RVV Fire Resistant Twin And Earth Cable , House Wire Cable have PVC insulated (300/500V)
RVV Fire Resistant Twin And Earth Cable , House Wire Cable have PVC insulated (300/500V) image
RVV Fire Resistant Twin And Earth Cable , House Wire Cable have PVC insulated (300/500V)
Twin And Earth Cable Application:
Mainly used in power lines, control lines and signal transmission lines for electrical appliances, instrumentation, electronic equipment and automation devices, specifically used in anti-theft alarm systems, building intercom systems, etc.
Twin And Earth Cable Construction
Conductor: flexible conductor class5 (GB/T 3956 class 5 or IEC60228.5)
Core number: 2core to 41core
Insulation: compound PVC
Outer sheath:compound PVC
Rated voltage
300/500V (GB/T5023.3-2008 or 60227 IEC52)
450/750V (GB/T5023.3-2008 or 60227 IEC53)
Service temperature: -30~ +70℃
Bending radius: 15D
Packaging: 100m/roll or as request
Remarks: Flame retardant, fire resistance (adopt mica tape), low smoking and Halogen free, or other property are available.
ZR cable (flame retardant cable) is the kind of cable with PVC insulation built mixed with fire prevention additive to make it have the capability of preventing or retarding flame spread during combustion.
There are 3 grades of fire prevention available which are
Grade A It is the highest level of flame retardancy. That is, the insulation material, filling rope, fastening (inner cushion) belt/layer and sheath material used in cables are all flame retardant materials.
Grade B Except the insulation material, all other materials are flame retardant.
Grade C Only the sheath material is flame retardant
NH cable (fire resistant cable) is the kind of cable built with a layer of mica tape. Even if the plastic skin is burnt out, refractory layer will help not cause short circuit. When wiring, cut off the refractory layer at the wire head.
LSZH,LSOH,LS0H,LSFH or OHLS cable(Low smoke zero halogen cable)is cable with insulation or outer sheath built using low smoke zero halogen free material to help reduce toxic and corrosive gases produced during combustion.
Termite-proof cable is the cable built with insulation or outer sheath mixed with a kind of materials to prevent termite biting the cable.
Twin And Earth Cable Data sheet
300/300V
Core number/sectional area(mm²) | Stranded Wire number/diameter(mm) | Max. Diameter(mm) |
Weight (kg/km) |
2×0.5 | 16/0.2 | 5.9 | 47.9 |
2×0.75 | 24/0.2 | 6.3 | 56.2 |
3×0.5 | 16/0.2 | 6.3 | 58.4 |
3×0.75 | 24/0.2 | 6.7 | 72.9 |
300/500V
Core number/sectional area (mm²) |
Insulation thickness(mm) | Outer sheath thickness(mm) | Outer diameter(mm) | 70℃minimum insulation resistance(mΩ/km) |
