Indoor Embedded 12KV Vacuum AC Circuit Breaker
Indoor Embedded 12KV Vacuum AC Circuit Breaker image
Brand Name :
Suntech
Model Number :
VF(R)-12
Certification :
ISO
Place of Origin :
Ningbo,China
MOQ :
1 PCS
Price :
Get newest price
Payment Terms :
L/C , T/T, Western Union
Supply Ability :
20000 pcs per month
Delivery Time :
30 days after Payment
Packaging Details :
Exported cartons or cases
Type :
Vacuum Circuit Breaker
Poles Number :
3
Ambient temperature :
-40°C-+40°C
Altitude :
≤1000m
New Generation Indoor Embedded High Voltage Vacuum AC Circuit Breaker
VF(R)-12 indoor embedded high-voltage alternating-current vacuum load switch-fuse combination (“vacuum load switch" )is a new generation vacuum switching equipment developed based on unique design ideas to meet the market demand. It is widely used for indoor armored air-insulated switch cabinets. In normal conditions, it can operate within its technical parameters in any grid of the specified voltage level safely and stably.
Item | Unit | Reference value | ||||
VF-12/T630-20 Vacuum load switch |
VFR-12/T125-50 Vacuum load switch-fuse combination |
VFH-12/T630-25 High breaking capacity vacuum switch |
VFHR-12/T125-50 High breaking capacity vacuum switch-fuse combination |
|||
Rated voltage | kV | 12 | 12 | 12 | 12 | |
Rated insulation level | Lightning impuse withstand voltage | kV | 75 | 75 | 75 | 75 |
1min power-frequency withstand voltage | kV | 42 | 42 | 42 | 42 | |
Rated frequency | Hz | 50/60 | 50/60 | 50/60 | 50/60 | |
Rated current | A | 630 | 125(fuse) | 630 | 125(fuse) | |
Rated short-circuit breaking current |
kA | – | 50(fuse) | 25 | 25 | |
Rated short- circuit making current (peak value) |
kA | 50 | – | 63 | – | |
Rated short-time withstand current |
kA | 20 | – | 25 | – | |
Rated withstand current (peak value) |
kA | 50 | – | 63 | – | |
Rated breaking current of cable during charge |
A | 16 | – | – | – | |
Rated breaking current of no-load transformer |
kVA | 1250 | – | 1250 | – | |
Rated breaking take-over current |
A | – | 3150 | – | 3150 | |
Breaking times of the rated short-circuit current |
Times | |||||
Mechanical life | M2 level | M2 level | M2 level | M2 level | ||
Weight | kg | 125 |
ransformer capacity and fuse selection
1. The fuse can cut off a large short-circuit current in less than 10 ms and its breaking current can be up to 50KA. Thus, it can protect the transformer most efectively.
2. In terms of match between the transformer and the fuse (Table 1), the potential surge current of the fuse must be considered. Thus, fusing current of the fuse must be 1.6 times of the rated value; designer must consider possible fluctuations of other parameters of the grid and reserve margins for them. If a fuse is selected for high-voltage motor protection, designer must consider frequency of start of the high-voltage motor because frequent starts of the high-voltage motor will result in the fuse's failure when timely cooling is not available.
Primary voltage of the transformer(kV) |
Capacity of the transformer(kVA) |
Model of the fuse |
Rated current of the fuse(A) |
|
Model for the domestic market |
Model for international market |
|||
6.6 | 200 | XRNT-10 | 12kV BDGHC | 31.5 |
250 | 40 | |||
300/315 | 50 | |||
400 | 12kV BDGHC | 63 | ||
500 | 80 | |||
630 | 90 |
Standard |
1. GB 3804-2004 High-voltage load alternating-current switches for rated voltage above 3.6 kV and less than 40.5 kV 2. GB 16926-2009 High-voltage load alternating- current switch-fuse combinations
|
Operating conditions |
1. Ambient temperature: – 40℃-+40℃ (below 35℃ within 24 hours) 2. Relative humidity:≤95% (daily average) or≤90% (monthly average) 3. Altitude: ≤1000m |
We are China Indoor Embedded 12KV Vacuum AC Circuit Breaker manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: 12KV AC Circuit Breaker, Indoor Embedded AC Circuit Breaker, Indoor Embedded Vacuum Circuit Breaker, Vacuum Circuit Breaker