Low Relaxation Galvanized Wire Cable , Steel Cable Wire 1000-1550 MPA Tensile Strength
Low Relaxation Galvanized Wire Cable , Steel Cable Wire 1000-1550 MPA Tensile Strength image
Brand Name :
Litong Global
Model Number :
LT170210
Certification :
ISO9001-2008
Place of Origin :
Anhui,China
MOQ :
Negotiable
Price :
Negotiable
Supply Ability :
400tons/day
Packaging Details :
Standard export seaworthy packing in coil or on drum
Material :
High Carbon Wire Rod
zinc-coating :
100-300g/m2
Tensile Strength :
1000-1550MPA
Size :
1.57-4.8mm
Packing :
100-300kg/coil
Loading Capacity :
25tons/20″
Galvanized Steel Core Wire for ACSR Conductor
1) Profile: High Tensile Galvanized Steel Wire or ACSR Core Wire may be supplied as single wire or also in seven or ninetheen strands. Manufactured conforming to various international standards to specify requirement of customers.
2) Application: Used for mechanical re-inforcement in the manufacture of aluminum conductor steel reinforced (ACSR) Cable & Conductor ACSR Core wire is used in reinforcement of aluminium conductors used in distribution and transmission of electricity.
3)Standard:
ASTM B498, IEC60888,ASTM A 475,ASTM 363,ASTM B 500,BS 183 etc.
Specification
EN 50189 Standard
Table 1. Initial Settings for Determining Stress 1% Extension | |||
Nominal Wire Diameter, mm | Initial Stress, N/mm2 | Initial setting of extensometer for a gauge length of 250mm2 | |
1.24 | 2.25 | 100 | 0.125 |
2.25 | 3 | 200 | 0.25 |
3 | 4.75 | 300 | 0.375 |
4.75 | 5.5 | 400 | 0.5 |
For other gauge lengths, multiply the initial setting by the gauge length in mm divided by 250. |
Table 2. Zinc Coating Requirements | |||||||||||
Nominal Wire Diameter, mm | Class A | Class B | Class C | Class D | Class E | ||||||
Over | Up to and incl. | Min. mass of Zn g/m2 | Min. no. of one minute dips | Min. mass of Zn g/m2 | Min. no. of one minute dips | Min. mass of Zn g/m2 | Min. no. of one minute dips | Min. mass of Zn g/m2 | Min. no. of one minute dips | Min. mass of Zn g/m2 | Min. no. of one minute dips |
1.24 | 1.5 | 185 | 2 | 370 | 3.5 | 150 | 1 | 365 | 3 | 185 | 2 |
1.5 | 1.75 | 200 | 2 | 400 | 3.5 | 160 | 1.5 | 460 | 3.5 | 200 | 2 |
1.75 | 2 | 215 | 2.5 | 430 | 4 | 175 | 2 | 550 | 4 | 215 | 2.5 |
2 | 2.25 | 215 | 2.5 | 430 | 4 | 175 | 2 | 550 | 4 | 250 | 3.5 |
2.25 | 2.75 | 230 | 3 | 460 | 4 | 190 | 2.5 | 640 | 5 | 250 | 3.5 |
2.75 | 3 | 230 | 3 | 460 | 4 | 190 | 2.5 | 640 | 5 | 250 | 3.5 |
3 | 3.5 | 245 | 3.5 | 490 | 4 | 205 | 3 | 730 | 6 | 250 | 3.5 |
3.5 | 4.25 | 260 | 3.5 | 520 | 4 | 260 | 3.5 | 730 | 6 | 260 | 3.5 |
4.25 | 4.75 | 275 | 4 | 550 | 4 | 275 | 4 | 775 | 6 | 275 | 4 |
4.75 | 5 | 200 | 4 | 580 | 5 | 290 | 4 | 825 | 6 | 290 | 4 |
5 | 5.25 | 290 | 4 | 580 | 5 | 290 | 4 | 825 | 6 | 290 | 4 |
5.25 | 5.5 | 290 | 4 | 580 | 5 | 290 | 4 | 825 | 6 | 290 | 4 |
Table 3. Mechanical Properties of ST1A Wires | |||||||
Nominal wire diameter mm | Diameter tolerance | Stress at 1% extension, MPa | Tensile strength, MPa | Elongation on 250mm | Mandrel diameter for wrapping test | No. of torsion twists | |
Over | Up to and incl. | mm | N/MM2 | N/MM2 | % | ||
Min. | Min. | Min. | xd | Min. | |||
1.24 | 1.5 | ±0.03 | 1170 | 1400 | 3 | 1 | 18 |
1.5 | 1.75 | ±0.03 | 1170 | 1400 | 3 | 1 | 18 |
1.75 | 2.25 | ±0.03 | 1170 | 1400 | 3 | 1 | 18 |
2.25 | 2.75 | ±0.04 | 1140 | 1350 | 3 | 1 | 16 |
2.75 | 3 | ±0.05 | 1140 | 1350 | 3.5 | 1 | 16 |
3 | 3.5 | ±0.05 | 1100 | 1300 | 3.5 | 1 | 14 |
3.5 | 4.25 | ±0.06 | 1100 | 1300 | 4 | 1 | 12 |
4.25 | 4.75 | ±0.06 | 1100 | 1300 | 4 | 1 | 12 |
4.75 | 5.5 | ±0.07 | 1100 | 1300 | 4 | 1 | 12 |
Table 4. Mechanical properties of ST2B Wires | ||||||
Nominal wire diameter mm | Diameter tolerance | Stress at 1% extension, MPa | Tensile strength, MPa | Elongation on 250mm | Mandrel diameter for wrapping test | |
Over | Up to and incl. | mm | N/MM2 | N/MM2 | ||
1.24 | 1.5 | ±0.05 | 1100 | 1300 | 4 | 1 |
1.5 | 1.75 | ±0.05 | 1100 | 1300 | 4 | 1 |
1.75 | 2.25 | ±0.05 | 1100 | 1300 | 4 | 1 |
2.25 | 2.75 | ±0.06 | 1070 | 1250 | 4 | 1 |
2.75 | 3 | ±0.06 | 1070 | 1250 | 4 | 1 |
3 | 3.5 | ±0.07 | 1000 | 1200 | 4 | 1 |
3.5 | 4.25 | ±0.09 | 1000 | 1200 | 4 | 1 |
4.25 | 4.75 | ±0.10 | 1000 | 1200 | 4 | 1 |
4.75 | 5.5 | ±0.11 | 1000 | 1200 | 4 |
BS4565-1990 Standard
Table 1. Initial Settings for Determining Stress 1% Extension | |||
Nominal Diameter of Galvanized Steel Wire | Initial Stress N/mm2 | Initial Setting of Extensometer mm/mm | |
> | < | ||
mm | mm | ||
1.18 | 2.24 | 95 | 0.05 |
2.24 | 3.15 | 190 | 0.10 |
3.15 | 5.00 | 285 | 0.15 |
Table 2. Tensile Strength and Stress at 1% Elongation | |||
Nominal Diameter of Galvanized Steel Wire | Tensile Strength minimum N/mm2 | Stress at 1% elongation minimum N/mm2 | |
> | < | ||
mm | mm | ||
1.18 | 2.24 | 1400 | 1180 |
2.24 | 3.15 | 1320 | 1140 |
3.15 | 5.00 | 1320 | 1100 |
Table 3. Properties for High Strength Galvanized Steel Wire for ACSR | ||||||||||
Tensile strength grade N/mm2, min. | 1550 | 1700 | 1800 | |||||||
Nominal diameter of galvanized wire | Min. stress at 1% elongation | Min. elongation L0+=200mm% | Steel wrap test dia. | Min. stress at 1% elongation | Min. elongation L0+=200mm% | Steel Wrap test dia. | Min. stress at 1% elongation | Min. elongation L0+=200mm% | Steel wrap test dia. | |
> | ≤ | |||||||||
mm | mm | |||||||||
1.18 | 1.32 | 1260 | 3.0 | 1d | 1320 | 3.0 | 2d | 1370 | 3.0 | 3d |
1.32 | 1.80 | 1260 | 3.5 | 1d | 1320 | 3.0 | 2d | 1370 | 3.0 | 3d |
1.80 | 2.24 | 1260 | 3.5 | 2d | 1320 | 3.0 | 2d | 1370 | 3.0 | 3d |
2.24 | 2.72 | 1260 | 3.5 | 2d | 1320 | 3.5 | 3d | 1370 | 3.0 | 3d |
2.72 | 2.90 | 1260 | 3.5 | 2d | 1320 | 3.5 | 3d | 1370 | 3.0 | 3d |
2.90 | 4.00 | 1220 | 4.0 | 3d | 1280 | 3.5 | 3d | – | – | – |
4.00 | 5.00 | 1220 | 4.0 | 3d | – | – | – | – | – | – |
d=Nominal diameter of galvanized wire | ||||||||||
L0= Original Gauge Length |
Table 4. Conversions of Tensile Strength and Stress at 1% Elongation | |
N/MM2 | tonf/in2 |
1100 | 71.2 |
1140 | 73.8 |
1180 | 76.4 |
1220 | 79.0 |
1260 | 81.6 |
1280 | 82.9 |
1320 | 85.5 |
1370 | 88.7 |
1400 | 9.07 |
1550 | 100.4 |
1700 | 110.1 |
1800 | 116.6 |
ASTMB498B/498M-2002 Standard
Table 1. Zinc Coating | |||
Specified Diameter of Coated Wre | Class A | Class B | Class C |
1.6-1.9 | 210 | 420 | 630 |
>1.9-2.3 | 220 | 440 | 660 |
>2.3-2.7 | 230 | 460 | 690 |
>2.7-3.1 | 240 | 480 | 720 |
>3.1-3.5 | 260 | 520 | 780 |
>3.5-3.9 | 270 | 540 | 810 |
>3.9-4.5 | 275 | 550 | 825 |
>4.5-4.8 | 300 | 600 | 900 |
Table 2. Tensile Requirements | |||||||||
Specified Diameter | Stress at 1 % Extension min Mpa | Ultimate Tensile Strength min MPA | Elongation in 250mm, min, 1% | ||||||
Class A | Class B | Class C | Class A | Class B | Class C | Class A | Class B | Class C | |
1.6-2.3 | 1310 | 1240 | 1170 | 1450 | 1380 | 1310 | 3 | 3 | 3 |
>2.3-3.05 | 1280 | 1210 | 1140 | 1410 | 1340 | 1280 | 3.5 | 3 | 3 |
>3.05-3.6 | 1240 | 1170 | 1100 | 1410 | 1340 | 1280 | 4 | 3 | 3 |
>3.6-4.8 | 1170 | 1100 | 1070 | 1380 | 1280 | 1240 | 4 | 4 | 4 |
Table 3. Initial Settings for Determining Stress 1% Extension | ||
Specified Diameter, mm | Initial Stress, MPA | Initial Setting of Extensometer, mm/mm |
1.6-2.3 | 100 | 0.0005(0.05% extension) |
>2.3-3.05 | 190 | 0.0010(0.10% extension) |
>3.05-4.8 | 290 | 0.0015(0.15% extension) |
Table 4. Mandrel Size for Adherence Test | |
Specified Wire Diameter,mm | Ratio of Mandrel Diameter to Wire Diameter |
1.6-2.3 | 3 |
>2.3-3.05 | 4 |
>3.05-4.8 | 5 |
Table 5. Permissible Variations in Diameter of Zinc-Coated Steel Wire | ||
Specified Diameter, mm | Permissible Variation, mm | |
Plus | Minus | |
1.6-2.3 | 0.04 | 0.03 |
>2.3-3.05 | 0.05 | 0.05 |
>3.05-3.6 | 0.08 | 0.05 |
>3.6-4.8 | 0.1 | 0.08 |
ASTM A475 Standard
Dia. of strand, in(mm) | Minimum Breaking Strength of Strand,1bf(kN) | Weight of Zine Coating, g/m2 | ||
High Strength Grade | Extra High Strength Grade | CLASS A | CLASS B | |
3/16(4.76) | 2850(12.677) | 3990(17.748) | 153 | / |
1/4(6.35) | 2850(21.129) | 6650(29.581) | 183 | 366 |
5/16(7.94) | 8000(35.586) | 11200(49.820) | 244 | 488 |
3/8(9.52) | 10800(48.040) | 15400(68.503) | 259 | 519 |
7/16(11.11) | 14500(64.499) | 20800(92.523) | 275 | 549 |
1/2(12.70) | 18800(83.627) | 26900(119.657) | 275 | 549 |
ASTM B498 Standard
Dia of Wire, mm | Tensile Strength, Mpa | Stress at 1% Extension, Mpa | Coating, g/m2 | |
CLASS A | CLASS B | |||
0.80-1.57 | 1000-1550 | / | 50-153 | / |
1.57-1.90 | 1000-1550 | / | 153-210 | / |
1.90-2.30 | 1000-1550 | 1310 | 220 | 440 |
2.30-2.70 | 1000-1550 | 1280 | 230 | 460 |
2.70-3.10 | 1000-1550 | 1280 | 240 | 480 |
3.10-3.50 | 1000-1550 | 1240 | 260 | 520 |
3.50-3.90 | 1000-1550 | 1170 | 270 | 540 |
3.90-4.50 | 1000-1550 | 1170 | 275 | 550 |
4.50-4.80 | 1000-1550 | 1170 | 300 | 600 |
Production process
Certificate
Exhibition
Customers Visit
Packing & Loading
Trade Terms
Min Order Qty: 1FCL / 25T
Delivery Time: 10-15 days
Price Terms: FOB CFR CIF
Payment Terms: TT / LC
FAQ
Q:If found the product with substardard quality.How can you solve it?
A:The buyer will be required to submit proof file,picture,ideo of the said substandard cargo send to us first. We can also send our engineer to your filed to check it directly,if need any.
Q:If sample available?
A:Yes,we can offer sample free of charge.But the express freight should be on buyer’s account.
Q:If I order big quantity,what’s the good price?
A:Please send the details enquiry to us ,such as the Item Number,Quantity for each item, Quality request,Logo,Payment Terms,Transport method,Discharge place etc.We will make the accurate quotation to you as soon as possible.
If you are interested in our products, pls feel free to tell me the diameter or nominal section area or the nick name to me. Then,I will send our best quotation to you.
Contact us:
Attn: Nancy
E-mail:[email protected]
What'app:86-13855514957
Cell:86-13855514957
Skype:nancylsl
We are China Low Relaxation Galvanized Wire Cable , Steel Cable Wire 1000-1550 MPA Tensile Strength manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: galvanised steel wire, Galvanized Steel Wire, zinc coated wire