Galvanized steel wire strand
Galvanized steel wire strand image
Place of Origin :
Anhui,China
Brand Name :
Litong Global
Certification :
ISO9001 and other 3rd party Inspection report
Model Number :
L5-151222
Steel Grade :
Middle and High Carbon Wire Rod
Wire Gauge :
1.0-4.8mm
Standard :
AISI|ASTM|BS|DIN|GB|JIS
Type :
Galvanized
Alloy Or Not :
Non-alloy
Special Use :
Free Cutting Steel
MOQ :
Negotiable
Price :
Negotiable
Packaging Details :
In Coil or on Drum
Delivery Time :
10 days after confirmed order
Payment Terms :
TT/LC
Supply Ability :
400tons/day
Application :
guy wire,stay wire,ACSR Conductor,rope etc.
Description
Our galvanized stranded wires provide a combination of superior properties compared to conventional six strand ropes. With compacted structure and smooth face, this 1*7 galvanized stranded wire provides enhanced durability and resistance to abrasion and crushing, and improves the service life.
Construction & Diameter: 1*7/4.8-12.7 mm
Features
1. The galvanized stranded wire offers a smooth and polished surface.
2. It offers excellent antirust performance.
3. It is adhesive and flexible.
Application
Our 1*7 galvanized stranded wire can be used as messenger wires, guy wires, core wires or strength members, earth wires/ground wires, barrier cables, structure cables, messenger wires for optical fiber cable, etc.
As a professional 1*7 galvanized stranded wire manufacturer and supplier based in China, We also offers1*3, 1*19 galvanized stranded wire, 12.70mm PC strand, 2.0mm and 2.64mm galvanized steel wire, among others.
EN 50189 Standard
12
Table 1. Initial Settings for Determining Stress 1% Extension |
|||
Nominal Wire Diameter, mm |
Initial Stress, N/mm2 |
Initial setting of extensometer for a gauge length of 250mm2 |
|
1.24 |
2.25 |
100 |
0.125 |
2.25 |
3 |
200 |
0.25 |
3 |
4.75 |
300 |
0.375 |
4.75 |
5.5 |
400 |
0.5 |
For other gauge lengths, multiply the initial setting by the gauge length in mm divided by 250. |
Table 2. Zinc Coating Requirements |
|||||||||||
Nominal Wire Diameter, mm |
Class A |
Class B |
Class C |
Class D |
Class E |
||||||
Over |
Up to and incl. |
Min. mass of Zn g/m2 |
Min. no. of one minute dips |
Min. mass of Zn g/m2 |
Min. no. of one minute dips |
Min. mass of Zn g/m2 |
Min. no. of one minute dips |
Min. mass of Zn g/m2 |
Min. no. of one minute dips |
Min. mass of Zn g/m2 |
Min. no. of one minute dips |
1.24 |
1.5 |
185 |
2 |
370 |
3.5 |
150 |
1 |
365 |
3 |
185 |
2 |
1.5 |
1.75 |
200 |
2 |
400 |
3.5 |
160 |
1.5 |
460 |
3.5 |
200 |
2 |
1.75 |
2 |
215 |
2.5 |
430 |
4 |
175 |
2 |
550 |
4 |
215 |
2.5 |
2 |
2.25 |
215 |
2.5 |
430 |
4 |
175 |
2 |
550 |
4 |
250 |
3.5 |
2.25 |
2.75 |
230 |
3 |
460 |
4 |
190 |
2.5 |
640 |
5 |
250 |
3.5 |
2.75 |
3 |
230 |
3 |
460 |
4 |
190 |
2.5 |
640 |
5 |
250 |
3.5 |
3 |
3.5 |
245 |
3.5 |
490 |
4 |
205 |
3 |
730 |
6 |
250 |
3.5 |
3.5 |
4.25 |
260 |
3.5 |
520 |
4 |
260 |
3.5 |
730 |
6 |
260 |
3.5 |
4.25 |
4.75 |
275 |
4 |
550 |
4 |
275 |
4 |
775 |
6 |
275 |
4 |
4.75 |
5 |
200 |
4 |
580 |
5 |
290 |
4 |
825 |
6 |
290 |
4 |
5 |
5.25 |
