Overhead Bare Conductor Wire(Nominal Area:10/63/200/1500/1250/1000/315mm2), AAC Conductor (AAC,AAAC,ACSR)
Overhead Bare Conductor Wire(Nominal Area:10/63/200/1500/1250/1000/315mm2), AAC Conductor (AAC,AAAC,ACSR) image
Brand Name :
Zhenglan Cable
Model Number :
Nominal Area:315mm2 AAC Overhead Bare Conductor Wire
Certification :
3C; ISO 9001:2015, ISO 14001:2005, OHSAS 18001:2007
Place of Origin :
Henan, China
MOQ :
300 meters
Payment Terms :
L/C, T/T, Western Union
Delivery Time :
15 days
Packaging Details :
Wooden drum, wood and steel drum,as customer’s request
Material :
AL
Out Sheath Color :
No
Core :
Normal or Customized
Cable Mark :
Ink printing or Embossing Content Customized
Cable Drum Length :
Normal or Customized
characted :
Bare Conductor
Armoured :
No
Nominal Area :
10~1500
Overhead Bare Conductor Wire(Nominal Area:315mm2), AAC Conductor according to IEC 61089
Bare Conductor Wire APPLICATION
AAC conductor is also known as aluminium stranded conductor. It is manufactured from electrolytically refined aluminium, with a minimum purity of 99.7%.
Bare Conductor Wire STANDARD
Basic design to BS 215-1 / BS EN 50182 / IEC 61089 / ASTM B 231/B 231M / DIN 48201-5 standards.
Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
Bare Conductor Wire CONSTRUCTION
Concentric lay stranded Aluminium Conductor (AAC) is made up of one or more strands of hard drawn 1350 aluminum alloy. These conductors are used in low, medium and high voltage overhead lines. AAC has seen extensive use in urban areas where spans are usually short but high conductivity us required. The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas. Because of its relatively poor strength to weight ratio, AAC had limited use in transmission lines and rural distribution because of long spans utilized. All aluminium conductors are made up of one or more strands of aluminium wire dep.
Bare Conductor Wire ELECTRICAL PROPERTIES
density@20ºC | 2.703 kg/dm |
Temperature Coefficient@20°C | 0.00403 (°C) |
resistivity@20°C | 0.028264 |
linear Expansivity | 23 x10 (°C) |
Ambient Temperature | -5°C – 50°C |
Wind Pressure | 80 – 130kg/m |
Seismic Acceleration | 0.12 – 0.05g |
Isokeraunic level | 10 – 18 |
relative Humidity | 5 – 100% |
Bare Conductor Wire TECHNICAL DATA
Numbers of Wires | Final modules of Elasticity | Coeficient of linear Expansion | ||
AL | Kg/mm2 | Lb/in2 | 1/Cº | 1/Fº |
7 | 6000 | 8.5 x106 | 23.0 x10-6 | 112.8 x10-6 |
19 | 5700 | 8.1 x106 | 23.0 x10-6 | 112.8 x10-6 |
37 | 5700 | 8.1 x106 | 23.0 x10-6 | 112.8 x10-6 |
61 | 5500 | 7.8 x106 | 23.0 x10-6 | 112.8 x10-6 |
91 | 5500 | 7.8 x106 | 23.0 x10-6 | 112.8 x10-6 |
CONSTRUCTION PARAMETERS
• IEC 60189
Code | Nominal Area | Stranding | Overall Diameter | Weight | Rated Strength | Electrical Resistance | Current Rating* |
10 | 10 | 7/1.35 | 4.05 | 27.4 | 1.95 | 2.8633 | 62 |
16 | 16 | 7/1.71 | 5.13 | 43.8 | 3.04 | 1.7896 | 84 |
25 | 25 | 7/2.13 | 6.39 | 68.4 | 4.5 | 1.1453 | 110 |
40 | 40 | 7/2.70 | 8.1 | 109.4 | 6.8 | 0.7158 | 147 |
63 | 63 | 7/3.39 | 10.17 | 172.3 | 10.39 | 0.4545 | 195 |
100 | 100 | 19/2.59 | 12.95 | 274.8 | 17 | 0.2877 | 259 |
125 | 125 | 19/2.89 | 14.45 | 343.6 | 21.25 | 0.2302 | 297 |
160 | 160 | 19/3.27 | 16.35 | 439.8 | 26.4 | 0.1798 | 345 |
200 | 200 | 19/3.66 | 18.3 | 549.7 | 32 | 0.1439 | 396 |
250 | 250 | 19/4.09 | 20.45 | 687.1 | 40 | 0.1151 | 454 |
315 | 315 | 37/3.29 | 23.03 | 867.9 | 51.97 | 0.0916 | 522 |
400 | 400 | 37/3.71 | 25.97 | 1102 | 64 | 0.0721 | 603 |
450 | 450 | 37/3.94 | 27.58 | 1239.8 | 72 | 0.0641 | 647 |
500 | 500 | 37/4.15 | 29.05 | 1377.6 | 80 | 0.0577 | 688 |
560 | 560 | 37/4.39 | 30.73 | 1542.9 | 89.6 | 0.0515 | 736 |
630 | 630 | 61/3.63 | 32.67 | 1738.3 | 100.8 | 0.0458 | 789 |
710 | 710 | 61/3.85 | 34.65 | 1959.1 | 113.6 | 0.0407 | 845 |
800 | 800 | 61/4.09 | 36.81 | 2207.4 | 128 | 0.0361 | 905 |
900 | 900 | 61/4.33 | 38.97 | 2483.3 | 144 | 0.0321 | 967 |
1000 | 1000 | 61/4.57 | 41.13 | 2759.2 | 160 | 0.0289 | 1026 |
1120* | 1120 | 91/3.96 | 43.56 | 3093.5 | 179.2 | 0.0258 | 1091 |
1250* | 1250 | 91/4.18 | 45.98 | 3452.6 | 200 | 0.0231 | 1157 |
1400* | 1400 | 91/4.43 | 48.73 | 3866.9 | 224 | 0.0207 | 1226 |
1500* | 1500 | 91/4.58 | 50.38 | 4143.1 | 240 | 0.0193 | 1270 |
Why you choose us?
- OEM/ODM services provided;
- Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted;
- Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007;
- Registered capital of $30 million and factory covers an area of 60,000㎡;
- Advanced test equipment and procedures, 100% inspection before factory;
- Enough stocks and the higest efficient shipping time guarranteed;
- Professional pre-sales and after-sales services provided.
We are China Overhead Bare Conductor Wire(Nominal Area:10/63/200/1500/1250/1000/315mm2), AAC Conductor (AAC,AAAC,ACSR) manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: Bare Aluminum Conductor, bare aluminum wire, bare electrical wire