Indoor PVC Insulated Flexible Cable Compact Stranded Copper Conductor

 China Indoor PVC Insulated Flexible Cable Compact Stranded Copper Conductor supplier

Indoor PVC Insulated Flexible Cable Compact Stranded Copper Conductor image

Get a Quote Email to us

Brand Name :
CHINT

Model Number :
60227IEC02(RV)

Certification :
CE/CCC/ROSH

Place of Origin :
CHINA

MOQ :
Negotiable

Price :
Negotiable

Supply Ability :
1000km/month

Packaging Details :
100m/roll or drum

Insulation :
PVC

Conductor :
Class 5 as per IEC 60228

Standard :
IEC 60227-3:1997

Marking :
printing or embossing

Voltage :
450/750V

Sheath :
Non-sheathed

H05v-K / H07v-K Flexible PVC Insulated Copper Wire Non Sheated Single Core Cables

Description:

Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V——Non-sheathed cables for fixed wiring

Fixed laying power supply connection for Electrical equipment.

Constructions

Conductor : Compact stranded copper conductor, Cl.5 as per IEC 60228

Insulation : PVC(Polyvinyl chloride) rated at 70 ℃

Figure 1 Product structure sketch

Note:1- Conductor; 2- Insulation.

Note:

Insulation identification as per standards or customer requirement

Applications

Indoor, distribution cabinet, electrical connection.

Standards

International: IEC 60227-3:1997

China: GB∕T 5023.3-2008

Other standards such as BS,VDE and ICEA upon request

Technical data

Rated voltage: See Table 3.

Max. Operating Temp.: 70 ℃.

Min. Ambient Temp.: 20±10 ℃

Table 2 – Minimum recommended bending radii at cable temperature of (20±10)

Cable type Installations minimum bending radius
Cable diameter
mm
Cable diameter
mm
Cable diameter
mm
Cable diameter
mm
Flexible cable (thermoplastic, e.g. PVC) d≤8 8<d≤12 12<d≤20 d>20
Fixed installation 3 D 3 D 4 D 4 D
Free movement 5 D 5 D 6 D 6 D
At inlet of portable appliance or mobile equipment a 5 D 5 D 6 D 6 D
Under mechanical load b 9 D 9 D 9 D 10 D
Festooned c 10 D 10 D 11 D 12 D
Repeated reeling b 7 D 7 D 8 D 8 D
Deflected by pulleys b 10 D 10 D 10 D 10 D
D = the overall diameter of round cables or the smaller dimension of flat cables.
a No mechanical load on the cable
b See 5.6.2 of IEC 62440 with regard to dynamic stess.
c As in gantry cranes.

Table 3 – Technical Specifications

Cable type Rated voltage Strands No./Dia. Of Conductor Insulation Thickness Approx. O.D. Approx.
Weight
Max. D.C Resistance of Conductor (20 ℃) Testing Voltage A.C Current Rating
In Air(A) /30℃
/ V pc/mm mm (mm) kg/km Ω /km kV/5min single double triple
60227 IEC 06 (RV) 300/500V 1×0.5 300/500 1/16/0.20 0.6 2.2 9 39 2000 12 6 4
60227 IEC 06 (RV) 300/500V 1×0.75 300/500 1/24/0.20 0.6 2.4 12 26 2000 14 8 5
60227 IEC 06 (RV) 300/500V 1×1 300/500 1/30/0.20 0.6 2.6 14 19.5 2000 17 9 7
60227 IEC 02 (RV) 450/750V 1×1.5 450/750 1/30/0.25 0.7 3.1 20 13.3 2500 22 11 8
60227 IEC 02 (RV) 450/750V 1×2.5 450/750 1/49/0.25 0.8 3.7 31 7.98 2500 29 13 10
60227 IEC 02 (RV) 450/750V 1×4 450/750 1/53/0.30 0.8 4.3 46 4.95 2500 40 17 11
60227 IEC 02 (RV) 450/750V 1×6 450/750 7/12/0.30 0.8 5.3 68 3.3 2500 51 24 18
60227 IEC 02 (RV) 450/750V 1×10 450/750 7/11/0.40 1 6.7 113 1.91 2500 74
60227 IEC 02 (RV) 450/750V 1×16 450/750 7/17/0.40 1 7.9 166 1.21 2500 100
60227 IEC 02 (RV) 450/750V 1×25 450/750 7/26/0.40 1.2 9.9 254 0.78 2500 135
60227 IEC 02 (RV) 450/750V 1×35 450/750 7/36/0.40 1.2 11.2 342 0.554 2500 165
60227 IEC 02 (RV) 450/750V 1×50 450/750 19/19/0.40 1.4 13.4 488 0.386 2500 215
60227 IEC 02 (RV) 450/750V 1×70 450/750 19/17/0.50 1.4 15.3 680 0.272 2500 260
60227 IEC 02 (RV) 450/750V 1×95 450/750 19/23/0.50 1.6 17.6 891 0.206 2500 300-
60227 IEC 02 (RV) 450/750V 1×120 450/750 19/30/0.50 1.6 19.3 1,129 0.161 2500 350-
60227 IEC 02 (RV) 450/750V 1×150 450/750 37/19/0.50 1.8 21.5 1,402 0.129 2500 400-
60227 IEC 02 (RV) 450/750V 1×185 450/750 37/25/0.49 2 24.1 1,740 0.106 2500 450-
60227 IEC 02 (RV) 450/750V 1×240 450/750 37/33/0.49 2.2 27.4 2,285 0.0801 2500 550-

Ordering Advice

Rated Voltage

Application Standard: IEC/BS/UL/GB

Number of Cores

Conductor Size & Construction

Type of Insulation

The Requirement of Sheath

Length of Cable & Packing Requirement

Other Requirement

PACKING AND SHIPPING

We are capable of meeting the strictest delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.

Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self-adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.

We are China Indoor PVC Insulated Flexible Cable Compact Stranded Copper Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , ,