Cu XLPE PVC Swa PVC (FR) 6.35/11kv to SANS 1339 Cable IEC60502 Cable Medium Voltage Swa Armoured Cable 3 Core 240mm

 China Cu XLPE PVC Swa PVC (FR) 6.35/11kv to SANS 1339 Cable IEC60502 Cable Medium Voltage Swa Armoured Cable 3 Core 240mm supplier

Cu XLPE PVC Swa PVC (FR) 6.35/11kv to SANS 1339 Cable IEC60502 Cable Medium Voltage Swa Armoured Cable 3 Core 240mm image

Get a Quote Email to us

Brand Name :
Yifang

Model Number :
Rubber

Certification :
ISO, CE, SGS

Place of Origin :
China

MOQ :
1000m

Price :
Negotiable

Payment Terms :
T/T, L/C

Supply Ability :
As per order quantity.

Delivery Time :
As per order quantity.

Packaging Details :
Wooden Drum, Steel Drum, Steel-wooden Drum.

Voltage :
11KV

Conductor :
Copper

Insulation :
XLPE

Sheath :
PVC

Application :
Under ground

Type :
medium voltage power cables

size :
240mm2 185mm2 150mm2 120mm2 95mm2 70mm2

standard :
IEC 50502 SANS 1339 BS 6622

Standard

The cable is manufactured according to IEC 60502.2, IEC 60502.1, AS/NZS 1429.1, AS/NZS 5000.1, BS 6622/7835, BS 5467, BS 6746, BS 6346, VDE 0276, ASTM, ABNT etc. It is suitable to be installed in the power line with rated voltage from (U0/U)0.6/1kV to 19/33kV for power transmission.

Application

The electric cable is applied to transmit and distribute power in power transmission and distribution system of 1kV~35kV or lower. It is widely adopted in the fields including power, construction, industry, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial re-place of PVC insulation or XLPE power cable.

Type Description Applications

N2XY/N2XSEY

NA2XY/NA2XSEY

Cu or AL conductor XLPE insulated PVC sheathed power cables. For laying indoors, in tunnels, in ducts. Able to bear extermal mechanical force but not large pulling forces. Single core cables are impermissible to be laid in magnetic ducts.

N2X2Y/N2XSE2Y

NA2X2Y/NA2XSE2Y

Cu or AL conductor XLPE insulated PE sheathed power cables.

N2XBY/N2XSEBY

NA2XBY/NA2XSEBY

Cu or AL conductor XLPE insulated PVC sheathed internal steel tape armoured power cables. For laying indoors, in tunnels, in ducts and underground. Able to bear extermal mechanical force but not large pulling forces, Impermissible to use single core cable in A.C circuit.

N2XB2Y/N2XSEB2Y

NA2XB2Y/NA2XSEB2Y

Cu or AL conductor XLPE insulated PE sheathed internal steel tape armoured power cables.

N2XRY/N2XSERY

NA2XRY/NA2XSERY

Cu or AL conductor XLPE insulated PVC sheathed internal steel wire armoured power cables. For laying in underground areas along route with large difference of elevation, in shafts and in water, able to bear a corresponding pulling forces and external mechanical forces.

N2XR2Y/N2XSER2Y

NA2XR2Y/NA2XSER2Y

Cu or AL conductor XLPE insulated PE sheathed internal steel wire armoured power cables.

Special features which we can offer for LV and MV cables:

* Watertight construction (both radial and longitudinal).
* Resistant to heavy vibration.
* Available in long delivery lengths to reduce number of joints.
* Corrosion-free screen area.
* Copper or aluminum conductor up to 800mm².
* Different options for outer PE jackets (LDPE, MDPE & HDPE).
* Different options for PVC, LSF, LSZH & FRPVC, being anti-termite or UV resistant as per

BS 7835, IEC 60332 etc.
* Strippable insulation screen.

* Increased armour conductivity by insertion of hard drawn copper wires in armour.

The maximum rated temperature of XLPE Power Cable

XLPE insulated,the maximum operating temperature of conductor shall exceed 90℃when the cable is used for long not period. The temperature of conductor shall not exceed 250℃ at short circuit for 5 seconds.

PVC insulated,the maximum operating temperature of conductor shall exceed 90℃ or 70 ℃ when the cable is used for long not period. PVC insulated the temperature of conductor shall not exceed 160℃ at short circuit for 5 seconds.

Installation requirement of XLPE Power Cable

The installation of cable is not limited by the difference of elevation along the route. The ambient temperature should not be below 0℃ during installation. The permissible bending radius for cable shall be complied with the following regulations:

For single-core: R>20(D+d) +/-5%

For multi-core: R>15(D+d) +/-5%

Where:R—bending radius (mm) , D—overall diameter of the cable (mm) , d—diameter of conductor (mm).

Single core cable of using in AC circuit shall be without armour or with steel wire armour and shall not be laid in magnetic ducs.

Rated voltage, No. of core and range of sectional area

Rate Voltage(kv): 0.6/1kV 1.8/3kV 3.6/6kV 6/10kV 8.7/15kV 12/20kV

18/30kV 21/35kV

Equivalent to : 0.6/1kV 1.9/3.3kV 3.8/6.6kV 6.35/11kV 8.7/15kV 12.7/22kV

19/33kV 21/35kV

No. of core and sectional area(mm2):

1 Core 1.5-800 25-800 25-1200 25-1200 35-1200 50-1200 50-1200

50-1200
2 Core 1.5-185 25-185
3 Core 1.5-400 25-400 25-400 25-400 35-400 50-400 50-400

50-400
4 Core 2.5-400 25-400
5 Core 2.5-400 25-400

We are China Cu XLPE PVC Swa PVC (FR) 6.35/11kv to SANS 1339 Cable IEC60502 Cable Medium Voltage Swa Armoured Cable 3 Core 240mm manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION