IEC 60502-1 0.6/1 KV PVC Insulated Power Cable Copper Conductor Class 2 PVC Insulated And Sheathed From 1 To 5 Core

 China IEC 60502-1 0.6/1 KV PVC Insulated Power Cable Copper Conductor Class 2 PVC Insulated And Sheathed From 1 To 5 Core supplier

IEC 60502-1 0.6/1 KV PVC Insulated Power Cable Copper Conductor Class 2 PVC Insulated And Sheathed From 1 To 5 Core image

Get a Quote Email to us

Brand Name :
Chengtiantai Cable

Model Number :
NYY

Certification :
CE, CB

Place of Origin :
Shenzhen, Mainland China

MOQ :
Negotiable

Price :
Negotiable

Payment Terms :
L/C, T/T

Delivery Time :
15 working days after payments

Packaging Details :
Steel Wooden Drum

Nominal Voltage :
0.6/1 kV

Core Insulation :
PVC

No. of Conductor :
from 1 to 5

Outer Sheath :
PVC

Conductor Material :
Bare Copper Class 2

Manufacturer :
Shenzhen Chengtiantai

PVC Insulated Power Cable

Copper Conductor, PVC Insulated & Sheathed

APPLICATIONS:

IEC 60502-1 PVC Insulated Power cables for energy supply are installed in open air, in underground, indoors, in cable ducts, power stations, residental connections and street lighting as well as in subscriber networks, where mechanical damages are not be expected.

STANDARDS

International: IEC 60502-1
National:GB/ T 12706.1-2008

CONSTRUCTION OF PVC INSULATED POWER CABLE:

1. CONDUCTOR– Bare copper conductor, Class 2 to IEC 60228

2. INSULATION
– PVC Compound
3. FILLER

– PP filler

4. INNER SHEATH(in case of armoured cable)

– PVC Compound

5. ARMOUR

– Two steel tape

6. OUTER SHEATH :
– PVC Compound

Sheath colour :
– Black

*Note: when required for a particular application, other colors are available.

Electrical Characteristics OF PVC Insulated power cable

Rated Voltage Uo/U

0.6/1 kV

Maximum operating voltage

1.2 kV

Frequence

50 Hz

Test voltage :

3500 V

Usage Characteristics of IEC 60502-1 PVC power cable

Permissible operating temperature at conductor

70°C

short circuit temperature ( duration max. 5 s)

160 °C

Minimum installation temperature

should not be lower than 0°C

Max. conductor permissible tensile stress

50 N/mm²

Minimum bending radius

12 x cable Ø

Physical and Electrical Characteristics:

Single Core PVC Insulted Power Cable (Unarmored)

No.cores x
cross-sec.

Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.

weight
approx.

Current ratings in air 30℃

Current ratings buried 20℃

maximum DC resistance at 20℃

mm²

mm

mm

mm

kg / km

A

A

Ω/km

1×1.5

0.8

1.4

6.1

61

24

29

12.1

1×2.5

0.8

1.4

6.5

74

31

38

7.41

1×4.0

1.0

1.4

7.4

100

41

49

4.61

1×6.0

1.0

1.4

7.9

124

52

61

3.08

1×10

1.0

1.4

9.2

183

72

83

1.83

1×16

1.0

1.4

10.3

251

95

105

1.15

1×25

1.2

1.4

12.0

367

120

135

0.73

1×35

1.2

1.4

13.1

475

150

160

0.52

1×50

1.4

1.4

14.9

618

180

195

0.39

1×70

1.4

1.4

16.9

840

230

240

0.27

1×95

1.6

1.5

19.3

1134

280

285

0.19

1×120

1.6

1.5

21.1

1384

325

325

0.15

1×150

1.8

1.6

23.1

1683

375

365

0.12

1×185

2.0

1.7

25.6

2084

430

415

0.10

1×240

2.2

1.8

28.9

2696

510

480

0.08

1×300

2.4

1.9

31.7

3355

585

545

0.06

1×400

2.6

2.0

33.0

4246

690

625

0.05

1×500

2.8

2.1

37.2

5092

800

710

0.04

1×630

2.8

2.2

40.5

6362

920

810

0.03

2 Core PVC Insulted Power Cable (Unarmored)

No.cores x
cross-sec.

Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.

weight
approx.

Current ratings in air 30℃

Current ratings buried 20℃

maximum DC resistance at 20℃

mm²

mm

mm

mm

kg / km

A

A

Ω/km

2×1.5

0.8

1.8

10.5

129

19

25

12.1

2×2.5

0.8

1.8

11.3

158

26

34

7.41

2×4.0

1.0

1.8

13.0

221

35

44

4.61

2×6.0

1.0

1.8

14.0

274

44

56

3.08

2×10

1.0

1.8

16.7

378

60

76

1.83

2×16

1.0

1.8

18.8

519

80

100

1.15

2×25

1.2

1.8

22.6

758

107

129

0.73

2×35

1.2

1.8

19.2

978

131

157

0.52

2×50

1.4

1.8

22.0

1217

152

187

0.39

2×70

1.4

1.9

24.3

1613

194

233

0.27

2×95

1.6

2.0

27.0

2157

238

278

0.19

2×120

1.6

2.1

30.0

2658

275

318

0.15

2×150

1.8

2.2

33.0

3296

318

357

0.12

2×185

2.0

2.4

36.8

4027

366

404

0.10

2 Core PVC Insulted Power Cable (armored)

No.cores x
cross-sec.

Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.

weight
approx.

Current ratings in air 30℃

Current ratings buried 20℃

maximum DC resistance at 20℃

mm²

mm

mm

mm

kg / km

A

A

Ω/km

2×4

1.0

1.8

16.3

388

34

44

4.61

2×6

1.0

1.8

17.3

454

43

53

3.08

2×10

1.0

1.8

20.0

589

58

70

1.83

2×16

1.0

1.8

22.0

748

77

92

1.15

2×25

1.2

1.8

25.5

1029

104

122

0.73

2×35

1.2

1.8

27.8

1276

129

149

0.52

2×50

1.4

1.8

26.5

1487

146

171

0.39

2×70

1.4

1.9

30.3

2178

188

214

0.27

2×95

1.6

2.1

34.2

2800

240

267

0.19

2×120

1.6

2.2

36.5

3365

274

306

0.15

2×150

1.8

2.4

40.0

4059

316

346

0.12

2×185

2.0

2.5

43.8

4984

368

394

0.10

3 Core PVC Insulted Power Cable (Unarmored)

No.cores x
cross-sec.

Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.

weight
approx.

Current ratings in air 30℃

Current ratings buried 20℃

maximum DC resistance at 20℃

mm²

mm

mm

mm

kg / km

A

A

Ω/km

3×1.5

0.8

1.8

11

154

17

22

12.1

3×2.5

0.8

1.8

11.9

194

22

29

7.41

3×4.0

1.0

1.8

13.8

274

29

38

4.61

3×6.0

1.0

1.8

14.9

348

37

47

3.08

3×10

1.0

1.8

17.6

529

52

65

1.83

3×16

1.0

1.8

19.9

740

68

85

1.15

3×25

1.2

1.8

23.7

1058

91

110

0.73

3×35

1.2

1.8

26.1

1382

112

134

0.52

3×50

1.4

1.8

26.4

1760

133

159

0.39

3×70

1.4

2.0

29.8

2364

171

199

0.27

3×95

1.6

2.1

33.8

3158

209

237

0.19

3×120

1.6

2.2

36.7

3921

242

271

0.15

3×150

1.8

2.3

40.2

4868

282

305

0.12

3×185

2.0

2.5

45.6

5952

329

346

0.10

3×240

2.2

2.7

51.7

7713

392

400

0.08

3×300

2.4

2.9

56.1

10004

450

462

0.06

3 Core PVC Insulted Power Cable (armored)

No.cores x
cross-sec.

Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.

weight
approx.

Current ratings in air 30℃

Current ratings buried 20℃

maximum DC resistance at 20℃

mm²

mm

mm

mm

kg / km

A

A

Ω/km

3×4

1.0

1.8

17.0

450

29

36

4.61

3×6

1.0

1.8

18.1

538

37

45

3.08

3×10

1.0

1.8

20.8

745

50

60

1.83

3×16

1.0

1.8

23.1

983

66

79

1.15

3×25

1.2

1.8

26.9

1344

90

105

0.73

3×35

1.2

1.8

29.3

1702

111

127

0.52

3×50

1.4

1.9

31.2

2344

129

148

0.39

3×70

1.4

2.0

34.4

3017

165

185

0.27

3×95

1.6

2.2

38.6

3913

206

221

0.19

3×120

1.6

2.3

41.7

4741

242

261

0.15

3×150

1.8

2.5

45.5

5790

281

296

0.12

3×185

2.0

2.6

51.0

7013

328

337

0.10

3×240

2.2

2.8

57.3

8930

386

389

0.08

3×300

2.4

3.0

61.5

11350

445

441

0.06

4 Core PVC Insulted Power Cable (Unarmored)

No.cores x
cross-sec.

Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.

weight
approx.

Current ratings in air 30℃

Current ratings buried 20℃

maximum DC resistance at 20℃

mm²

mm

mm

mm

kg / km

A

A

Ω/km

4×4

1.0

1.8

14.9

339

30

38

4.61

4×6

1.0

1.8

16.1

436

38

48

3.08

4×10

1.0

1.8

19.3

669

53

66

1.83

4×16

1.0

1.8

21.8

953

70

86

1.15

4×25

1.2

1.8

26.0

1374

94

112

0.73

4×35

1.2

1.8

28.7

1810

116

135

0.52

4×50

1.4

1.9

29.5

2312

139

161

0.39

4×70

1.4

2.1

33.0

3105

177

202

0.27

4×95

1.6

2.2

38.1

4179

217

240

0.19

4×120

1.6

2.4

41.1

5185

254

274

0.15

4×150

1.8

2.5

45.8

6414

294

309

0.12

4×185

2.0

2.7

50.5

7901

337

346

0.10

4×240

2.2

2.9

55.7

10249

401

403

0.08

4×300

2.4

3.1

63.4

13365

470

459

0.06

4 core PVC Insulated power cable (Armored)

No.cores x
cross-sec.

Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.

weight
approx.

Current ratings in air 30℃

Current ratings buried 20℃

maximum DC resistance at 20℃

mm²

mm

mm

mm

kg / km

A

A

Ω/km

4×4

1.0

1.8

18.2

529

30

37

4.61

4×6

1.0

1.8

19.3

641

38

46

3.08

4×10

1.0

1.8

22.5

905

53

64

1.83

4×16

1.0

1.8

25.0

1218

71

83

1.15

4×25

1.2

1.8

29.2

1690

94

108

0.73

4×35

1.2

1.9

33.5

2479

117

132

0.52

4×50

1.4

2.0

34.3

2963

140

157

0.39

4×70

1.4

2.2

37.8

3831

178

196

0.27

4×95

1.6

2.4

43.1

5032

219

234

0.19

4×120

1.6

2.5

46.3

6105

255

268

0.15

4×150

1.8

2.6

51.0

7475

294

301

0.12

4×185

2.0

2.8

56.2

9070

333

338

0.10

4×240

2.2

3.0

61.3

11664

397

393

0.08

4×300

2.4

3.2

69.3

15018

464

448

0.06

5 Core PVC Insulted Power Cable (Unarmored)

No.cores x
cross-sec.

Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.

weight
approx.

Current ratings in air 30℃

Current ratings buried 20℃

maximum DC resistance at 20℃

mm²

mm

mm

mm

kg / km

A

A

Ω/km

5×4

1.0

1.8

16.2

403

31

39

4.61

5×6

1.0

1.8

17.5

520

39

49

3.08

5×10

1.0

1.8

21.0

811

54

67

1.83

5×16

1.0

1.8

23.8

1156

72

87

1.15

5×25

1.2

1.8

28.5

1778

96

111

0.73

5×35

1.2

1.9

31.3

2348

118

134

0.52

5×50

1.4

2.1

37.0

3129

144

159

0.39

5×70

1.4

2.2

42.0

4357

186

199

0.27

5×95

1.6

2.4

49.1

5953

227

235

0.19

5×120

1.6

2.5

53.6

7298

266

269

0.15

5×150

1.8

2.7

59.3

8947

303

302

0.12

5×185

2.0

2.9

66.0

11144

352

343

0.10

5×240

2.2

3.1

74.6

14327

420

398

0.08

5×300

2.4

3.3

82.6

17823

483

452

0.06

5 Core PVC Insulted Power Cable (armored)

No.cores x
cross-sec.

