Electrical Flexible Multicore Control Cable , PVC Insulated Control Cable
Electrical Flexible Multicore Control Cable , PVC Insulated Control Cable image
Brand Name :
CHINT
Model Number :
KVVP (Control cable)
Certification :
ISO9001, CE, CCC
Place of Origin :
CHINA
MOQ :
Negotiable
Price :
Negotiable
Packaging Details :
Wooden/Steel Reel
Material Shape :
Round Wire
Range of Application :
Flame Retardant
Insulation :
PVC/XLPE
Rated Voltage :
450/750V
Port :
Shanghai
Electrical Flexible Cable, PVC Insulated PVC Sheathed ControlFlexible Cable
Product Description
Standard
The control cable can be produced according to the standard GB9330-1988,IEC,DIN,BS,and the factory can also manufacture the cables in accordance with other standards.
Scope of Application
The control cable are suitable for the wiring of electrical controlling equipments and instrument,monitoring and controlling return circuit,electrical protection and measurement in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.
Service Conditions
(1) The long-time working temperature of conductor of PVC insulated cable is 70oC
The long-time working temperature of conductor of XLPE insulated cable is 90oC
(2) The temperature for laying the cables can not be lower than 0oC.Permissible bending radius(r):unarmoured cable:r≥6D;(D: outer diameter of the cable);armoured or copper-tape screened cable:r≥12D;shielded flexible cable:r≥6D
Type | Name | Section Area(mm2) | No. of Core | Application Site |
KVV | Copper Conductor,PVC Insulated and Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors,in cable ditches or pipes |
4 6 | 2-14 | |||
10 | 2-10 | |||
KVVP | Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded Control Cable | 0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 2-14 | |||
10 | 2-10 | |||
KVVP2 | Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable | 0.75 1.0 1.5 2.5 | 4-10 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 7-61 | |||
10 | 4-10 | |||
KVV22 | Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force |
4 6 | 4-14 | |||
10 | 4-14 | |||
KVVR | Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable | 0.5-2.5 | 4-61 | Installation indoors where flexibility and movability are required |
KVVRP | Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable | 0.5 0.75 1.0 | 4-61 | Installation indoors where flexibility shielding and movability are required |
1.5 2.5 | 4-48 | |||
KYJV | Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors,in cable ditches or pipes |
4 6 | 2-14 | |||
10 | 2-10 | |||
KYJVP | Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 2-14 | |||
10 | 2-10 | |||
KYJV22 | Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force |
4 6 | 4-14 | |||
10 | 4-10 | |||
KYJVP2 | Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 4-14 | |||
10 | 4-10 | |||
KYJVR | Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable | 0.5-2.5 | 4-61 | Installation indoors where flexibility and movability are required |
KYJVRP | Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable | 0.5 0.75 1.0 | 4-61 | |
1.5 2.5 | 4-48 | Installation indoors where flexibility shielding and movability are required |
Ordering Advice
Rated Voltage
Application Standard: IEC/BS/UL/GB
Number of Cores
Conductor Size & Construction
Type of Insulation
Armored or unarmored. If armor, the armor type & material
The Requirement of Sheath
Length of Cable & Packing Requirement
Other Requirement
PACKING AND SHIPPING
We are capable of meeting the strictest delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self-adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.
We are China Electrical Flexible Multicore Control Cable , PVC Insulated Control Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: armoured control cable, Flexible Control Cable, multicore control cable