Single Core PVC Wire
Low Voltage Copper buliding wire for use in the internal wiring of devices or for conduit
H05V-U/H07V-U Copper building wire
Single-conductor hook-up wires with a solid bare copper core. These insulated wires are determined for the installation to the inside of apparatus as well as for the protective laying to the lightings, in dry rooms, in production facilities, switch and distributor boards, in tubes, under and surface mounting of plasters.
H05V-K / H07V-K Copper lead wire
A range of PVC single core cables for use in the internal wiring of devices or for conduit or trunking wiring. Available from 0.5mm² up to 240mm² in a various range of colours.
H07V-R stranded copper building wire 450/750 Volts
PVC-insulated conductors for fixed installations. Mainly used in power and lighting circuits, both domestic and commercial applications. They are also used in the internal wiring of appliances.
H05V2-U heat resistance solid copper building wire 300/500 V
H05V2-U is a lead free, PVC insulated, house wiring cable with one circular copper conductor. with maximum 90°C conductor temperature.
H05V2-K heat resistance flexible wire copper stranded
H05V2-K is a lead free, PVC insulated, connecting cable with one circular, multi stranded copper conductor with maximum 90°C conductor temperature.
H05Z-K/H07Z-K halogen free flexible stranded copper wire
A range of Harmonised approved low smoke halogen free single core cables for use in applications where the protection of human life and the environment is at risk from the formation of acid from fire conditions. Available from 0.5 mm² up to 95 mm² in a various range of colours.
Colors available:
black, blue, brown, gray, yellow, green, white, orange, red, dark blue, green-yellow
H05V-U copper building wire — 300 / 500 V PVC Insulated wire (Solid Conductor)
Conductor cross section |
minimum wall-thickness |
Outer Ø min. – max. |
Weight approx. |
Maximum |
Conductor DC resistant at 20°C |
Standard |
---|---|---|---|---|---|---|
mm² |
mm |
mm |
kg / km |
A |
Ω/km |
m /coil |
0.5 |
0.6 |
1,9 – 2,3 |
9 |
12 |
36 |
100 |
0.75 |
0.6 |
2.1 – 2.5 |
12 |
15 |
24.5 |
100 |
1 |
0.6 |
2.2 – 2.7 |
15 |
19 |
18.1 |
100 |
H05V2-U copper building wire 300/500 V PVC Insulated,90 °C heat-resistant
Conductor cross section |
minimum wall-thickness |
Outer Ø min. – max. |
Weight approx. |
Maximum |
Conductor DC resistant at 20°C |
Standard |
---|---|---|---|---|---|---|
mm² |
mm |
mm |
kg / km |
A |
Ω/km |
m /coil |
0.5 |
0.6 |
1.9 – 2.3 |
8.3 |
13 |
36 |
100 |
0.75 |
0.6 |
2.1 – 2.5 |
11 |
17 |
24.5 |
100 |
1.0 |
0.6 |
2.2 – 2.7 |
13.8 |
20 |
18.1 |
100 |
1.5 |
0.7 |
2.6 – 3.2 |
20.1 |
25 |
12.1 |
100 |
2.5 |
0.8 |
3.2 – 3.9 |
32 |
34 |
7.41 |
100 |
H07V-U copper building wire —450 / 750 V PVC Insulated Single core wire (Solid Conductor)
Conductor cross section |
minimum wall-thickness |
Outer Ø min. – max. |
Weight approx. |
Maximum |
Conductor DC resistant at 20°C |
Standard |
---|---|---|---|---|---|---|
mm² |
mm |
mm |
kg / km |
A |
Ω/km |
m /coil |
1.5 |
0.7 |
2.6 – 3.2 |
19.9 |
25 |
12.1 |
100 |
2.5 |
0.8 |
3.2 – 3.9 |
31.4 |
34 |
7.41 |
100 |
4 |
0.8 |
3.6 – 4.4 |
49 |
44.5 |
4.61 |
100 |
6 |
0.8 |
4.3 – 5.0 |
66 |
58 |
3.08 |
100 |
10 |
1 |
5.3 – 6.4 |
11.4 |
79.5 |
1.83 |
100 |
H07V-R (6491X) PVC-insulated stranded copper building wire single core wire 70 °C
Conductor cross section |
minimum wall-thickness |
Outer Ø min. – max. |
Weight approx. |
Maximum |
Conductor DC resistant at 20°C |
Standard |
---|---|---|---|---|---|---|
mm² |
mm |
mm |
kg / km |
A |
Ω/km |
m /coil |
1.5 |
0.7 |
2.7 – 3.3 |
21 |
25 |
12.1 |
100 |
2.5 |
0.8 |
3.3 – 4.0 |
33.1 |
34 |
7.41 |
100 |
4 |
0.8 |
3.8 – 4.6 |
49 |
44.5 |
4.61 |
100 |
6 |
0.8 |
4.3 – 5.2 |
69.4 |
58 |
3.08 |
100 |
10 |
1 |
5.6 – 6.7 |
116 |
79.5 |
1.83 |
100 |
16 |
1 |
6.4 – 7.8 |
175 |
111 |
1.15 |
100 |
25 |
1.2 |
8.1 – 9.7 |
275 |
146 |
0.727 |
100 |
35 |
1.2 |
9.0 – 10.9 |
372 |
180 |
0.524 |
100 |
50 |
1.4 |
10.6 – 12.8 |
496 |
225 |
0.387 |
100 |
70 |
1.4 |
12.1 – 14.6 |
701 |
280 |
0.268 |
100 |
95 |
1.6 |
14.1 – 17.1 |
969 |
344 |
0.193 |
100 |
120 |
1.6 |
15.6 – 18.8 |
1202 |
397.5 |
0.153 |
100 |
150 |
1.8 |
17.3 – 20.9 |
1478 |
455 |
0.124 |
100 |
185 |
2 |
19.3 – 23.3 |
1853 |
519 |
0.0991 |
100 |
240 |
2.2 |
22.0 – 26.6 |
2417 |
541 |
0.0754 |
100 |
300 |
2.4 |
24.5 – 29.6 |
3024 |
636 |
0.0601 |
100 |
400 |
2.6 |
27.5 – 33.2 |
3825 |
727 |
0.047 |
100 |
H05V-K copper building wire 300 / 500 V PVC-Single Cores, fine wire stranded
Conductor cross section |
minimum wall-thickness |
Outer Ø min. – max. |
Weight approx. |
Maximum |
Conductor DC resistant at 20°C |
Standard |
---|---|---|---|---|---|---|
mm² |
mm |
mm |
kg / km |
A |
Ω/km |
m /coil |
0.5 |
0.6 |
2.1 – 2.5 |
9 |
13.3 |
39 |
100 |
0.75 |
0.6 |
2.2 – 2.7 |
12.2 |
17 |
26 |
100 |
1 |
0.6 |
2.4 – 2.8 |
14.8 |
20 |
19.5 |
100 |
H07V-K copper building wire 450 / 750 V PVC-Single Cores, fine wire stranded
Conductor cross-section |
minimum wall-thickness |
Outer Ø min. – max. |
Weight approx. |
Minimum at 70 ℃ |
Maximum |
Conductor DC resistant at 20°C |
Standard |
---|---|---|---|---|---|---|---|
mm² |
mm |
mm |
kg / km |
MΩ.km |
A |
Ω/km |
m |
1.5 |
0.7 |
2.8 – 3.4 |
19 |
0.010 |
16 |
13.3 |
100 |
2.5 |
0.8 |
3.4 – 4.1 |
30 |
0.009 |
20 |
7.98 |
100 |
4 |
0.8 |
3.9 – 4.8 |
44 |
0.007 |
25 |
4.95 |
100 |
6 |
0.8 |
4.4 – 5.3 |
63 |
0.006 |
36 |
3.3 |
100 |
10 |
1 |
5.7 – 6.8 |
112 |
0.0056 |
50 |
1.91 |
100 |
16 |
1 |
6.7 – 8.1 |
169 |
0.0046 |
68 |
1.21 |
100 |
25 |
1.2 |
8.4 – 10.2 |
251 |
0.0044 |
89 |
0.78 |
100 |
35 |
1.2 |
9.7 – 11.7 |
369 |
0.0038 |
110 |
0.554 |
1000 |
50 |
1.4 |
11.5 – 13.9 |
528 |
0.0037 |
134 |
0.386 |
1000 |
70 |
1.4 |
13.2 – 16.0 |
756.5 |
0.0032 |
171 |
0.272 |
1000 |
95 |
1.6 |
15.1 – 18.2 |
988.1 |
0.0032 |
207 |
0.206 |
1000 |
120 |
1.6 |
16.7 – 20.2 |
1205.7 |
0.0029 |
239 |
0.161 |
1000 |
150 |
1.8 |
18.6 – 22.5 |
1529.9 |
0.0029 |
275 |
0.129 |
1000 |
185 |
2 |
20.6 – 24.9 |
1883.5 |
0.0029 |
314 |
0.106 |
1000 |
240 |
2.2 |
23.5 – 28.4 |
2394.5 |
0.0028 |
369 |
0.0801 |
1000 |
H05V2-K copper building wire 300/500 V PVC-Single Cores, 90 °C heat-resistant
Conductor cross section |
minimum wall-thickness |
Outer Ø min. – max. |
Weight approx. |
Maximum |
Conductor DC resistant at 20°C |
Standard |
---|---|---|---|---|---|---|
mm² |
mm |
mm |
kg / km |
A |
Ω/km |
m /coil |
0.5 |
0.6 |
2.1 – 2.5 |
9 |
13.3 |
39 |
100 |
0.75 |
0.6 |
2.2 – 2.7 |
12 |
17 |
26 |
100 |
1.0 |
0.6 |
2.4 – 2.8 |
15 |
20 |
19.5 |
100 |
1.5 |
0.7 |
2.8 – 3.4 |
22 |
25.4 |
13.3 |
100 |
2.5 |
0.8 |
3.4 – 4.1 |
34 |
34.5 |
7.98 |
100 |
* Dimensions and specifications may be changed without prior notice.
Designation |
Nominal Voltage U0 / U (V) |
According to DIN VDE 0285-525 |
According to design to IEC |
Links |
---|---|---|---|---|
PVC-wring cables single wire |
300/500 |
H05V-U |
60227 IEC 05 |
More >> |
PVC-wring cables fine wires |
300/500 |
H05V-K |
60227 IEC 06 |
More >> |
PVC-insulated cables single wire |
450/750 |
H07V-U |
60227 IEC 01 |
More >> |
PVC-insulated cables Multi-stranded wires |
450/750 |
H07V-R |
60227 IEC 01 |
More >> |
PVC-insulated cables fine wires |
450/750 |
H07V-K |
60227 IEC 02 |
More >> |
Multi-core PVC-Sheathed cables round |
300/300 |
H03VV-F |
60227 IEC 52 |
More>> |
Multi-core PVC-Sheathed flexible cables round |
300/500 |
H05VV-F |
60227 IEC 53 |
More >> |
Light PVC sheathed cables for fixed wiring |
300/500 |
— |
60227 IEC 10 |
More >> |
PVC Insulated Flexible Twin Twisted Electrical Wire |
300/300 |
— |
60227 IEC 43 |
More >> |
Packaging
– Coil in foil 100m (as of 10 mm2)
– Coil in cardboard (100m) as required (up to 6 mm2)
– Drum (as of 35 mm2)
– Other package as required
Cable Drum Data
CABLE DRUMS |
D1=Flange Diameter(mm) |
W=Useful Width (mm) |
D2=Barrel Diameter(mm) |
|
1000 |
700 |
500 |
1100 |
700 |
550 |
|
1200 |
700 |
600 |
|
1400 |
750 |
710 |
|
1600 |
900 |
900 |
|
1800 |
1120 |
1000 |
|
2400 |
1150 |
1300 |
Delivery Port:
|
|
|
Port of Shenzhen |
Port of Hongkong |
Port of Guangzhou |
Products Certificates
CE |
IEC CB TEST CERTIFICATE |
China Compulsory Certificate, 3C |
|
|
|
– Certificate No. : CE170103005260 – Certified through China quality certification centre |
– Certificate No. : CN39331 – Certified through China quality certification centre |
– Certificate No. : 2002010105011347 – Certified through China quality certification centre |
* All substances of the cable meet the requirements of RoHS Directive-compliant
Shenzhen chengtiantai cable operates certified management systems compliant with:
Certificate |
Information |
|
|
ISO 9001:2008 Quality management systems |
– Certificat ISO 9001:2008 |
|
ISO 14001:2004 Environmental management systems |
– Certificat ISO 14001:2004 – Shenzhen chengtiantai cable industry development Co.Ltd. ; – Certified through Guangdong quality Testing CTC Certification Co.Ltd.; – Valid until 9th January 2022 |
|
OHSAS 18001:2007 Assessment specification for occupational health & safety management systemsenvironmental management systems |
– Certificat OHSAS 18001:2007 |
Our production in numbers
|
|
● Cable production started 1983 ● Sales in 2016 about 500 million USD ● 100,000 m2 Production area ● 8 workshop |