Insulation
thickness

Inner Sheath thickness

Nominal

Sheath
thickness

Outer Ø
approx.

weight
approx.

Current ratings in air 30℃

Current ratings buried 20℃

maximum DC resistance at 20℃

mm²

mm

mm

mm

mm

kg / km

A

A

Ω/km

5×4

1.0

0.9

1.8

19.4

606

31

38

4.61

5×6

1.0

0.9

1.8

20.7

739

39

47

3.08

5×10

1.0

0.9

1.8

24.2

1072

55

65

1.83

5×16

1.0

0.9

1.8

27.0

1450

72

85

1.15

5×25

1.2

0.9

1.8

31.9

2143

96

108

0.73

5×35

1.2

0.9

2.0

36.4

3098

119

131

0.52

5×50

1.4

1.2

2.2

41.6

3992

145

156

0.39

5×70

1.4

1.2

2.3

46.8

5356

187

195

0.27

5×95

1.6

1.2

2.5

54.1

7138

225

230

0.19

5×120

1.6

1.4

2.6

58.8

8616

263

274

0.15

5×150

1.8

1.4

2.8

64.7

10429

296

301

0.12

5×185

2.0

1.4

3.0

76.6

12817

335

348

0.10

5×240

2.2

1.4

3.2

80.8

15226

387

409

0.08

5×300

2.4

1.4

3.5

89.0

20062

439

472

0.06

3 +2 Core PVC Insulated Power Cable (Unarmored)

No.cores x cross-sec.

Insulation thickness

Sheath thickness Nominal value

Outer Ø approx.

weight approx.

Current ratings in air 30℃

Current ratings buried 20℃

Phase

Neutral

mm²

mm

mm

mm

mm

kg / km

A

A

3×4+2×2.5

1.0

0.8

1.8

15.3

351

30

38

3×6+2×4.0

1.0

1.0

1.8

17.0

473

38

48

3×10+2×6.0

1.0

1.0

1.8

19.7

691

52

66

3×16+2×10

1.0

1.0

1.8

22.0

1012

69

86

3×25+2×16

1.2

1.0

1.8

26.8

1536

93

111

3×35+2×16

1.2

1.0

1.8

28.9

1872

113

134

3×50+2×25

1.4

1.2

1.9

34.2

2596

141

163

3×70+2×35

1.4

1.2

2.0

38.8

3524

180

203

3×95+2×50

1.6

1.4

2.2

44.4

4776

221

242

3×120+2×70

1.6

1.4

2.3

49.0

6124

258

276

3×150+2×70

1.8

1.4

2.4

53.7

7113

298

310

3×185+2×95

2.0

1.6

2.6

60.0

9046

343

349

3×240+2×120

2.2

1.6

2.8

67.5

11558

408

406

3×300+2×150

2.4

1.8

3.0

75.0

14389

479

462

3 +2 Core STEEL TAPE ARMOURED POWER CABLE

No.cores x cross-sec.

Insulation thickness

Sheath thickness Nominal value

Outer Ø approx.

weight approx.