290 |
4 |
580 |
5 |
290 |
4 |
825 |
6 |
290 |
4 |
5.25 |
5.5 |
290 |
4 |
580 |
5 |
290 |
4 |
825 |
6 |
290 |
4 |
Table 3. Mechanical Properties of ST1A Wires |
|||||||
Nominal wire diameter mm |
Diameter tolerance |
Stress at 1% extension, MPa |
Tensile strength, MPa |
Elongation on 250mm |
Mandrel diameter for wrapping test |
No. of torsion twists |
|
Over |
Up to and incl. |
mm |
N/MM2 |
N/MM2 |
% |
||
Min. |
Min. |
Min. |
xd |
Min. |
|||
1.24 |
1.5 |
±0.03 |
1170 |
1400 |
3 |
1 |
18 |
1.5 |
1.75 |
±0.03 |
1170 |
1400 |
3 |
1 |
18 |
1.75 |
2.25 |
±0.03 |
1170 |
1400 |
3 |
1 |
18 |
2.25 |
2.75 |
±0.04 |
1140 |
1350 |
3 |
1 |
16 |
2.75 |
3 |
±0.05 |
1140 |
1350 |
3.5 |
1 |
16 |
3 |
3.5 |
±0.05 |
1100 |
1300 |
3.5 |
1 |
14 |
3.5 |
4.25 |
±0.06 |
1100 |
1300 |
4 |
1 |
12 |
4.25 |
4.75 |
±0.06 |
1100 |
1300 |
4 |
1 |
12 |
4.75 |
5.5 |
±0.07 |
1100 |
1300 |
4 |
1 |
12 |
Table 4. Mechanical properties of ST2B Wires |
||||||
Nominal wire diameter mm |
Diameter tolerance |
Stress at 1% extension, MPa |
Tensile strength, MPa |
Elongation on 250mm |
Mandrel diameter for wrapping test |
|
Over |
Up to and incl. |
mm |
N/MM2 |
N/MM2 |
||
1.24 |
1.5 |
±0.05 |
1100 |
1300 |
4 |
1 |
1.5 |
1.75 |
±0.05 |
1100 |
1300 |
4 |
1 |
1.75 |
2.25 |
±0.05 |
1100 |
1300 |
4 |
1 |
2.25 |
2.75 |
±0.06 |
1070 |
1250 |
4 |
1 |
2.75 |
3 |
±0.06 |
1070 |
1250 |
4 |
1 |
3 |
3.5 |
±0.07 |
1000 |
1200 |
4 |
1 |
3.5 |
4.25 |
±0.09 |
1000 |
1200 |
4 |
1 |
4.25 |
4.75 |
±0.10 |
1000 |
1200 |
4 |
1 |
4.75 |
5.5 |
±0.11 |
1000 |
1200 |
4 |
1 |
Other Products
BS4565-1990 Standard
Home » Products » Standards » BS4565-1990
Table 1. Initial Settings for Determining Stress 1% Extension |
|||
Nominal Diameter of Galvanized Steel Wire |
Initial Stress N/mm2 |
Initial Setting of Extensometer mm/mm |
|
> |
< |
||
mm |
mm |
||
1.18 |
2.24 |
95 |
0.05 |
2.24 |
3.15 |
190 |
0.10 |
3.15 |
5.00 |
285 |
0.15 |
Table 2. Tensile Strength and Stress at 1% Elongation |
|||
Nominal Diameter of Galvanized Steel Wire |
Tensile Strength minimum N/mm2 |
Stress at 1% elongation minimum N/mm2 |
|
> |
< |
||
mm |
mm |
||
1.18 |
2.24 |
1400 |
1180 |
2.24 |
3.15 |
1320 |
1140 |
3.15 |
5.00 |
1320 |
1100 |
Table 3. Properties for High Strength Galvanized Steel Wire for ACSR |
||||||||||
Tensile strength grade N/mm2, min. |
1550 |
1700 |
1800 |
|||||||
Nominal diameter of galvanized wire |
Min. stress at 1% elongation |
Min. elongation L0+=200mm% |
Steel wrap test dia. |
Min. stress at 1% elongation |
Min. elongation L0+=200mm% |
Steel Wrap test dia. |
Min. stress at 1% elongation |
Min. elongation L0+=200mm% |
Steel wrap test dia. |
|
> |
≤ |
|||||||||
mm |
mm |
|||||||||
1.18 |
1.32 |
1260 |
3.0 |
1d |
1320 |
3.0 |
2d |
1370 |
3.0 |
3d |
1.32 |
1.80 |
1260 |
3.5 |
1d |
1320 |
3.0 |
2d |
1370 |
3.0 |
3d |
1.80 |
2.24 |
1260 |
3.5 |
2d |
1320 |
3.0 |
2d |
1370 |
3.0 |
3d |
2.24 |
2.72 |
1260 |
3.5 |
2d |
1320 |
3.5 |
3d |
1370 |
3.0 |
3d |
2.72 |
2.90 |
1260 |
3.5 |
2d |
1320 |
3.5 |
3d |
1370 |
3.0 |
3d |
2.90 |
4.00 |
1220 |
4.0 |
3d |
1280 |
3.5 |
3d |
– |
– |
– |
4.00 |
