PE / XLPE Insulation Muti Core Aluminum Conductor Drop Wire 0.6KV / 1KV

 China PE / XLPE Insulation Muti Core Aluminum Conductor Drop Wire 0.6KV / 1KV supplier

PE / XLPE Insulation Muti Core Aluminum Conductor Drop Wire 0.6KV / 1KV image

Get a Quote Email to us

Brand Name :
SHANCABLE

Model Number :
ABC-AL/PVC/1KV-3 CORES+1 BARE

Certification :
IEC 60502

Place of Origin :
Shanghai, China

MOQ :
0.5km

Price :
0.10-25.99USD/m

Payment Terms :
L/C, D/P, D/A, T/T, Western Union, MoneyGram

Supply Ability :
1000km per month

Delivery Time :
10 days or more

Packaging Details :
Wooden Drum or Steel Drum

Phase Conductor :
Aluminium

Neutral Conductor :
Aluminium Alloy

Rated Voltage :
0.6/1KV

Insulation :
XLPE

Application :
Voltage of 600 volts

Marking :
Color Line

Muti Core Aluminum Conductor Drop Wire Used at Voltage of 600 Volts

Applications

To supply power from the utilitys lines to the consumers weatherhead.For service at 600 volts or less(phase to phase) at a conductor temperature of 75oC maximum for polyethylene insulation or 90 oC maximum for crosslinked insulation.

Construcrtion

1.stranded aluminium conductor
2.PE or XLPE insulation
3.ACSR, AAAC,Galvanised steel wire Messenger wire
3 power cores consisting of standard aluminium conductors, insulated with XLPE insulation
+ One sheath lighting aluminium conductor with XLPE insulation(optional)
+ One messenger Al-alloy conductor (bare or covered)
The purpose of messenger wire is
A) It acts as load bearing wire.
B) It acts as earth or neutral conductor

Technical Data:
Maksimum operating temperature 90 degree
Maximum short-circuit temperature 250 degree.Service drop( ABC cables) are especially used at areas where the cost of underground networks is expensive and also for electrification of rural areas like village.

TECHNICAL PARAMETERS:

Code Name Phase Conductor Bare Neutral Approx.Weight
Size Stranding Insulation Thickness Size Stranding XLPE PE
AWG mil AWG lbs/1000ft
AAC Neutral Messenger
Pekingese 6 Solid 45 6 7/w 63.5 61.7
Collie 6 7/w 45 6 7/w 66.8 63.1
Dachshund 4 Solid 45 4 7/w 95.5 93.4
Spaniel 4 7/w 45 4 7/w 100.5 95.4
Doberman 2 7/w 45 2 7/w 152.7 145.7
Malemute 1/0 19/w 60 1/0 7/w 242.6 234.2
6201 Alloy Neutral Messenger
Chihuahua 6 Solid 45 6 7/w 67.6 65.8
Vizsla 6 7/w 45 6 7/w 70.9 67.2
Harrier 4 Solid 45 4 7/w 102.0 99.9
Code Name Phase Conductor Bare Neutral Approx.Weight
Size Stranding Insulation Thickness Size Stranding XLPE PE
AWG mil AWG lbs/1000ft
ACSR Neutral Messenger
Setter 6 Solid 45 6 6/1 75.0 73.2
Shepherd 6 7/w 45 6 6/1 78.3 74.6
Eskimo 4 Solid 45 4 6/1 113.7 111.6
Terrier 4 7/w 45 4 6/1 118.7 113.6
Chow 2 7/w 45 2 6/1 181.7 174.7
Bull 1/0 19/w 60 1/0 6/1 288.7 280.3
6201 Alloy Neutral Messenger
Whippet 4 7/w 45 4 7/w 107.0 101.9
Schnauzer 2 7/w 45 2 7/w 163.3 156.2
Heeler 1/0 19/w 60 1/0 7/w 259.2 250.8

Note:
(1)Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.
(2)Conductor temperature of 90°C for XLPE, 75°C for PE; ambient temperatures of 40°C; emissivity 0.9; 2ft./sec/wind in sun.

Classification

1. Duplex Service Drop

Primary used for 120 volt overhead service application such as street lighting, outdoor lighting, and temporay service for construction. To be used at voltages of 600 volts phase to phase or less and at conductor temperature not to exceed 75degee for polyethylene insulated conductor or 90 degree for crosslinked polyethylene (XLPE)insulated conductors.

2.Triplex Service Drop

Used to supply power, usually from a pole-mounted transformer to the user's service head where the connections to the service entrance cable is made. To be used at voltage of 600 volts phase to phase or less and at conductor temperature not to exceed 75degee for polyethylene insulated conductor or 90 degree for crosslinked polyethylene (XLPE)insulated conductors.

3. Quadruplex Service Drop

Used to supply 3 phase power, usually from a pole-mounted transformer to the user's service head where the connections to the service entrance cable is made. To be used at voltage of 600 volts phase to phase or less and at conductor temperature not to exceed 75degee for polyethylene insulated conductor or 90 degree for crosslinked polyethylene (XLPE)insulated conductors.

Package:In coils, wooden drums, steel drums or steel-wooden drums.





































We are China PE / XLPE Insulation Muti Core Aluminum Conductor Drop Wire 0.6KV / 1KV manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION