Screend Power Medium Voltage Cable Fire resistant Polyvinyl Chloride Sheath
Screend Power Medium Voltage Cable Fire resistant Polyvinyl Chloride Sheath image
Screend Power Medium Voltage Cable Fire resistant Polyvinyl Chloride Sheath
MEDIUM VOLTAGE CABLE STANDARD
International: IEC60502-2
National: GB/T 12706.1-2008
Other standards: such as BS, DIN and ICEA, design & manufacture special power cable according to customer’s special request.
MEDIUM VOLTAGE CABLE CONSTRUCTION
Construction: Compacted stranded circular copper conductor, extruded semi-conducting compound as conductor screen, cross-linked polyethylene(XLPE) insulation, semi-conducting compound as insulation screen, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic polypropylene filler, wrapped with binder tape, PVC inner covering as armor bedding, double steel tape armored, PVC or PE outer sheath.
MEDIUM VOLTAGE CABLE APPLICATION
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, outdoors, in tunnel, in cable trench, or direct in ground, able to bear external mechanical force, but unable to bear large pulling force.
MEDIUM VOLTAGE CABLE CHARACTERISTICS
Max. permissible continuous operating temperature of conductor: 90 °C
The bending radius of cable is recommended as following:
MEDIUM VOLTAGE CABLE TYPES
Model |
Name |
Application |
Cable Cores |
Section area (mm) |
|
Copper Core |
Aluminum Core |
||||
YJV |
YJLV |
CU/AL Conductor, XLPE Insulated, PVC Sheathed Power Cable |
XLPE insulation PVC/PE sheathed power cables are used for laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces and pulling forces. Single core cable can't laying in magnetic ducts . |
1C |
25 | 400 |
YJY |
YJLY |
CU/AL Conductor, XLPE Insulated, PE Sheathed Power Cable |
|||
YJV22 |
YJLV22 |
CU/AL Conductor, XLPE Insulated,Steel-Tape Armored,PVC Sheathed Power Cable |
XLPE insulation PVC/PE sheathed steel-tape armored power cables can be buried directly .Able to bear external mechanical forces but large pulling forces. |
||
YJV23 |
YJLV23 |
CU/AL Conductor, XLPE Insulated,Steel-Tape Armored,PVC Sheathed Power Cable |
|||
YJV32 |
YJLV32 |
CU/AL Conductor, XLPE Insulated,Thin Steel-Wire Armored,PVC Sheathed Power Cable |
XLPE insulation armoured power cables can apply to shafts,water and soil. Able to bear moderate pulling forces. |
||
YJV33 |
YJLV33 |
CU/AL Conductor, XLPE Insulated,Thin Steel-Wire Armored,PE Sheathed Power Cable |
|||
YJV42 |
YJLV42 |
CU/AL Conductor, XLPE Insulated,Thick Steel-Wire Armored,PVC Sheathed Power Cable |
Steel-wire armored,PVC/PE Sheathed Power Cables are apply to shafts,water and soil.Able to bear large pulling forces. |
||
YJV43 |
YJLV43 |
CU/AL Conductor, XLPE Insulated,Thick Steel-Wire Armored,PE Sheathed Power Cable |
1 CORE 12/20KV POWER CABLE DATA
No. of cores and cross -sec. |
Operation |
Nominal |
Insulation |
Sheath |
Outer Ø |
weight |
Current ratings in air 30℃ |
Current ratings buried 20℃ |
maximum DC resistance at 20℃ |
---|---|---|---|---|---|---|---|---|---|
mm² |
kV |
kV |
mm |
mm |
mm |
kg / km |
A |
A |
Ω/km |
1 x 35 |
24 |
12/ 20 |
5.5 |
1.8 |
24.9 |
860 |
205 |
190 |
0.52 |
1 x 50 |
24 |
12/ 20 |
5.5 |
1.8 |
26.4 |
1138 |
245 |
225 |
0.39 |
1 x 70 |
24 |
12/ 20 |
5.5 |
1.9 |
28.1 |
1281 |
305 |
275 |
0.27 |
1 x 95 |
24 |
12/ 20 |
5.5 |
1.9 |
29.9 |
1570 |
370 |
330 |
0.19 |
1 x 120 |
24 |
12/ 20 |
5.5 |
2.0 |
31.3 |
1839 |
430 |
375 |
0.15 |
1 x 150 |
24 |
12/ 20 |
5.5 |
2.0 |
33.1 |
2174 |
490 |
425 |
0.12 |
1 x 185 |
24 |
12/ 20 |
5.5 |
2.1 |
34.7 |
2540 |
560 |
480 |
0.10 |
1 x 240 |
24 |
12/ 20 |
5.5 |
2.2 |
37.1 |
3120 |
665 |
555 |
0.08 |
1 x 300 |
24 |
12/ 20 |
5.5 |
2.2 |
39.5 |
3746 |
765 |
630 |
0.06 |
1 x 400 |
24 |
12/ 20 |
5.5 |
2.3 |
44.1 |
4863 |
890 |
725 |
0.05 |
1 x 500 |
24 |
12/ 20 |
5.5 |
2.4 |
47.6 |
5905 |
1030 |
825 |
0.04 |
1 x 630 |
24 |
12/ 20 |
5.5 |
2.5 |
51.3 |
7220 |
1190 |
940 |
0.03 |
3 CORE 12/20KV POWER CABLE DATA
No.cores x cross-sec. |
Operation |
Nominal |
Insulation |
Sheath |
Outer Ø |
weight |
Current ratings in air 30℃ |
Current ratings buried 20℃ |
maximum DC resistance at 20℃ |
---|---|---|---|---|---|---|---|---|---|
mm² |
kV |
kV |
mm |
mm |
mm |
kg / km |
A |
A |
Ω/km |
3 x 35 |
24 |
12/20 |
5.5 |
2.6 |
52.5 |
3023 |
155 |
185 |
0.52 |
3 x 50 |
24 |
12/20 |
5.5 |
2.7 |
55.5 |
3891 |
180 |
218 |
0.39 |
3 x 70 |
24 |
12/20 |
5.5 |
2.8 |
59.3 |
4396 |
223 |
267 |
0.27 |
3 x 95 |
24 |
12/20 |
5.5 |
3.0 |
63 |
5264 |
271 |
318 |
0.19 |
3 x 120 |
24 |
12/20 |
5.5 |
3.1 |
66.2 |
6190 |
312 |
363 |
0.15 |
3 x 150 |
24 |
12/20 |
5.5 |
3.2 |
69.8 |
7240 |
363 |
417 |
0.12 |
3 x 185 |
24 |
12/20 |
5.5 |
3.3 |
73.7 |
8499 |
404 |
460 |
0.1 |
3 x 240 |
24 |
12/20 |
5.5 |
3.5 |
78.6 |
10353 |
471 |
531 |
0.08 |
3 x 300 |
24 |
12/20 |
5.5 |
3.6 |
83.8 |
12328 |
536 |
596 |
0.06 |
3 x 400 |
24 |
12/20 |
5.5 |
3.8 |
93.6 |
15921 |
630 |
684 |
0.05
|
We are China Screend Power Medium Voltage Cable Fire resistant Polyvinyl Chloride Sheath manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: Medium Voltage Cable, medium voltage wire, xlpe medium voltage cables