Low Voltage Single Core Fire Resistant Cable Pvc Sheath Xlpe Insulation Cable

 China Low Voltage Single Core Fire Resistant Cable Pvc Sheath Xlpe Insulation Cable supplier

Low Voltage Single Core Fire Resistant Cable Pvc Sheath Xlpe Insulation Cable image

Get a Quote Email to us

Brand Name :
SHANCABLE

Model Number :
NH-YJV

Certification :
ROHS CE KEMA

Place of Origin :
SHANGHAI, CHINA

MOQ :
500

Price :
0.98-59.6 US$/M

Supply Ability :
20km/month

Delivery Time :
10-15 days

Packaging Details :
steel wooden drum

Conductor :
Copper

Insulation :
XLPE

Wrapping tape :
LSOH bending tape

Sheath :
PVC

Core :
Single core

Standards :
IEC60332,IEC60502, IEC60228

Fire resistance :
Mica-Tape

Fire resistant low voltage single core cable pvc sheath xlpe insulation cable for translate electric

Model no.: NH-YJV

Conductor material: Copper(Cu)

Condutor type: Stranded

No. of cores: Single core

Cross section area: 10-400mm2

Rated voltage:0.6/1KV

Insulation: Irradiated XLPE

Jacket: Low smoke zero halogen fire resistance flame retardant PE/PO or PVC

Cable identification

– Cores: Red, yellow, blue, black, green/yellow (by color tape, except green-yellow core)

– Outer sheath: orange or as order

Normal construction

3+1,4+1,3+2,1core,2cores,3cores,4cores,5cores and etc.

Norminal cross-section of conductor(mm2):

1,1.5,2.5,4,6,10,16,25,35,50,70,95,120,150,185,240,300, 400

Appliations

1.Application scope

LSOH or LSZH fire resistant Wire and Cable can produce little smoke and innocuous gas without halogen when combustion.

The cable can be widely used in high-rise building, hospital,large-sized library, gymnasium, disaster prevention command and dispatchbuilding, station, civil airfield, passenger waiting room,emphases cultural relic, subway, underground shop or the crowded public concourses.

2.Application characteristics

1)Rated voltage UO/U:450V/750V; AC polyolefin UO/U is 0.6/1kv;

2)Temperature range during operation:-20 centigrade-90 centigrade or -40 centigrade-105 centigrade;

3)Recommended bending radius:non-armoured cable should not less than 6 times of cable diameter, armoured or copper tape shielded cable should not less than 12 times of cable diameter.

Standards

BS 7846; IEC 60331; BS 6387

Construction

Cu/Mica/XLPE/LSZH/SWA/LSZH

(1) Conductor: Plain annealed copper (class 2, normal
stranded or compact stranded)

(2) Fire barrier: Mica tape

(3) Insulation: XLPE

(4) Filler, binder and inner covering: PP, PET, LSZH

(5) Armour: Steel wire

(6) Outer sheath: LSZH

Characteristics

– Voltage rate: 0.6/1kV

– Maximum conductor temperature: 900C in normal operation; 2500C in short-circuit for 5s max.

– Minimum bend radius: 12xD (twelve times overall diamerter of cable)

– Fire resistant: IEC 60331; BS 6387

– Flame retardant: BS EN 60332-1; IEC 60332-1

– Corrosive and acid gas: BS 7846; BS 50267-2-1; IEC 60754-1&2

Smoke emission: BS 7846; BS EN 50268-2; IEC 61034-2

Notes: * All conductor in accordance with IEC 60228. Compacted conductor (C.C) or non-compacted depend on order.

• Besides the above mentioned list we can also provide other sizes depending on customer’s requirement.

We are China Low Voltage Single Core Fire Resistant Cable Pvc Sheath Xlpe Insulation Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION