Copper Wire Rubber Insulated Cable , Double Insulated Cable 70mm2 120mm2

 China Copper Wire Rubber Insulated Cable , Double Insulated Cable 70mm2 120mm2 supplier

Copper Wire Rubber Insulated Cable , Double Insulated Cable 70mm2 120mm2 image

Get a Quote Email to us

Brand Name :
TANO CABLE

Model Number :
H07RN-F

Certification :
ISO CE ROHS

Place of Origin :
China

MOQ :
2000 Meters

Price :
Negotiable

Payment Terms :
L/C, T/T

Supply Ability :
20000 mts per month

Delivery Time :
7-25 work days

Packaging Details :
By wooden drum, steel-wooden drum and steel drum with strong protection to suit for the long-distance delivery

Key words :
Super Flex Welding Cable

Insulation :
EPR

Standard :
IEC66

Conductor :
Class-5

Sheath Material :
Neoprene Rubber

Temperature :
70 ℃

TANO CABLE Double Insulated Cable Copper Wire Welding Cable 70mm2 120mm2 YHF Welding Cable

Construction of rubber cable

Conductor: Flexible Class 5 Copper Conductor

Insualtion: Rubber Sheath

Sheath: Rubber Sheath

Application of rubber cable

These cables are used for lightweight hand and workshop tool while the other groups are suitable for increasingly higher levels of stress and heavy duty equipment.

Insulation Color of rubber cable

Single-Core: Black,
2-Core: Brown & Black,
3-Core: Brown, Blue & Green/Yellow
4-Core: Brown, Blue, Black & Green/Yellow
5-Core: Brown, Blue, Black, Grey & Green/Yellow

Sheath Color of rubber cable

Black

Rubber copper wire Working Conditions

1. Rated voltage :300/500(h05rn-f type),450/750V(h07rn-f type)

2. The long-term working temperature of conductor should be no longer than 65°C

3. W type cables have weather-proof character and certain grease-proof character and are suitable for outdoor usage and the occasion with greasy dirt.

4. ZR type cables have fire-retardant character.

Characteristics of rubber cable

1. Rated power-frequency voltage U0/U: 450/750V, 300/500V and 200/200V.

2. Maximum permitted operating temperature of conductor is 60°C.

3. Permitted lowest working temperature is -35°C.

4. Cables can be used at places contaminated by mineral oil and fuel oil.

Working temperature of rubber cable

H07RN-F model rated voltage U0/U IS 450/750V

H05RN-F model rated voltage U0/U IS 300/500V

H05RR-F model rated voltage U0/U IS 300/500V

Long time allow working temperature of wire core cant be higher than 60

Cross-Sectional
Area mm2
Number diameter of core Overall Diameter Max.D.C resistance
of at 20℃
MΩ/km
Approx Weight
(kg/km)
min max Copper Tinned-Copper YZ YZW
2×0.75 24/0.2 5.7 7.4 26 26.7 81.7 89.6
2×1 32/0.2 6.1 8 19.7 20 123 138
2×1.5 16/0.25 7.6 9.8 13.3 13.7 185 196
2×2.5 28/0.25 9 11.6 7.98 8.21 234 252
2×4 56/0.3 10.6 13.7 4.95 5.09 255 276
2×6 84/0.3 11.8 15.1 3.3 3.39 356 371
3×0.75 24/0.2 6.2 8.1 26 26.7 97.4 105
3×1 32/0.2 6.5 8.5 19.7 20 112 126
3×1.5 16/0.25 8 10.4 13.3 13.7 156 174
3×2.5 28/0.25 9.6 12.4 7.98 8.21 204 2019
3×4 56/0.3 11.3 14.5 4.95 5.09 285 302
3×6 84/0.3 12.6 16.1 3.3 3.39 398 423
4×0.75 24/0.2 6.8 8.8 26 26.7 117 125
4×1 32/0.2 7.1 9.3 19.7 20 134 148
4×1.5 16/0.25 9 11.6 13.3 13.7 186 206
4×2.5 28/0.25 10.7 13.8 7.98 8.21 255 270
4×4 56/0.3 12.7 13.8 4.95 5.09 356 374
4×6 84/0.3 14 17.9 3.3 3.39 465 482
Nominal cross
section area
of conductor
Maximum diamteter of
wires in conductor
Thickness of covering

Specified
value

Mean overall
diameter
Max. conductor
resistance
at 20°C
Lower
limit
Upper
limit
Untinned
wires
Tinned
wires
mm2 mm mm mm mm Ω/km
H01N2-D
10 0.21 2.0 7.7 9.7 1.91 1.95
16 0.21 2.0 8.8 11.0 1.21 1.24
25 0.21 2.0 10.1 12.7 0.780 0.795
35 0.21 2.0 11.4 14.2 0.554 0.565
50 0.21 2.2 13.2 16.5 0.386 0.393
70 0.21 2.4 15.3 19.2 0.272 0.277
95 0.21 2.6 17.1 21.4 0.206 0.210
120 0.51 2.8 19.2 24.0 0.161 0.164
150 0.51 3.0 21.1 26.4 0.129 0.132
185 0.51 3.2 23.1 28.9 0.106 0.108
240 0.51 3.4 25.8 32.1 0.0817 0.0801
H01N2-E
10 0.16 1.2 6.2 7.8 1.91 1.95
16 0.16 1.2 7.3 9.1 1.21 1.24
25 0.16 1.2 8.6 10.8 0.780 0.795
35 0.16 1.2 9.8 12.3 0.554 0.565
50 0.16 1.5 11.9 14.8 0.386 0.393
70 0.16 1.5 13.6 17.0 0.272 0.277
95 0.16 1.8 15.6 19.5 0.206 0.210
120 0.21 1.8 17.2 21.6 0.161 0.164
150 0.21 1.8 18.8 23.5 0.129 0.132
185 0.21 1.8 20.4 25.5 0.106 0.108
240 0.21 2.0 23.0 28.0 0.0817 0.0801

Packaging & Shipping

Packaging:

Material:

Steel wooden drum (fumigation)

Cable length in each drum: 500m/1000m or as per actual cable length requirements.

Drum size:

As per cable length and container size

*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!

Shipping:

Port: Tianjin, or other ports as per your requireents.

Sea freight:

FOB/C&F/CIF quotation are all available.

*For some countries such as Africa countries, middle east countries, our sea freight quotation is much cheaper than clients get from local shipping agency.

Our Services

Advantage:

1. Sufficient support for our tendering representatives.
2. OEM service available based on official & legal authorization.
3. Strict quality control system.
4. Faster lead time than our competitors.
5. Excellent quality with reasonable price.
6. Strong technical support (technical data, drawing, etc.)
7. Cable solutions to your particular requirements.

8. Free sample is available with economic express fee.

9. 12 months quality guarantee after delivery.

We are China Copper Wire Rubber Insulated Cable , Double Insulated Cable 70mm2 120mm2 manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION