Fire Resistant XLPE Power Cable Medium Voltage For Underground / Construction
Fire Resistant XLPE Power Cable Medium Voltage For Underground / Construction image
Fire Resistant XLPE Power Cable Medium Voltage For Underground / Construction
MEDIUM VOLTAGE CABLE STANDARD
This medium voltage xlpe cable manufactured according to IEC60502, SANS 1339, BS 6622, AS/NZS1429.1, NFC 33226, CSA C-68.3, ICEA S-93-639, ICEA S-94-649, CSA C68.5, IS 7098, etc. standard as customer request.
MEDIUM VOLTAGE CABLE VOLTAGE
3.6/6KV, 6/10KV, 8.7/15KV, 12/20KV, 18/20KV, 21/35KV, 26/35KV
MEDIUM VOLTAGE CABLE CONSTRUCTION
Conductor: copper conductor or aluminum conductor
Conductor screen: Semi-conducting material
Insulation: XLPE (Cross-Linked Polyethylene)
Insulation Screen: Semi-conducting material
Metallic Screen: Ioverall copper tape screen
Filler: PET (Polyethylene Terephthalate) fibres
Separator: Binding tape
Bedding: PVC (Polyvinyl Chloride)
Armour: Steel Tape Armoured (STA) or Aluminium Wire Armoured (AWA) or Steel Wire Armoured (SWA) or unarmoured
Outer sheath: PVC (Polyvinyl Chloride) or Polyethylene (PE)
Colour: Black or as request
MEDIUM VOLTAGE CABLE APPLICATION
The product is suitable for power transmission and distribution lines with rated power frequency voltage up to and including 35KV. It is generally used for power networks, underground, outdoors and in cable ducting.
MEDIUM VOLTAGE CABLE CHARACTERISTICS
1. Rated voltages: 3.6/6 kV~26/35 kV
2. The ambient temperature for installation: ≥0℃
3. Maximum conductor temperature in normal operation:≤90℃
4. Max operating temperature of con. When cable short-circuited (5s maximum duration): 250℃
5. Minimum Bending Radius
Single core – Fixed: 15 x overall diameter
3 core – Fixed: 12 x overall diameter
(Single core 12 x overall diameter and 3 core 10 x overall diameter where bands are positioned adjacent to joint or terminations provided that the bending is carefully controlled by the use of a former)
XLPE INSULATED MEDIUM VOLTAGE CABLE TYPE & SIZE
Type |
Description |
Cores |
Cross Section |
YJV |
Copper Conductor/XLPE Insulation/PVC Outer Sheath Power Cable |
1, 3 |
25mm2-1000mm2 |
YJY |
Copper Conductor/XLPE Insulation/PE Outer Sheath Power Cable |
1, 3 |
25mm2-1000mm2 |
ZA-YJV ZB-YJV ZC-YJV |
Copper Conductor/XLPE Insulation Flame-Retardant Power Cable |
1, 3 |
25mm2-1000mm2 |
WDZA-YJY WDZB-YJY WDZC-YJY |
Copper Conductor/XLPE Insulation Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) Flame-Retardant Power Cable |
1, 3 |
25mm2-1000mm2 |
SINGLE CORE 8.7/15KV (Um=17.5KV) DIMENSIONAL DATA
Nominal Area of Conductor |
Maximum Conductor Resistance at 20°C |
Thickness of XLPE Insulation |
Thickness of Copper Tape |
Thickness of Outer Sheath |
Approx. Overall Diameter |
Approx. Cable Weight |
Standard Packing Length |
Drum size |
Approx. Gross Weight |
---|---|---|---|---|---|---|---|---|---|
Sqmm |
Ohm/Km |
mm |
mm |
mm |
mm |
Kg/Km |
Metre ± 10% |
|
Kg |
35 |
0.524 |
4.5 |
0.075 |
1.8 |
23.7 |
835 |
500 |
D-12 |
520 |
50 |
0.387 |
4.5 |
0.075 |
1.8 |
24.8 |
980 |
500 |
D-12 |
600 |
70 |
0.268 |
4.5 |
0.075 |
1.8 |
26.4 |
1220 |
500 |
D-12 |
720 |
|
|||||||||
95 |
0.193 |
4.5 |
0.075 |
1.8 |
28.3 |
1520 |
500 |
D-12 |
870 |
120 |
0.153 |
4.5 |
0.075 |
1.9 |
30.0 |
1800 |
500 |
D-12 |
1010 |
150 |
0.124 |
4.5 |
0.075 |
1.9 |
31.4 |
2110 |
500 |
D-14 |
1210 |
|
|||||||||
185 |
0.0991 |
4.5 |
0.075 |
2.0 |
33.2 |
2480 |
500 |
D-16 |
1450 |
240 |
0.0754 |
4.5 |
0.075 |
2.0 |
35.7 |
3070 |
500 |
D-18 |
1780 |
300 |
0.0601 |
4.5 |
0.075 |
2.1 |
37.9 |
3700 |
500 |
D-18 |
2090 |
|
|||||||||
400 |
0.0470 |
4.5 |
0.075 |
2.2 |
41.0 |
4620 |
500 |
D-18 |
2550 |
500 |
0.0366 |
4.5 |
0.075 |
2.3 |
44.2 |
5660 |
500 |
D-18 |
3070 |
630 |
0.0283 |
4.5 |
0.075 |
2.4 |
48.2 |
7040 |
500 |
D-19 |
3840 |
We are China Fire Resistant XLPE Power Cable Medium Voltage For Underground / Construction manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: Medium Voltage Cable, mv power cable, xlpe medium voltage cables