Wooden Drum or Steel Drum
Phase Conductor :
Aluminium
Neutral Conductor :
Aluminum Alloy
Street Lighting :
Aluminium
Insulation :
PE
Rated Voltage :
0.6/1KV
Application :
Overhead Power Line
No. of Cores :
5
PE Insulation Five Core Aerial Drop Cable STANDARD NF C 33-209 NFA 2X
Construction
- Conductor:
a)Phase – The phase conductor shall be of H68 Condition aluminium conductor and compacted circular stranded.
b)Neutral or messenger – The Neutral or messenger conductor shall be of aluminium alloy conductor and compacted circular stranded c)Street Lighting- The street lighting conductors shall be of H68 condition aluminium conductor and compacted circular stranded..
- Insulation:
The phase, neutral conductors shall be extruded with polyethylene(PE) as insulation.
Schedule of technical particulars
Phase conductor | |||||||||
Nominal cross-sectional area | mm² | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
Minimum number of wires | 6 | 6 | 6 | 12 | 15 | 15 | 30 | 30 | |
Nominal insulation thickness | mm | 1.2 | 1.2 | 1.4 | 1.4 | 1.6 | 1.6 | 1.8 | 2.0 |
Diameter of insulated core | mm | 8.5 | 9.5 | 11.2 | 13.0 | 15.1 | 16.6 | 18.4 | 20.6 |
Max. DC resistance at 20℃ | ohm/km | 1.20 | 0.868 | 0.641 | 0.443 | 0.320 | 0.253 | 0.206 | 0.164 |
Current rating at still wind, ambient | A | 84 | 104 | 129 | 167 | 209 | 246 | 283 | 332 |
temperature=30℃ | |||||||||
Conductor temperature=75℃ | |||||||||
Messenger conductor | |||||||||
Nominal cross-sectional area | mm² | 25 | 25 | 35 | 50 | 70 | 70 | 95 | 120 |
Minimum number of wires | 6 | 6 | 6 | 6 | 12 | 12 | 15 | 15 | |
Nominal insulation thickness | mm | 1.2 | 1.2 | 1.2 | 1.4 | 1.4 | 1.4 | 1.6 | 1.6 |
Diameter of insulated core | mm | 8.5 | 8.5 | 9.5 | 11.2 | 13.1 | 13.1 | 15.1 | 16.6 |
Max. DC resistance at 20℃ | ohm/km | 1.312 | 1.312 | 0.943 | 0.693 | 0.469 | 0.469 | 0.349 | 0.273 |
Calculated breaking load | kN | 6.4 | 6.4 | 8.9 | 12.1 | 18.0 | 18.0 | 24.2 | 30.8 |
Street lighting conductor | |||||||||
Nominal cross-sectional area | mm² | 25 | 25 | 35 | 50 | 70 | 70 | 95 | 120 |
Minimum number of wires | 6 | 6 | 6 | 6 | 12 | 12 | 15 | 15 | |
Nominal insulation thickness | mm | 1.2 | 1.2 | 1.2 | 1.4 | 1.4 | 1.4 | 1.6 | 1.6 |
Diameter of insulated core | mm | 8.5 | 8.5 | 9.5 | 11.2 | 13.1 | 13.1 | 15.1 | 16.6 |
Max. DC resistance at 20℃ | ohm/km | 1.312 | 1.312 | 0.943 | 0.693 | 0.469 | 0.469 | 0.349 | 0.273 |
Completed cable | |||||||||
Approx. overall diameter | mm | 23.2 | 25.6 | 30.0 | 34.9 | 40.6 | 44.1 | 49.2 | 54.9 |
Approx. weight of cable | kg/km | 470 | 560 | 740 | 980 | 1330 | 1580 | 1940 | 2410 |
Packing length | m/drum | 1000 | 1000 | 1000 | 1000 | 500 | 500 | 500 | 500 |
STANDARD NF C 33-209
NFA 2X
Phases | Neutral/Messenger | ||||||||
Distribution Lines | Pub. Lighting | ||||||||
Cable Type | Number of | Number of | Avarage | Resistance | Conductance | Number of | Avarage | Rated | Resistance |
core | wire | diameter | at 20℃ | at 30℃ | core | diameter | Strength | at 20℃ | |
mm² | mm² | PCS | mm | ohm/km | A | mm² | mm | kN | ohm/km |
