LV AAAC ACSR Bundle Conductor Cable For Overhead Lines
LV AAAC ACSR Bundle Conductor Cable For Overhead Lines image
LV AAAC ACSR Bundle Conductor Cable For Overhead Lines
Bundle Conductor Cable is a very innovative concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system. It includes aerial bundle cable (ABC cable), covered line wire and service drop cable. It provides a higher safety and reliability, lower power losses, and ultimate system economy by reducing installation, maintenance and operative cost.Low voltage aerial cable is designed to supply 600/1000-volt aerial service for temporary service at construction sites.
DIMENSIONS
Number of conductors and nominal cross section | Thickness of insulation M/N/R | Diamete r of bundle approx. | Allowed current in power supply networks | Allowed current in distribution networks | Аl/R | ||
Mass of Аl cores approx. | Cable weight approx. | ||||||
n х mm2 | mm | mm | А | А | kg/km | kg/km | |
walls/air/facades | |||||||
2×16 | 1.2 | 15 | – | 72 / 93 / 83 | 91 | 125 | |
2×25 | 1.4 | 18 | – | 95 / 122 / 111 | 142 | 165 | |
4×16 | 1.2 | 18 | – | 63 / 83 / 75 | 183 | 260 | |
4×25 | 1.4 | 22 | – | 83 / 111 / 99 | 285 | 395 | |
3×25+54.6Alm | 1.4/1.6 | 30 | 112 | – | 369 | 505 | |
3×25+54.6Alm+Kx16 | 1.4/1.6/1.2 | 30 | 112 / 83 | – | 460 | 635 | |
3×35+54.6Alm | 1.6/1.6 | 33 | 138 | – | 455 | 615 | |
3×35+54.6Alm+Kx16 | 1.6/1.6/1.4 | 33 | 138 / 83 | – | 546 | 745 | |
3×50+54.6Alm | 1.6/1.6 | 36 | 168 | – | 583 | 725 | |
3×50+54.6Alm+Kx16 | 1.6/1.6/1.2 | 36 | 168 / 93 | – | 674 | 860 | |
3×50+54.6Alm+Kx25 | 1.6/1.6/1.4 | 36 | 168 / 111 | – | 725 | 925 | |
3×70+54.6Alm | 1.8/1.6 | 37 | 213 | – | 754 | 950 | |
3×70+54.6Alm+Kx16 | 1.8/1.6/1.2 | 40 | 213 / 83 | – | 845 | 1080 | |
3×70+54.6Alm+Kx25 | 1.8/1.6/1.4 | 40 | 213 / 111 | – | 896 | 1150 | |
3×70+70Alm | 1.8/1.5 | 41 | 213 | – | 798 | 984 | |
3×70+70Alm+Kx16 | 1.8/1.5/1.2 | 41 | 213 / 83 | – | 889 | 1115 | |
3×70+70Alm+Kx25 | 1.8/1.5/1.4 | 41 | 213 / 111 | – | 940 | 1185 | |
3×95+54.6Alm | 1.8/1.6/ | 44 | 258 | – | 967 | 1195 | |
3×95+54.6Alm+Kx16 | 1.8/1.6/1.2 | 44 | 258 / 83 | – | 1059 | 1325 | |
3×95+54.6Alm+Kx25 | 1.8/1.6/1.4 | 44 | 258 / 111 | – | 1110 | 1355 | |
3×95+70Alm | 1.8/1.5 | 44 | 258 | – | 1011 | 1355 | |
3×95+70Alm+Kx16 | 1.8/1.5/1.2 | 44 | 258 / 83 | – | 1102 | 1615 | |
3×95+70Alm+Kx25 | 1.8/1.5/1.4 | 44 | 258 / 111 | – | 1154 | 1485 | |
3×120+70Alm | 1.8/1.5 | 46 | 300 | – | 1225 | 1445 | |
3×120+70Alm+Kx16 | 1.8/1.5/1.2 | 46 | 300 / 83 | – | 4828 | 1575 | |
3×120+70Alm+Kx25 | 1.8/1.5/1.4 | 46 | 300 /111 | – | 1368 | 1610 | |
3×120+95Alm | 1.8/1.6 | 47 | 300 | – | 1296 | 1535 | |
3×120+95Alm+Kx16 | 1.8/1.6/1.2 | 47 | 300 / 83 | – | 1387 | 1660 | |
3×120+95Alm+Kx25 | 1.8/1.6/1.4 | 47 | 300 / 111 | – | 1439 | 1735 |