2×1.0 | 0.6 | 0.8 | 5.2×7.3 | 0.010 |
2×1.5 | 0.7 | 0.8 | 5.8×8.0 | 0.010 |
2×2.5 | 0.8 | 1.0 | 7.1×10.0 | 0.0090 |
2×4.0 | 0.8 | 1.0 | 7.9×11.6 | 0.0085 |
2×4.0 | 0.8 | 1.1 | 12.4 | 0.0070 |
2×6.0 | 0.8 | 1.1 | 8.8×13.4 | 0.0080 |
2×6.0 | 0.8 | 1.1 | 14.5 | 0.0080 |
2×10.0 | 0.8 | 1.2 | 14.3 | 0.056 |
3×4.0 | 0.8 | 1.2 | 13.5 | 0.0070 |
3×6.0 | 0.8 | 1.2 | 14.0 | 0.0070 |
4×4.0 | 0.8 | 1.2 | 14.6 | 0.0070 |
4×6.0 | 0.8 | 1.2 | 16.0 | 0.0060 |
4×10.0 | 1.0 | 1.4 | 19.0 | 0.0056 |
5×4.0 | 0.8 | 1.4 | 16.5 | 0.0070 |
5×6.0 | 1.0 | 1.4 | 17.5 | 0.0060 |
5×10.0 | 1.2 | 1.6 | 22.0 | 0.0056 |
6×0.75 | 0.4 | 0.8 | 9.6 | 0.011 |
6×1.0 | 0.6 | 1.0 | 11.0 | 0.010 |
6×1.5 | 0.7 | 1.1 | 13..3 | 0.010 |
6×2.5 | 0.8 | 1.2 | 15.8 | 0.0090 |
7×0.75 | 0.4 | 0.8 | 9.6 | 0.011 |
7×1.0 | 0.6 | 1.1 | 11.0 | 0.010 |
7×1.5 | 0.7 | 1.1 | 13.3 | 0.010 |
7×2.5 | 0.8 | 1.2 | 16.0 | 0.0090 |
8×0.75 | 0.4 | 1.0 | 10.6 | 0.011 |
8×1.0 | 0.6 | 1.2 | 13.2 | 0.010 |
8×1.5 | 0.7 | 1.2 | 14.2 | 0.010 |
10×0.5 | 0.4 | 1.0 | 10.5 | 0.012 |
10×0.75 | 0.4 | 1.0 | 13.2 | 0.011 |
10×1.0 | 0.6 | 1.2 | 14.5 | 0.010 |
10×1.5 | 0.7 | 1.4 | 16.7 | 0.010 |
10×2.5 | 0.8 | 1.5 | 20.0 | 0.009 |
12×0.5 | 0.4 | 1.0 | 11.0 | 0.012 |
12×0.75 | 0.4 | 1.2 | 13.2 | 0.011 |
15×0.75 | 0.4 | 1.2 | 14.0 | 0.011 |
15×1.0 | 0.6 | 1.2 | 15.5 | 0.010 |
16×0.75 | 0.4 | 1.2 | 14.0 | 0.010 |
16×1.0 | 0.6 | 1.2 | 15.5 | 0.010 |
19×0.75 | 0.4 | 1.2 | 15.0 | 0.011 |
19×1.0 | 0.6 | 1.2 | 17.8 | 0.010 |
20×0.5 | 0.4 | 1.2 | 14.0 | 0.012 |
20×0.75 | 0.4 | 1.2 | 15.5 | 0.011 |
20×1.0 | 0.6 | 1.2 | 18.3 | 0.010 |
24×0.75 | 0.4 | 1.2 | 17.0 | 0.011 |
24×1.0 | 0.6 | 1.2 | 20.5 | 0.010 |
25×0.75 | 0.4 | 1.2 | 17.1 | 0.011 |
25×1.0 | 0.6 | 1.2 | 20.8 | 0.010 |
30×0.75 | 0.4 | 1.4 | 19.5 | 0.011 |
30×1.0 | 0.6 | 1.4 | 22.6 | 0.010 |
37×0.75 | 0.4 | 1.4 | 21.6 | 0.011 |
37×1.0 | 0.6 | 1.4 | 23.0 | 0.010 |
40×0.75 | 0.4 | 1.4 | 21.8 | 0.011 |
40×01.0 | 0.6 | 1.4 | 25.5 | 0.010 |
41×0.75 | 0.4 | 1.4 | 22.5 | 0.011 |
41×0.75 | 0.6 | 1.4 | 27.0 | 0.010 |
Why Choose Zhenglan Cable:
- OEM/ODM services provided;
- Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted;
- Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007;
- Registered capital of $30 million and factory covers an area of 60,000㎡;
- Advanced test equipment and procedures, 100% inspection before factory;
- Enough stocks and the higest efficient shipping time guarranteed;
- Professional pre-sales and after-sales services provided.
We are China RVV Fire Resistant Twin And Earth Cable , House Wire Cable have PVC insulated (300/500V) manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: multi strand electrical wire, Twin And Earth Cable, two core and earth cable