2×16 | 2×16 | 7 | 4.6 | 1.91 | 93 | – | – | – | – |
2×35 | 2×35 | 7 | 5.9 | 1.20 | 122 | – | – | – | – |
2×35 | 2×35 | 7 | 6.9 | 0.868 | 129 | – | – | – | – |
2×50 | 2×50 | 7 | 8.1 | 0.641 | 158 | – | – | – | – |
4×16 | 4×16 | 7 | 4.6 | 1.91 | 83 | – | – | – | – |
4×25 | 4×25 | 7 | 5.9 | 1.20 | 111 | – | – | – | – |
4×35 | 4×35 | 7 | 6.9 | 0.868 | 131 | – | – | – | – |
3×25+54.6 | 3×25 | 7 | 5.9 | 1.20 | 112 | – | 9.6 | 16.0 | 0.63 |
3×25+1×16+54.6 | 3×25 | 7 | 5.9 | 1.20 | 112 | 1×16 | 9.6 | 16.0 | 0.63 |
3×25+2×16+54.6 | 3×25 | 7 | 5.9 | 1.20 | 112 | 2×16 | 9.6 | 16.0 | 0.63 |
3×35+54.6 | 3×35 | 7 | 6.9 | 0.868 | 138 | – | 9.6 | 16.0 | 0.63 |
3×35+1×16+54.6 | 3×35 | 7 | 6.9 | 0.868 | 138 | 1×16 | 9.6 | 16.0 | 0.63 |
3×35+2×16+54.6 | 3×35 | 7 | 6.9 | 0.868 | 138 | 2×16 | 9.6 | 16.0 | 0.63 |
3×50+54.6 | 3×50 | 7 | 8.1 | 0.641 | 168 | – | 9.6 | 16.0 | 0.63 |
3×50+1×16+54.6 | 3×50 | 7 | 8.1 | 0.641 | 168 | 1×16 | 9.6 | 16.0 | 0.63 |
3×50+2×16+54.6 | 3×50 | 7 | 8.1 | 0.641 | 168 | 2×16 | 9.6 | 16.0 | 0.63 |
3×70+54.6 | 3×70 | 12 | 9.7 | 0.443 | 213 | – | 9.6 | 16.0 | 0.63 |
3×70+1×16+54.6 | 3×70 | 12 | 9.7 | 0.443 | 213 | 1×16 | 9.6 | 16.0 | 0.63 |
3×70+2×16+54.6 | 3×70 | 12 | 9.7 | 0.443 | 213 | 2×16 | 9.6 | 16.0 | 0.63 |
3×70+1×25+54.6 | 3×70 | 12 | 9.7 | 0.443 | 213 | 1×25 | 9.6 | 16.0 | 0.63 |
3×70+2×25+54.6 | 3×70 | 12 | 9.7 | 0.443 | 213 | 2×25 | 9.6 | 16.0 | 0.50 |
3×70+70 | 3×70 | 12 | 9.7 | 0.443 | 213 | – | 10.2 | 20.6 | 0.50 |
3×70+1×16+70 | 3×70 | 12 | 9.7 | 0.443 | 213 | 1×16 | 10.2 | 20.6 | 0.50 |
3×70+2×16+70 | 3×70 | 12 | 9.7 | 0.443 | 213 | 2×16 | 10.2 | 20.6 | 0.50 |
3×95+70 | 3×95 | 12 | 11.5 | 0.320 | 258 | – | 10.2 | 20.6 | 0.50 |
3×95+1×16+70 | 3×95 | 12 | 11.5 | 0.320 | 258 | 1×16 | 10.2 | 20.6 | 0.50 |
3×95+2×16+70 | 3×95 | 12 | 11.5 | 0.320 | 258 | 2×16 | 10.2 | 20.6 | 0.50 |
3×120+70 | 3×120 | 12 | 12.8 | 0.253 | 300 | – | 10.2 | 20.6 | 0.50 |
3×120+1×16+70 | 3×120 | 19 | 12.8 | 0.253 | 300 | 1×16 | 10.2 | 20.6 | 0.50 |
3×120+2×16+70 | 3×120 | 19 | 12.8 | 0.253 | 300 | 2×16 | 10.2 | 20.6 | 0.50 |
3×150+70 | 3×150 | 19 | 14.5 | 0.206 | 344 | – | 10.2 | 20.6 | 0.50 |
3×150+1×16+70 | 3×150 | 19 | 14.5 | 0.206 | 344 | 1×16 | 10.2 | 20.6 | 0.50 |
3×150+2×16+70 | 3×150 | 19 | 14.5 | 0.206 | 344 | 2×16 | 10.2 | 20.6 | 0.50 |
3×120+95 | 3×120 | 19 | 12.8 | 0.253 | 300 | – | 12.9 | 27.9 | 0.343 |
3×120+1×16+95 | 3×120 | 19 | 12.8 | 0.253 | 300 | 1×16 | 12.9 | 27.9 | 0.343 |
3×120+2×16+95 | 3×120 | 19 | 12.8 | 0.253 | 300 | 2×16 | 12.9 | 27.9 | 0.343 |
3×150+95 | 3×150 | 19 | 14.5 | 0.206 | 344 | – | 12.9 | 27.9 | 0.343 |
3×150+1×16+95 | 3×150 | 19 | 14.5 | 0.206 | 344 | 1×16 | 12.9 | 27.9 | 0.343 |
3×150+2×16+95 | 3×150 | 19 | 14.5 | 0.206 | 344 | 2×16 | 12.9 | 27.9 | 0.343 |
ADVANTAGE
CERTIFICATION
FACTORY SHOW
INSPECTION PROCESS
PACKING AND SHIPPING
We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.
We are China PE Insulation Five Core Aerial Drop Cable STANDARD NF C 33-209 NFA 2X manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: aerial bunched cables, Aerial Bundled Cable, aerial electrical cable