PVC Insulated Twin And Earth Cable /BVV Cable 300/500V For Home / Building/Core Number: 2 Core, 3 Core, 4 Core Or 5 Core
PVC Insulated Twin And Earth Cable /BVV Cable 300/500V For Home / Building/Core Number: 2 Core, 3 Core, 4 Core Or 5 Core image
PVC Insulated Twin And Earth Cable /BVV Cable 300/500V For Home / Building/Core Number: 2 Core, 3 Core, 4 Core Or 5 Core
Insulated Twin And Earth Cable Application:
The wiring cable type PP is intended for dry and wet conditions, for laying either on the surface or under plaster without any special mechanic protection.
Construction:
Core number: 2core, 3 core, 4 core or 5 core
Conductor: confirms to specification GB/T3956-1997 or IEC 60228
Solid conductor class1
Stranded conductor class2
Insulation: PVC
Outer sheath: PVC
Electrical characteristics:
Rated voltage: 300/500V
Test voltage: 2000 V
Conductor working temeprature max. +70°C (under normal conditions)
Minimum bending radius:
For cable with diameter below 25mm, allowed bending radius should not be less than 4D;For cable with diameter above and including 25mm, allowed bending radius should not be less than 6D;
Operating temperatures: Mounting -5° – +40°C Operating -30° – +70°C
Core marking:
2-cores: Brown, Blue
3-cores: Brown, Yellow-green, Blue
4-cores: Brwon, Black, Grey, Yellow-green
5-cores: Brown, Black, Grey, Yellow-green, Blue
Standard: 60227 IEC10 or GB/T5023.4-2008
Packing: 100m per roll(per coil or plastic reel, as your request)
Remarks:
Flame retardant, fire resistance(adopt mica tape), low smoking and Halogen free, or other property are available.
ZR cable(flame retardant cable) is the kind of cable with PVC insulation built mixed with fire prevention additive to make it have the capability of preventing or retarding flame spread during combustion.
There are 3 grades of fire prevention available which are
Grade A It is the highest level of flame retardancy. That is, the insulation material, filling rope, fastening (inner cushion) belt/layer and sheath material used in cables are all flame retardant materials.
Grade B Except the insulation material, all other materials are flame retardant.
Grade C Only the sheath material is flame retardant
NH cable(fire resistant cable) is the kind of cable built with a layer of mica tape. Even if the plastic skin is burnt out, refractory layer will help not cause short circuit. When wiring, cut off the refractory layer at the wire head.
LSZH,LSOH,LS0H,LSFH or OHLS cable(Low smoke zero halogen cable)is cable with insulation or outer sheath built using low smoke zero halogen free material to help reduce toxic and corrosive gases produced during combustion.
Termite-proof cable is the cable built with insulation or outer sheath mixed with a kind of materials to prevent termite biting the cable.
Insulated Twin And Earth Cable Data sheet
Construction of Cable | Construction of Conductor | Insulation Thickness | Sheath Thickness | Overall Dia | Min.Insulation Resistance at 70℃ | Total Weght |
mm² | nxmm | mm | mm | mm | MΩkm | Kg/kmΩ/km |
2×1.5 | 1×1.36 | 0.6 | 1.4 | 8.8 | 0.010 | 117 |
2×2.5 | 1×1.78 | 0.7 | 1.4 | 10.0 | 0.009 | 160 |
2×4 | 1×2.26 | 0.8 | 1.4 | 11.4 | 0.009 | 227 |
2×6 | 1×2.7 | 0.8 | 1.4 | 12.2 | 0.007 | 274 |
2×10 | 1×3.5 | 1.0 | 1.6 | 15.6 | 0.007 | 450 |
2×16 | 7×1.75 | 1.0 | 1.6 | 18.4 | 0.005 | 680 |
2×25 | 7×2.20 | 1.2 | 1.6 | 21.6 | 0.005 | 1010 |
2×35 | 7×2.60 | 1.2 | 1.8 | 25.0 | 0.004 | 1388 |
3×1.5 | 1×1.38 | 0.6 | 1.4 | 9.1 | 0.010 | 133 |
3×2.5 | 1×1.78 | 0.7 | 1.4 | 10.2 | 0.009 | 189 |
3×4 | 1×2.26 | 0.8 | 1.4 | 11.8 | 0.009 | 270 |
3×6 | 1×2.70 | 0.8 | 1.6 | 13.5 | 0.007 | 258 |
3×10 | 1×3.5 | 1.0 | 1.6 | 16.5 | 0.007 | 568 |
3×16 | 7×1.75 | 1.0 | 1.6 | 19.5 | 0.005 | 837 |
3×25 | 7×2.20 | 1.2 | 1.8 | 24.0 | 0.005 | 1280 |
3×35 | 7×2.60 | 1.2 | 1.8 | 26.7 | 0.004 | 1670 |
4×1.5 | 1×1.38 | 0.6 | 1.4 | 9.8 | 0.010 | 159 |
4×2.5 | 1×1.78 | 0.7 | 1.4 | 11.4 | 0.009 | 233 |
4×4 | 1×2.26 | 0.8 | 1.6 | 13.5 | 0.009 | 338 |
4×6 | 1×2.70 | 0.8 | 1.6 | 14.4 | 0.007 | 423 |
4×10 | 1×3.5 | 1.0 | 1.6 | 17.3 | 0.007 | 646 |
4×16 | 7×1.75 | 1.0 | 1.6 | 21.8 | 0.005 | 1030 |
4×25 | 7×2.20 | 1.2 | 1.8 | 26.0 | 0.005 | 1590 |
4×35 | 7×2.60 | 1.2 | 1.8 | 29.3 | 0.004 | 2080 |
5×1.5 | 1×1.38 | 0.6 | 1.4 | 10.7 | 0.010 | 186 |
5×2.5 | 1×1.78 | 0.7 | 1.4 | 12.2 | 0.009 | 270 |
5×4 | 1×2.26 | 0.8 | 1.6 | 14.6 | 0.009 | 409 |
5×6 | 1×2.70 | 0.8 | 1.6 | 15.7 | 0.007 | 509 |
5×10 | 1×3.5 | 1.0 | 1.6 | 19.0 | 0.007 | 815 |
5×16 | 7×1.75 | 1.0 | 1.8 | 23.8 | 0.005 | 1285 |
5×25 | 7×2.20 | 1.2 | 1.8 | 28.7 | 0.005 | 1950 |
5×35 | 7×2.60 | 1.2 | 1.8 | 32.1 | 0.004 | 2610 |
Products show
Why Choose Zhenglan Cable:
- OEM/ODM services provided;
- Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted;
- Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007;
- Registered capital of $30 million and factory covers an area of 60,000㎡;
- Advanced test equipment and procedures, 100% inspection before factory;
- Enough stocks and the higest efficient shipping time guarranteed;
- Professional pre-sales and after-sales services provided.
We are China PVC Insulated Twin And Earth Cable /BVV Cable 300/500V For Home / Building/Core Number: 2 Core, 3 Core, 4 Core Or 5 Core manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: stranded copper wire, Twin And Earth Cable, two core and earth cable