Current ratings in air 30℃

Current ratings buried 20℃

Phase

Neutral

mm²

mm

mm

mm

mm

kg / km

A

A

3×4+2×2.5

1.0

0.8

1.8

18.5

495

30

37

3×6+2×4.0

1.0

1.0

1.8

20.2

608

38

46

3×10+2×6.0

1.0

1.0

1.8

22.9

834

52

64

3×16+2×10

1.0

1.0

1.8

26.0

1143

70

84

3×25+2×16

1.2

1.0

1.8

30.2

1607

93

108

3×35+2×16

1.2

1.0

1.8

33.5

2060

113

130

3×50+2×25

1.4

1.2

1.9

38.8

2795

142

158

3×70+1×35

1.4

1.2

2.1

43.6

3581

181

199

3×95+2×50

1.6

1.4

2.3

49.4

4676

222

236

3×120+2×70

1.6

1.4

2.4

55.0

5751

258

269

3×150+2×70

1.8

1.4

2.5

59.1

6788

297

303

3×185+2×95

2.0

1.6

2.7

65.6

8371

338

340

3×240+2×120

2.2

1.6

2.9

73.7

10523

404

396

3×300+2×150

2.4

1.8

3.1

81.5

13572

472

450

*Dimensions and specifications may be changed without prior notice.

Conductor Design

Packaging & Delivery

Packaging details :

Delivery :

Steel Wooden Drums

Cable Drum In container

shipped in 15 days after payment

Cable Drum Data

CABLE DRUMS

D1=Flange Diameter(mm)

W=Useful Width (mm)

D2=Barrel Diameter(mm)

1000

700

500

1100

700

550

1200

700

600

1400

750

710

1600

900

900

1800

1120

1000

2400

1150

1300

Delivery Port:

Port of Shenzhen

Port of Hongkong

Port of Guangzhou

Manufacturing Process Of Low Voltage Power Cable ( Unarmored )

1. copper rod

2. wire drawing

3. wire stranding

4.Inner sheath

5. Assembling

6.outer covering Process

7. Sheath Marking

8. Packing

9. cable delivering

Our production in numbers

● Cable production started 1983
● 35 years of cable manufacturing experience

● Sales in 2016 about 500 million USD

● 100,000 m2 Production area
● 350 Will-trained employees
● Exported more than 22 countries
● 2 Manufacturing plant
● 1 R&D Center

● 200 Sets Of Testing Equipment

● 100 Testing Items
● 8 workshop
● 40 wire drawing machines
● 10 bunching machines
● 28 Extruder system
● 42 stranding machines
● 10 Braiding machines

Some great shots of our manufactering plant

Mannufacturing plant

R&D Building

Bird's eye view of the plant

MV Power Cable Workshop

Cable Reels Waiting to be shipped out

Shipping

Shenzhen chengtiantai cable operates certified management systems compliant with:

Certificat

Information

ISO 9001

quality management systems

Certificat ISO 9001:2008
– Shenzhen chengtiantai cable industry development Co.Ltd. ;
Certified through Guangdong quality Testing CTC Certification Co.Ltd.;
Valid until 09 January 2022

ISO 14001

environmental management systems

Certificat ISO 14001:2004

– Shenzhen chengtiantai cable industry development Co.Ltd. ;

Certified through Guangdong quality Testing CTC Certification Co.Ltd.;

Valid until 09 January 2022

OHSAS 18001

assessment specification for occupational health & safety management systemsenvironmental management systems

Certificat OHSAS 18001:2007

– Shenzhen chengtiantai cable industry development Co.Ltd. ;

Certified through Guangdong quality Testing CTC Certification Co.Ltd.;

Valid until 09 January 2022

Customer services:

RECOMMENDED ORDERING PARAMETERS

CONTACT

For prompt quotation / supplies please make sure your inquiries and your orders are
securing the following data :

1 – International or Special Standard. (Alternatively, the precise usage of the cable.)
2 – Rated voltage.
3 – Copper or Aluminium conductors.
4 – Size of each conductor.
5 – Insulation material : XLPE or others.
6 – Number and identification of conductors.
7 – Other requirements.
8 – Packing.
9 – Required delivery time.
10 – Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.

We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

Tel:+86 755 6114 5028
Fax:+86 755 61137976
E-mail : [email protected]
Head office:chengtiantai Industrial Park, Lisonglang community, Gongming office, Guangming district, Shenzhen P.R. China 518106

WARRANTY

For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

We are China IEC 60502-1 0.6/1 KV PVC Insulated Power Cable Copper Conductor Class 2 PVC Insulated And Sheathed From 1 To 5 Core manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION