– | AWG/MCM | Nos./㎜ | ㎟ | ㎜ | ㎏/㎞ | kgf | Ϊ/㎞ | A | |
Turkey | 6 | 6/1.679 | 1/1.679 | 13.28 | 5.04 | 53.67 | 539.94 | 2.1595 | 89 |
Swan | 4 | 6/2.118 | 1/2.118 | 21.14 | 6.35 | 85.41 | 844.71 | 1.3571 | 120 |
Sparrow | 2 | 6/2.672 | 1/2.672 | 33.64 | 8.02 | 135.93 | 1,291.73 | 0.8527 | 161 |
Robin | 1 | 6/3.000 | 1/3.000 | 42.41 | 9 | 171.35 | 1,615.87 | 0.6764 | 186 |
Raven | 1/0 | 6/3.371 | 1/3.371 | 53.55 | 10.11 | 216.35 | 1,984.35 | 0.5357 | 216 |
Quail | 2/0 | 6/3.782 | 1/3.782 | 67.4 | 11.35 | 272.33 | 2,400.98 | 0.4256 | 250 |
Pigeon | 3/0 | 6/4.247 | 1/4.247 | 85 | 12.74 | 343.41 | 2,994.40 | 0.3375 | 290 |
Penguin | 4/0 | 6/4.770 | 1/4.770 | 107.22 | 14.31 | 433.19 | 3,777.31 | 0.2676 | 337 |
Waxwing | 266.8 | 18/3.091 | 1/3.091 | 135.07 | 15.46 | 430.78 | 3,113.00 | 0.2134 | 400 |
Partridge | 266.8 | 26/2.573 | 7/2.002 | 135.19 | 16.3 | 546.67 | 5,118.90 | 0.2143 | 406 |
Ostrich | 300 | 26/2.728 | 7/2.121 | 151.97 | 17.28 | 614.23 | 5,749.42 | 0.1906 | 437 |
Merlin | 336.4 | 18/3.472 | 1/3.472 | 170.42 | 17.36 | 543.52 | 3,927.72 | 0.1692 | 464 |
Linnet | 336.4 | 26/2.888 | 7/2.245 | 170.32 | 18.29 | 688.31 | 6,393.91 | 0.1701 | 470 |
Oriole | 336.4 | 30/2.690 | 7/2.690 | 170.5 | 18.83 | 784.58 | 7,876.39 | 0.1703 | 474 |
Chikadee | 397.5 | 18/3.774 | 1/3.774 | 201.36 | 18.87 | 642.18 | 4,506.82 | 0.1432 | 516 |
Brant | 397.5 | 24/3.269 | 7/2.179 | 201.43 | 19.61 | 761.98 | 6,630.92 | 0.1438 | 521 |
Ibis | 397.5 | 26/3.139 | 7/2.441 | 201.21 | 19.88 | 813.34 | 7,384.19 | 0.144 | 523 |
Lark | 397.5 | 30/2.924 | 7/2.924 | 201.45 | 20.47 | 927.02 | 9,249.01 | 0.1442 | 527 |
Pelican | 477 | 18/4.135 | 1/4.135 | 241.72 | 20.68 | 770.91 | 5,318.59 | 0.1193 | 580 |
Flicker | 477 | 24/3.581 | 7/2.388 | 241.72 | 21.49 | 914.59 | 7,799.74 | 0.1199 | 586 |
Hawk | 477 | 26/3.439 | 7/2.675 | 241.51 | 21.78 | 976.4 | 8,865.69 | 0.12 | 588 |
Hen | 477 | 30/3.203 | 7/3.203 | 241.73 | 22.42 | 1,112.37 | 10,785.80 | 0.1201 | 592 |
Osprey | 556.5 | 18/4.465 | 1/4.465 | 281.84 | 22.33 | 898.87 | 6,201.38 | 0.1023 | 640 |
Parakeet | 556.5 | 24/3.868 | 7/2.578 | 282.02 | 23.21 | 1,066.76 | 8,988.20 | 0.1027 | 646 |
Dove | 556.5 | 26/3.716 | 7/2.891 | 281.98 | 23.54 | 1,140.16 | 10,273.35 | 0.1027 | 649 |
Eagle | 556.5 | 30/3.459 | 7/3.459 | 281.91 | 24.21 | 1,297.28 | 12,578.81 | 0.103 | 654 |
Peacock | 605 | 24/4.034 | 7/2.690 | 306.74 | 24.21 | 1,160.60 | 9,781.27 | 0.0944 | 682 |
Squab | 605 | 26/3.874 | 7/3.012 | 306.47 | 24.53 | 1,238.68 | 11,141.36 | 0.0945 | 685 |
Teal | 605 | 30/3.607 | 19/2.164 | 306.55 | 25.25 | 1,398.33 | 13,589.86 | 0.0947 | 689 |
Kingbird | 636 | 18/4.775 | 1/4.775 | 322.34 | 23.88 | 1,028.02 | 7,092.38 | 0.0894 | 697 |
Rook | 636 | 24/4.135 | 7/2.756 | 322.29 | 24.81 | 1,219.12 | 10,273.07 | 0.0899 | 704 |
Grosbeak | 636 | 26/3.973 | 7/3.089 | 322.33 | 25.16 | 1,302.81 | 11,407.67 | 0.0899 | 707 |
Egret | 636 | 30/3.698 | 19/2.220 | 322.21 | 25.89 | 1,470.50 | 14,295.77 | 0.0901 | 712 |
Flamingo | 666.6 | 24/4.234 | 7/2.822 | 337.91 | 25.4 | 1,278.20 | 10,769.89 | 0.0857 | 726 |
Gannet | 666.6 | 26/4.067 | 7/3.162 | 337.76 | 25.75 | 1,365.16 | 11,953.50 | 0.0858 | 728 |
Product show
Why you choose us?
- OEM/ODM services provided;
- Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted;
- Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007;
- Registered capital of $30 million and factory covers an area of 60,000㎡;
- Advanced test equipment and procedures, 100% inspection before factory;
- Enough stocks and the higest efficient shipping time guarranteed;
- Professional pre-sales and after-sales services provided.
We are China Steel Reinforced Aluminium Conductor Cable For Electrical Power ACSR 192.5MCM ASTM 232 manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: ACSR Bare Aluminium Conductor Cable, ASTM 232 Bare Aluminium Conductor Cable, Bare Aluminum Conductor, Steel Reinforced Bare Aluminium Conductor Cable