Multi-core flexible ROUND 07RN8-F 450/750 V Rubber PUMP CABLE 4 x10+2×1.5mm2

 China Multi-core flexible ROUND 07RN8-F 450/750 V Rubber PUMP CABLE 4 x10+2×1.5mm2 supplier

Multi-core flexible ROUND 07RN8-F 450/750 V Rubber PUMP CABLE 4 x10+2×1.5mm2 image

Get a Quote Email to us

Brand Name :
Yifang

Model Number :
SUBMERSIBLE PUMP POWER CABLE

Certification :
CE, ISO

Place of Origin :
China

MOQ :
1000 meter

Price :
USD 1~10 per meter

Packaging Details :
Treated Wooden Drum

Standard :
EN 50525-2-21, IEC 60 245

Working Temperature :
-40° C to 90° C

Sheath Color :
Blue

Structure :
CU/EPR/EPR/CPE

Aplication :
Submersible pump

Excellent flexibility :
Yes

Multi-core flexible ROUND 07RN8-F 450/750 V Rubber PUMP CABLE

Application

 Designed for use in deep water up to 100 m.

 The cables can be used in industrial water, ground water and sea water.

 Heavy duty flexible cables are suited for use under medium mechanical stress especially for the connection of submersible motor pumps in site drainage construction. For maximum water

temperature up to 400C.

 Other industrial applications

Global data

Brand YIFANG

Standard EN 50525-2-21, IEC 60 245

Design

Conductors: Bare annealed copper conductor, flexible, class 5 in accordance IEC 60228.
Insulation: Ethylene-Propylene Rubber thermosetting compound.
Sheath: Double layer, thermosetting compound.
Inner layer: Ethylene-Propylene Rubber (EPR) compound.
Outer layer: Chlorinated Polyethylene (CPE) heavy duty, flame retardant compound.
Colour of sheath: Blue or other colours available upon request.
Core identification: According to HD 308 S2.
Test voltage 50Hz: 2500V
Flame propagation: IEC 60332-1-2.
Minimum bending radius: For cable diameter D (mm) : D < 8 8 < D < 12 12 < D < 20
For fixed installation: 3 D 3 D 4 D
At inlet of portable appliance or mobile equipment. No mechanical load on cable
4 D 4 D 5 D
Under mechanical load 6 D 6 D 6 D

Features

 Maximum conductor operating temperature: +90°C

 Lowest ambient temperature for fixed installation: -40°C

 Maximum short-circuit conductor temperature: +250°C

 Pulling strength: not exceeding 15 N/mm2

 Excellent water resistant up to 100 m water depth

 Excellent flexibility

 Ozone, sun, weather, heat resistant

 Ink jet or indent printed for easy identificati

Standard length cable packing:

500 or 1000 m on drums. Other forms of packaging are available on request.

Specification

No.& AREA

OF CONDC

MAX.

DIAMETER

OF

STRANDS

NOMINAL

THICKNESS

OF

INSULATION

NOMINAL

THICKNESS

OF DOUBLE

LAYER

JACKET

APPROX.

OUTER

DIAMETER

APPROX.

NET

WEIGHT

MAX.

CONDUCTOR

RESISTANCE

AT 20℃

Current-currying

capactiy

nxmm2 mm mm mm mm kg/km Ω/km A
4X6+2X1.5 0.31 1.0 1.0+1.5 21.4 588 330 50
7X6+2X1.5 0.31 1.0 1.0+1.5 22.4 806 330 55
4X10+2X1.5 0.41 1.2 2.2+3.2 26.8 1052 191 67
4X16+2X1.5 0.41 1.2 2.2+3.2 29.6 1371 121 91
4X25+2X1.5 0.41 1.4 2.2+3.2 33.4 1880 0.78 121
4X35+2X1.5 0.41 1.4 2.2+3.4 36.2 2347 0.554 149
4X50+2X1.5 0.41 1.6 2.2+3.4 40.3 3000 0.386 183

At 30 C in air for 85 C conductor temperature