Flexible Copper Conductor Welding Power Cable Single Or Double Insulation

 China Flexible Copper Conductor Welding Power Cable Single Or Double Insulation supplier

Flexible Copper Conductor Welding Power Cable Single Or Double Insulation image

Get a Quote Email to us

Brand Name :
CN CABLE

Model Number :
WELDING CABLE

Certification :
IS

Place of Origin :
Henan

MOQ :
1000meters

Payment Terms :
L/C, T/T

Delivery Time :
20days after payment

conductor :
Plain copper conductors, extra fine stranded to IS 8130/84 equivalents to BS 6360, IEC 60228 & HD 383

Insulation :
EPR or NBR

Welding Cable with EPR/NBR rubber jacket, according to IS 6830/84 equivalents to BS 6899 and DIN VDE 0282 part 6

Conductor resistance
according to IS: 8130/84 equivalent to HD 383 cl. 6.

Conductor resistance factor

at +20˚ C – see technical information

Temperature range
flexing -25˚ C to +80˚ C
fixed installation -40˚ C to +80˚ C
Admissible working temperature

at conductor +85˚

Nominal voltage 100V

Test voltage 1000V

Cable structure :

– Plain copper conductors, extra fine stranded to IS 8130/84 equivalents to BS 6360, IEC 60228 & HD 383.

– tape used as separator over the conductor.

– EPR/NBR outer rubber jacket, as per type SE-3.
– Outer sheathing black

– With marking of brand name and cross section.

– Testing of cable carried out as per IS 9857/90 equivalents to BS 638 part 4.

– Heat, oil and fire retardant cable.

Application
– Rubber insulated flexible welding cable are used to connect Welding Machine & for better welding proficiency.

– Used in Automobile industries, Shipbuilding, Transport, Steel Plans, Railways, Refineries, Oil fields, Automatic Welding Robots, Construction, Coal Mines etc.

– The robust construction makes these cables resistance to both cold & heat as well as to flames.

– They are suitable for use in open spaces and in dry and damp conditions.

Welding Cable with standard flexibility, bending radius : approx. 15 x CableØ

Cross-Sec
(Sq.mm)
Current Rating At a Max Duty Cycle No. of x Single
Wires WireØ
(mm)
Radial thickness
of sheathing
(mm)
Outer Diameter
min ~ max
(mm)
Max Resistance
@ 20˚C
(ohm/km)
AWG
No.
Permanent
100%
(Amps)
85%
(Amps)
60%
(Amps)
30%
(Amps)
1×16 513 x 0.2 2.0 8.7 ~ 10.7 1.210 135 146 174 246 6
1×25 783 x 0.2 2.0 10.5 ~ 12.5 0.780 177 192 228 343 4
1×35 497 x 0.3 2.0 12.1 ~ 14.1 0.554 221 240 285 403 2
1×50 702 x 0.3 2.2 14.0 ~ 16.0 0.386 279 303 360 509 1
1×70 999 x 0.3 2.4 16.2 ~ 18.2 0.272 352 382 454 643 2/0
1×95 1302 x 0.3 2.6 18.9 ~ 20.9 0.206 424 460 547 774 3/0
1×120 1702 x 0.3 2.8 20.2 ~ 23.2 0.161 491 525 601 814 4/0
1×150 2121 x 0.3 3.0 22.4 ~ 26.4 0.129 568 614 708 921 300Kcmil

Welding Cable with extreme high flexibility, bending radius : approx. 12 x CableØ :

Cross-Sec
(Sq.mm)
No. of x Single
Wires WireØ
(mm)
Radial thickness
of sheathing
(mm)
Outer Diameter
min ~ max
(mm)
Max
Resistance
@ 20˚C
(ohm/km)
AWG
No.
1×16 513 x 0.2 2.0 8.7 ~ 10.7 1.210 6
1×25 783 x 0.2 2.0 10.5 ~ 12.5 0.780 4
1×35 1120 x 0.2 2.0 12.1 ~ 14.1 0.554 2
1×50 1600 x 0.2 2.2 14.0 ~ 16.0 0.386 1
1×70 2240 x 0.2 2.4 16.2 ~ 18.2 0.272 2/0
1×95 3024 x 0.2 2.6 18.9 ~ 20.9 0.206 3/0

Safety Requirements
1. Coiled welding cable must always be spread out before using to avoid overheating in use.
2. Cables must not be spliced within 10 feet of the holder.
3. Welding cable must never be coiled or looped around the body of the worker.
4. Cables with damaged insulation must be replaced.
5. Welding cable must only be joined through the means of recommended connections.

We are China Flexible Copper Conductor Welding Power Cable Single Or Double Insulation manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , ,