Flame Retardant Medium Voltage Cable For Power Distribution Transmission Line

 China Flame Retardant Medium Voltage Cable For Power Distribution Transmission Line supplier

Flame Retardant Medium Voltage Cable For Power Distribution Transmission Line image

Get a Quote Email to us

Brand Name :
Huanghe

Model Number :
MV Power Cable

Certification :
IOS OHSAS CCC IEC

Place of Origin :
China

MOQ :
200

Payment Terms :
TT/Western Union /LC

Supply Ability :
50000meters per week

Delivery Time :
5-8days

Packaging Details :
wooden drum

Conductor Core :
Annealed Copper or Hard Drawn Aluminum

Insulation Material :
Crosslinked Polyethylene (XLPE)

Armoured Types :
DSTA/SWA/AWA or Unarmoured

Outer Sheath Material :
Polyvinyl Chloride (PVC)

Standard :
BS IEC ASTM DIN, IEC 60502-2, GB12706, IEC60228

Colour :
Black or As Requirement

Packing :
Wooden-steel Drum, Steel Drum, Wooden Drum

Special Requiremets :
Fire-resistant,flame retardant,low smoke halogen free

Sample :
Free Sample

Application :
Underground,Construction,Industrial,power distribution and transmission line

Voltage :
3.6kv to 35kv

Flame Retardant Medium Voltage Cable For Power Distribution Transmission Line

MV POWER CABLE STANDARD

International: IEC60502-2

National: GB/T 12706.1-2008

Other standards: such as BS, DIN and ICEA, design & manufacture special power cable according to customer’s special request.

MV POWER CABLE CONSTRUCTION

1. Conductor: Copper or aluminium (class1 or class 2)

2. Inner semi-conducting layer

3. Insulation: Cross inked polyethylene (XLPE)

4. Outer semi-conducting layer

5. Armoured or Unarmoured

6. Wrapping of conductive material

7. Screen: Braiding of copper wires or copper tape

8. Separator

9. Outer jacket: PVC compound

MV POWER CABLE APPLICATION

MV power cable is used for power distribution networks; also for connection to generation units and plant and process connection. The mv cable could be laid directly in ground, outdoors, indoors and in cable ducts.

MV POWER CABLE CHARACTERISTICS

The ambient temperature under installation should not be lower than: 0 °C

When the armored single core cable used for Alternative Current(AC) system, the armour material should be non-magnetic.

Usage characteristics

Packaging

Steel Wooden Drum

Minimum installation temperature

-20 °C

Max. conductor temperature in service

90 °C

Short-circuit max. conductor temperature

250 °C

Bending factor when laying

20 x D single core cable

15 x D multi-core cable

MV POWER CABLE TYPES

Type

Description

Cores

Cross Section

YJV22

Copper conductor/XLPE insulation/Steel Tape Armored/PVC outer sheath Power Cable

1, 3

25~1000mm2

YJV23

Copper conductor/XLPE insulation/Steel Tape Armored/PE outer sheath Power Cable

1, 3

25~1000mm2

ZA-YJV22 ZB-YJV22 ZC-YJV22

Copper conductor/XLPE insulation/Steel Tape Armored flame-retardant Power Cable

1, 3

25~1000mm2

WDZA-YJY23 WDZB-YJY23 WDZC-YJY23

Copper conductor/XLPE insulation/Steel Tape Armored Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) flame-retardant Power Cable

1, 3

25~1000mm2

1 CORE 12/20KV POWER CABLE DATA

No. of cores and cross -sec.

Operation
voltage
max.

Nominal
voltage
U0/U

Insulation
thickness

Sheath
thickness
Nominal
value

Outer Ø
approx.

weight
approx.

Current ratings in air 30℃

Current ratings buried 20℃

maximum DC resistance at 20℃

mm²

kV

kV

mm

mm

mm

kg / km

A

A

Ω/km

1 x 35

24

12/ 20

5.5

1.8

24.9

860

205

190

0.52

1 x 50

24

12/ 20

5.5

1.8

26.4

1138

245

225

0.39

1 x 70

24

12/ 20

5.5

1.9

28.1

1281

305

275

0.27

1 x 95

24

12/ 20

5.5

1.9

29.9

1570

370

330

0.19

1 x 120

24

12/ 20

5.5

2.0

31.3

1839

430

375

0.15

1 x 150

24

12/ 20

5.5

2.0

33.1

2174

490

425

0.12

1 x 185

24

12/ 20

5.5

2.1

34.7

2540

560

480

0.10

1 x 240

24

12/ 20

5.5

2.2

37.1

3120

665

555

0.08

1 x 300

24

12/ 20

5.5

2.2

39.5

3746

765

630

0.06

1 x 400

24

12/ 20

5.5

2.3

44.1

4863

890

725

0.05

1 x 500

24

12/ 20

5.5

2.4

47.6

5905

1030

825

0.04

1 x 630

24

12/ 20

5.5

2.5

51.3

7220

1190

940

0.03

3 CORE 12/20KV POWER CABLE DATA

No.cores

x

cross-sec.

Operation
voltage
max.

Nominal
voltage
U0/U

Insulation
thickness

Sheath
thickness
Nominal
value

Outer Ø
approx.

weight
approx.

Current ratings in air 30℃

Current ratings buried 20℃

maximum DC resistance at 20℃

mm²

kV

kV

mm

mm

mm

kg / km

A

A

Ω/km

3 x 35

24

12/20

5.5

2.6

52.5

3023

155

185

0.52

3 x 50

24

12/20

5.5

2.7

55.5

3891

180

218

0.39

3 x 70

24

12/20

5.5

2.8

59.3

4396

223

267

0.27

3 x 95

24

12/20

5.5

3.0

63

5264

271

318

0.19

3 x 120

24

12/20

5.5

3.1

66.2

6190

312

363

0.15

3 x 150

24

12/20

5.5

3.2

69.8

7240

363

417

0.12

3 x 185

24

12/20

5.5

3.3

73.7

8499

404

460

0.1

3 x 240

24

12/20

5.5

3.5

78.6

10353

471

531

0.08

3 x 300

24

12/20

5.5

3.6

83.8

12328

536

596

0.06

3 x 400

24

12/20

5.5

3.8

93.6

15921

630

684

0.05

We are China Flame Retardant Medium Voltage Cable For Power Distribution Transmission Line manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION