Electrical Overhead Service Drop Cable With AWG Aluminum Wire Conductor

 China Electrical Overhead Service Drop Cable With AWG Aluminum Wire Conductor supplier

Electrical Overhead Service Drop Cable With AWG Aluminum Wire Conductor image

Get a Quote Email to us

Brand Name :
TANO CABLE

Model Number :
Duplex Service Drop Cable

Certification :
ISO

Place of Origin :
CHINA

MOQ :
3000M

Price :
Negotiable

Payment Terms :
L/C, T/T, Western Union

Supply Ability :
5000 km Per Month

Delivery Time :
5-30 working days

Packaging Details :
By roll, wooden drum or steel-wooden drum

conductor :
aluminum

insulation :
XLPE

voltage :
0.6/1kV

application :
overhead

TANO CABLE 3/0 4/0 AWG Aluminum Wire Conductor XLPE Duplex Service Drop Cable

DESCRIPTION

Tano Cable's duplex service drop cable meets or exceeds the following ASTM specifications:

• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.

• B-231 Aluminum Conductors, Concentric-Lay-Stranded.

• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).

• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.

• B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire.

Tano Cable's duplex service drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.

TECHNICAL SPECIFICATION

1.

Code Word Phase Conductor Bare Neutral Messenger Weight
Per 1000ft.(Ibs.)
Allowable
Ampacities+
Size
(AWG)
Stranding Insul.
Thick.
(mils)
Size
(kcmil)
Stranding Rated Strength
(Ibs.)
XLP POLY XLP POLY
AAC NEUTRAL-MESSENGER
Patella 6 7 45 6 7 563 103 103 85 70
Oyster 4 7 45 4 7 881 154 154 115 90
Clam 2 7 45 2 7 1350 233 233 150 120
Murex 1/0 7 60 1/0 7 1990 374 374 205 160
Purpura 1/0 9 60 1/0 7 1990 368 368 205 160
Nassa 2/0 7 60 2/0 7 2510 462 462 235 185
Melita 3/0 17 60 3/0 19 3310 562 562 275 215
Portunus 4/0 18 60 4/0 19 4020 696 696 315 245
Nannynose 336.4 19 80 336.4 19 6146 1118 1118 420 325
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).
+ Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.

2.

Code Word Phase Conductor Bare Neutral Messenger Weight
Per 1000ft.(Ibs.)
Allowable
Ampacities+
Size
(AWG)
Stranding Insul.
Thick.
(mils)
Size
(kcmil)
Stranding Rated Strength
(Ibs.)
XLP POLY XLP POLY
ACSR NEUTRAL-MESSENGER
Paludina 6 1 45 6 43252 1190 109 109 85 70
Voluta 6 7 45 6 43252 1190 114 114 85 70
Whelk 4 1 45 4 43252 1860 164 115 90
Periwinkle 4 7 45 4 43252 1860 172 172 115 90
Conch 2 7 45 2 43252 2850 262 262 150 120
Neritina 1/0 7 60 1/0 43252 4380 420 420 205 160
Cenia 1/0 9 60 1/0 43252 4380 414 414 205 160
Runcina 2/0 7 60 2/0 43252 5310 520 520 235 185
Triton 2/0 11 60 2/0 43252 5310 512 512 235 185
Mursia 3/0 17 60 3/0 43252 6620 635 635 275 215
Zuzara 4/0 18 60 4/0 43252 8350 789 789 315 245
Limpet 336.4 19 80 336.4 43118 8680 1167 1167 420 325
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).
+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.

3.

Code Word Phase Conductor Bare Neutral Messenger Weight
Per 1000ft.(Ibs.)
Allowable
Ampacities+
Size
(AWG)
Stranding Insul.
Thick.
(mils)
Size
(kcmil)
Stranding Rated Strength
(Ibs.)
XLP POLY XLP POLY
ACSR REDUCED NEUTRAL-MESSENGER
Scallop 4 1 45 6 43252 1190 142 115 90
Strombus 4 7 45 6 43252 1190 151 151 115 90
Cockle 2 7 45 4 43252 1860 228 228 150 120
Janthina 1/0 7 60 2 43252 2853 366 366 205 160
Ranella 1/0 9 60 2 43252 2853 360 360 205 160
Cavolinia 2/0 7 60 1 43252 3550 453 453 235 185
Clio 2/0 11 60 1 43252 3550 444 444 235 185
Aega 3/0 17 60 1/0 43252 4380 549 549 275 215
Cerapus 4/0 18 60 2/0 43252 5310 681 681 315 245
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).
+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.

APPLICATION

Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene(XLP) XLPE insulated conductors.

CONSTRUCTION

Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or crosslinked polyethylene (XLP). Neutral messengers are concentrically stranded 6201, AAC, or ACSR.

drawings as below

Conductor: Hard drawm Aluminum Wire

Insulation: XLP

FACTORY OVERVIEW

PACKING

THE THIRD PARTY INSPECTION

WORK SHOP OVERVIEW

We are China Electrical Overhead Service Drop Cable With AWG Aluminum Wire Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.