5.00 |
1220 |
4.0 |
3d |
– |
– |
– |
– |
– |
– |
d=Nominal diameter of galvanized wire |
||||||||||
L0= Original Gauge Length |
Table 4. Conversions of Tensile Strength and Stress at 1% Elongation |
|
N/MM2 |
tonf/in2 |
1100 |
71.2 |
1140 |
73.8 |
1180 |
76.4 |
1220 |
79.0 |
1260 |
81.6 |
1280 |
82.9 |
1320 |
85.5 |
1370 |
88.7 |
1400 |
9.07 |
1550 |
100.4 |
1700 |
110.1 |
1800 |
116.6 |
ASTMB498B/498M-2002 Standard
Home » Products » Standards » ASTMB498B 498M-2002
Table 1. Zinc Coating |
|||
Specified Diameter of Coated Wre |
Class A |
|
Class C |
1.6-1.9 |
210 |
|
630 |
>1.9-2.3 |
220 |
440 |
660 |
>2.3-2.7 |
230 |
460 |
690 |
>2.7-3.1 |
240 |
480 |
720 |
>3.1-3.5 |
260 |
520 |
780 |
>3.5-3.9 |
270 |
540 |
810 |
>3.9-4.5 |
275 |
550 |
825 |
>4.5-4.8 |
300 |
600 |
900 |
Table 2. Tensile Requirements |
|||||||||
Specified Diameter |
Stress at 1 % Extension min Mpa |
Ultimate Tensile Strength min MPA |
Elongation in 250mm, min, 1% |
||||||
Class A |
Class B |
Class C |
Class A |
Class B |
Class C |
Class A |
Class B |
Class C |
|
1.6-2.3 |
1310 |
1240 |
1170 |
1450 |
1380 |
1310 |
3 |
3 |
3 |
>2.3-3.05 |
1280 |
1210 |
1140 |
1410 |
1340 |
1280 |
3.5 |
3 |
3 |
>3.05-3.6 |
1240 |
1170 |
1100 |
1410 |
1340 |
1280 |
4 |
3 |
3 |
>3.6-4.8 |
1170 |
1100 |
1070 |
1380 |
1280 |
1240 |
4 |
4 |
4 |
Table 3. Initial Settings for Determining Stress 1% Extension |
||
Specified Diameter, mm |
Initial Stress, MPA |
Initial Setting of Extensometer, mm/mm |
1.6-2.3 |
100 |
0.0005(0.05% extension) |
>2.3-3.05 |
190 |
0.0010(0.10% extension) |
>3.05-4.8 |
290 |
0.0015(0.15% extension) |
Table 4. Mandrel Size for Adherence Test |
|
Specified Wire Diameter,mm |
Ratio of Mandrel Diameter to Wire Diameter |
1.6-2.3 |
3 |
>2.3-3.05 |
4 |
>3.05-4.8 |
5 |
Table 5. Permissible Variations in Diameter of Zinc-Coated Steel Wire |
||
Specified Diameter, mm |
Permissible Variation, mm |
|
Plus |
Minus |
|
1.6-2.3 |
0.04 |
0.03 |
>2.3-3.05 |
0.05 |
0.05 |
>3.05-3.6 |
0.08 |
0.05 |
>3.6-4.8 |
0.1 |
0.08 |
Other Products
ASTM A475 Standard
Dia. of strand, in(mm) |
Minimum Breaking Strength of Strand,1bf(kN) |
Weight of Zine Coating, g/m2 |
|
High Strength Grade |
Extra High Strength Grade |
CLASS A |
|
3/16(4.76) |
2850(12.677) |
3990(17.748) |
153 |
1/4(6.35) |
2850(21.129) |
6650(29.581) |
183 |
5/16(7.94) |
8000(35.586) |
11200(49.820) |
244 |
3/8(9.52) |
10800(48.040) |
15400(68.503) |
259 |
7/16(11.11) |
14500(64.499) |
20800(92.523) |
275 |
1/2(12.70) |
18800(83.627) |
26900(119.657) |
275 |
ASTM B498 Standard
Home » Products » Standards » ASTM B498
Dia of Wire, mm |
Tensile Strength, Mpa |
Stress at 1% Extension, Mpa |
Coating, g/m2 |
|
CLASS A |
CLASS B |
|||
0.80-1.57 |
1000-1550 |
/ |
50-153 |
/ |
1.57-1.90 |
1000-1550 |
/ |
153-210 |
/ |
1.90-2.30 |
1000-1550 |
1310 |
220 |
440 |
2.30-2.70 |
1000-1550 |
1280 |
230 |
460 |
2.70-3.10 |
1000-1550 |
1280 |
240 |
480 |
3.10-3.50 |
1000-1550 |
1240 |
260 |
520 |
3.50-3.90 |
1000-1550 |
1170 |
270 |
540 |
3.90-4.50 |
1000-1550 |
1170 |
275 |
550 |
4.50-4.80 |
1000-1550 |
1170 |
300 |
|