Durable Galvanized Steel Wire Cable For Overhead Transmission Line Of ABC Aerial Bundled Cable

 China Durable Galvanized Steel Wire Cable For Overhead Transmission Line Of ABC Aerial Bundled Cable supplier

Durable Galvanized Steel Wire Cable For Overhead Transmission Line Of ABC Aerial Bundled Cable image

Get a Quote Email to us

Brand Name :
Litong Global

Model Number :
LT-054

Certification :
ISO9001-2008

Place of Origin :
Anhui,China

MOQ :
Negotiable

Price :
Negotiable

Supply Ability :
400tons/day

Packaging Details :
Standard export packing on drum

Model NO. :
galvanized steel wire

Conductor Type :
Stranded

Application :
Overhead, Guy Wire,Stay Wire

Conductor Material :
Steel

Standard :
ASTM A475,BS183

Transport Package :
Reel, Wooden Drum

Product Description
Hot dipped galvanized steel wire steel wire cable for ABC Cable
GSW (Galvanized Steel Wire)

1. Standards
ASTM A475: Standard Specification for Zinc-Coated Steel Wire Strand
ASTM B 498: Standard Specification for Zinc-Coated (Galvanized) Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR)
BS183: Specification for General Purpose Galvanized Steel Wire Strand
BS 50189: Conductors ofr overhead lines-Zinc coated steel wires
IEC 60888: Zinc-coated steel wires for stranded conductors
DIN 48200: Wires for stranded conductors
JIS G 3537: Zinc-coated steel wire strands
AS 1222.1: Steel conductors and stays-Bare overhead

2.Technical Data
Hot-Dipped Galvanized steel wire
Diameter:1.57~4.8mm
Zinc Coating:150-400g/m2 ASTM class A.
Tensile Strength:900-1720 mpa.
Intensity Level:General,High,Very High.
Min.No. of 360° twists:10~16.
Construction:1×7,1×19.

3. Application
Used as overhead ground wire or static wire on transmission lines, as pole or structure guy wires, and as messenger cable, fields and pastures division, animal containment.

4.Standard ASTM A 475

Number of
wires/
Nominal dia.
Approx.
strand dia.
Utilities grade Common grade Siemens-
martingrade
High-
strength grade
Extra high- strength grade Approx.
weight
No./mm Inch mm kN kN kN kN kN kg
3/2.64 7/32 5.56 6.228 10.409 15.569 21.796 131
3/3.05 1/4 6.35 14.012 8.274 13.523 21.040 29.981 174
3/3.05 1/4 6.35 20.017 174
3/3.30 9/32 7.14 9.252 15.035 23.398 33.362 204
3/3.68 5/16 7.94 28.913 11.076 18.193 28.246 40.479 255
3/4.19 3/8 9.52 37.810 14.813 24.732 37.187 52.489 328
7/1.04 1/8 3.18 2.402 4.048 5.916 8.140 48
7/1.32 5/32 3.97 3.870 6.539 9.519 13.078 76
7/1.57 3/16 4.76 5.115 8.452 12.677 17.748 109
7/1.65 3/16 4.76 10.676 119
7/1.83 7/32 5.56 6.850 11.387 17.126 24.020 146
7/2.03 1/4 6.35 8.452 14.012 21.129 29.581 180
7/2.36 9/32 7.14 20.462 11.432 18.905 28.469 39.812 244
7/2.64 5/16 7.94 14.234 23.798 35.586 49.820 305
7/2.77 5/16 7.94 26.689 335
7/3.05 3/8 9.52 51.155 18.905 30.915 48.040 68.503 407
7/3.68 7/16 11.11 80.068 25.355 41.591 64.499 92.523 595
7/4.19 1/2 12.70 111.206 32.917 53.823 83.627 119.657 770
7/4.78 9/16 14.29 42.703 69.837 108.981 155.688 1000
7/5.26 5/8 15.88 51.599 84.961 131.667 188.605 1211
19/2.54 1/2 12.70 33.895 56.492 84.961 118.768 751
19/2.87 9/16 12.49 42.881 71.616 107.202 149.905 949
19/3.18 5/8 15.88 48.930 80.513 124.995 178.819 1186
19/3.81 3/4 19.05 71.172 116.543 181.487 259.331 1721
19/4.50 7/8 22.22 97.416 159.691 248.211 354.523 2356
19/5.08 1 25.40 127.664 209.066 325.610 464.839 3089
37/3.63 1 25.40 125.885 205.508 319.827 456.832 3065
37/4.09 28.58 160.136 262.000 407.457 581.827 4010
37/4.55 31.75 198.391 324.720 505.318 721.502 4840

BS 183 standard

Number of wires/Dia. Approx. Strand Dia. Minimum Breaking Load of Strand Approx.Weight
Grade 350 Grade 480 Grade 700 Grade850 Grade 1000 Grade 1150 Grade 1300
mm kN kN kN kN kN kN kN kg/km
3/1.80 3.9 2.65 3.66 60
3/2.65 5.7 5.8 7.95 130
3/3.25 7 8.7 11.95 195
3/4.00 8.6 13.2 18.1 295
4/1.80 4.4 3.55 4.9 80
4/2.65 6.4 7.7 10.6o 172
4/3.25 7.9 11.6 15.9 260
4/4.00 9.7 17.6 24.1 35.2 390
5/1.50 4.1 3.1 4.24 6.18 69
5/1.80 4.9 4.45 6.1 8.9 95
5/2.65 7.2 9.65 13.25 19.3 220
5/3.25 8.8 14.5 19.9 29 320
5/4.00 10.8 22 30.15 43.95 490
7/O.56 1.7 0.6 0.83 1.2 1.7 1.98 2.24 14
7/0 71 2.1 0.97 1.33 1 94 2.75 3.19 3.6 28
7/0.85 2.6 1.39 1.9 2.8 3.95 4.57 5.15 31
7/0.90 2.7 1.55 2.14 3.1 4.45 5.12 5.8 35
7/l.00 3 1.92 2.64 3.85 5.5 6.32 7.15 43
7/1.25 3.8 3.01 4.1 6 8.55 9.88 11.15 67
7/1.40 4.2 3.75 5.17 7.54 9.16 10.75 12.35 14 84
7/RS* 4.3 3.85 5.28 7.7 9.35 11 12.65 14.3 86
7/1.60 4.5 4.9 6.75 9.85 11.95 14.1 16.2 18.3 110
7/1.80 5.4 6.23 8.55 12.45 17.8 20.5 23.2 140
7/2.00 6 7.7 10.55 15.4 22 25.3 28.6 170
7/2.36 7.1 10.7 14.7 21.4 30.6 35.2 39.8 240
7/2.65 8 13.5 18.5 27 38.6 44.4 50.2 300
7/3.00 9 17.3 23.75 34.65 49.5 56.9 64.3 392
7/3.15 9.5 19.1 26.2 38.2 54055 62.75 70.9 430
7/3.25 9.8 20.3 27.85 40.65 58.05 66.8 75.5 460
7/3.65 11 25.6 35.5 51.25 73.25 84.2 95.2 570
7/4.00 12 30.9 42.2 61.6 88 101 114 690
7/4.25 12.8 34.75 47.65 69.5 99.3 114 129 780
7/4.75 14 43.4 59.45 86.8O 124 142.7 161.3 970
19/1.00 5 5.22 7.16 10.45 14.92 17.16 19.4 120
19/1.25 6.3 8.16 11 .19 16.32 23.32 26.81 30.31 180
19/1.40 7 10.24 14.04 20.47 29.25 33.64 38.02 230
19/1.60 8 13.37 18.35 26.75 38.2 43.93 49.66 300
19/2.00 10 20.9 28.65 41.78 50.74 59.69 68.64 77.6 470
19/2.50 12.5 32.65 44.8 65.29 79.28 93.27 107.3 121.3 730
19/3.00 15 47 64.5 94 114.1 134.3 154.5 174.6 1050
19/3.55 17.8 65.8 90.27 131.6 159.9 188 216.3 244.5 1470
19/4.00 20 83.55 114.6 167.1 203 238.7 274.6 310.4 1870
19/4.75 23.8 117.85 161.6 235.7 286 336.7 387.2 437.7 2630

IEC 61089 standard

Nominal area St code number Area/mm2 Number of wires Diameter/mm Linear Mass/(kg/km) Rated strength/kN Max.D.C Resistance
(20ºC)/(Ω/km)
JGIA JGIB JG2A JG3A
30 4 27.1 7 2.22 6.66 213.3 36.3 33.6 39.3 43.9 7.1445
40 6.3 42.7 7 2.79 8.36 335.9 55.9 51.7 60.2 67.9 4.5362
65 10 67.8 7 3.51 10.53 553.2 87.4 80.7 93.5 103 2.8578
85 12.5 84.7 7 3.93 11.78 666.5 109.3 100.8 116.9 128.8 2.2862
100 16 108.4 7 4.44 13.32 853.1 139.9 129 199.7 164 1.7861
100 16 108.4 19 2.7 13.48 857 142.1 131.2 152.9 172.4 1.7944
150 25 169.4 19 3.37 16.85 1339.1 218.6 201.6 238.9 262.6 1.1484
250 40 271.1 19 4.26 21.31 2141.6 349.7 322.6 374.1 414.1 0.7177
250 40 271.1 37 3.05 21.38 2148.1 349.7 322.6 382.3 420.2 0.7196
400 63 427 37 3.83 26.83 3383.2 550.8 508.1 589.3 649 0.4569

FAQ

1)What kind of certifications do you have?
CCC, ISO9001-2000, SGS

2)Which markets do you involve mainly in?
Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc.

3)Which standards do you comply with when you produce the electrical wires and cables ?
We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.

6)What is the min.order quantity ?
It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request.

Any question or inquiry ,freely to contact us in the following :

We are China Durable Galvanized Steel Wire Cable For Overhead Transmission Line Of ABC Aerial Bundled Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION