Certificated Aluminum Conductor XLPE Insulation Aerial Bundled Cable

 China Certificated Aluminum Conductor XLPE Insulation Aerial Bundled Cable supplier

Certificated Aluminum Conductor XLPE Insulation Aerial Bundled Cable image

Get a Quote Email to us

Brand Name :
SHANCABLE

Model Number :
Aerial Bundle Cable

Certification :
ASTM B-231,B232,B399, ICEA S-79-474

Place of Origin :
Shanghai, China

MOQ :
0.5km

Price :
0.10-10.99USD/m

Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability :
1000km per Month

Delivery Time :
10Days or More

Packaging Details :
Wooden Drum or Steel Drum

Conductor :
Aluminium Conductor

Insulation :
XLPE or PVC

Rated Voltage :
0.6/1 KV

Structure :
4 Phase

Application :
Overhead Power Transmission Lines

Sheath :
No

Per Drum Length :
500 meters or as per request

Certificated Aluminum Conductor XLPE Insulation Aerial Bundled Cable

1. Applications

Aerial Bunch Cables are basically a compromise construction between Power cables and Overhead conductors. ABC cables are especially used at areas where the cost of underground networks is expensive. Bundles can include one or two additional conductors for public lighting and control pair.

2. Standards

QUADRUPLEX SERVICE DROP-ALUMINIUM CONDUCTOR

ASTM B-231,B-232 and B-399, ICEA S -79-474

Description

3 Phase conductors + 1 Messenger conductor ABC Cable

The aerial Bundled cables designed for overhead distribution lines have an insulated neutral messenger made of AAAC, which the insulated aluminium phase conductor are helically wound over it. Cables are rated at 0.6/1(1.2)kV and conform to IEC60502.

Construction

Conductor:

a) Phase – The phase conductor shall be of H68 Condition aluminium conductor and compacted circular stranded.

b) Neutral or messenger – The Neutral or messenger conductor shall be of aluminium alloy conductor and compacted circular stranded.

Insulation:

The phase, neutral conductors shall be extruded with polyethylene(PE) as insulation.

STANDARD NF C 33-209

NFA 2X

Phases Neutral/Messenger
Distribution Lines Pub. Lighting
Cable Type Number of Number of Avarage Resistance Conductance Number of Avarage Rated Resistance
core wire diameter at 20℃ at 30℃ core diameter Strength at 20℃
mm² mm² PCS mm ohm/km A mm² mm kN ohm/km
3×25+54.6 3×25 7 5.9 1.20 112 9.6 16.0 0.63
3×25+1×16+54.6 3×25 7 5.9 1.20 112 1×16 9.6 16.0 0.63
3×25+2×16+54.6 3×25 7 5.9 1.20 112 2×16 9.6 16.0 0.63
3×35+54.6 3×35 7 6.9 0.868 138 9.6 16.0 0.63
3×35+1×16+54.6 3×35 7 6.9 0.868 138 1×16 9.6 16.0 0.63
3×35+2×16+54.6 3×35 7 6.9 0.868 138 2×16 9.6 16.0 0.63
3×50+54.6 3×50 7 8.1 0.641 168 9.6 16.0 0.63
3×50+1×16+54.6 3×50 7 8.1 0.641 168 1×16 9.6 16.0 0.63
3×50+2×16+54.6 3×50 7 8.1 0.641 168 2×16 9.6 16.0 0.63
3×70+54.6 3×70 12 9.7 0.443 213 9.6 16.0 0.63
3×70+1×16+54.6 3×70 12 9.7 0.443 213 1×16 9.6 16.0 0.63
3×70+2×16+54.6 3×70 12 9.7 0.443 213 2×16 9.6 16.0 0.63
3×70+1×25+54.6 3×70 12 9.7 0.443 213 1×25 9.6 16.0 0.63
3×70+2×25+54.6 3×70 12 9.7 0.443 213 2×25 9.6 16.0 0.50
3×70+70 3×70 12 9.7 0.443 213 10.2 20.6 0.50
3×70+1×16+70 3×70 12 9.7 0.443 213 1×16 10.2 20.6 0.50
3×70+2×16+70 3×70 12 9.7 0.443 213 2×16 10.2 20.6 0.50
3×95+70 3×95 12 11.5 0.320 258 10.2 20.6 0.50
3×95+1×16+70 3×95 12 11.5 0.320 258 1×16 10.2 20.6 0.50
3×95+2×16+70 3×95 12 11.5 0.320 258 2×16 10.2 20.6 0.50
3×120+70 3×120 12 12.8 0.253 300 10.2 20.6 0.50
3×120+1×16+70 3×120 19 12.8 0.253 300 1×16 10.2 20.6 0.50
3×120+2×16+70 3×120 19 12.8 0.253 300 2×16 10.2 20.6 0.50
3×150+70 3×150 19 14.5 0.206 344 10.2 20.6 0.50
3×150+1×16+70 3×150 19 14.5 0.206 344 1×16 10.2 20.6 0.50
3×150+2×16+70 3×150 19 14.5 0.206 344 2×16 10.2 20.6 0.50
3×120+95 3×120 19 12.8 0.253 300 12.9 27.9 0.343
3×120+1×16+95 3×120 19 12.8 0.253 300 1×16 12.9 27.9 0.343
3×120+2×16+95 3×120 19 12.8 0.253 300 2×16 12.9 27.9 0.343
3×150+95 3×150 19 14.5 0.206 344 12.9 27.9 0.343
3×150+1×16+95 3×150 19 14.5 0.206 344 1×16 12.9 27.9 0.343
3×150+2×16+95 3×150 19 14.5 0.206 344 2×16 12.9 27.9 0.343

Schedule of technical particulars

Phase conductor
Nominal cross-sectional area mm² 16 16 25 35 50 70 95 120 150 185
Number of cores 1 3 3 3 3 3 3 3 3 3
Minimum number of wires 6 6 6 6 6 12 15 15 30 30
Nominal insulation thickness mm 1 1 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0
Diameter of insulated core mm 6.8 6.8 8.5 9.5 11.2 13.0 15.1 16.6 18.4 20.6
Max. DC resistance at 20℃ ohm/km 1.91 1.91 1.20 0.868 0.641 0.443 0.320 0.253 0.206 0.164
Current rating at still wind, ambient A 61 61 84 104 129 167 209 246 283 332
temperature=30℃
Conductor temperature=75℃
Messenger conductor
Nominal cross-sectional area mm² 25 25 25 25 35 50 70 70 95 120
Minimum number of wires 6 6 6 6 6 6 12 12 15 15
Nominal insulation thickness mm 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.6 1.6
Diameter of insulated core mm 8.5 8.5 8.5 8.5 9.5 11.2 13.1 13.1 15.1 16.6
Max. DC resistance at 20℃ ohm/km 1.312 1.312 1.312 1.312 0.943 0.693 0.469 0.469 0.349 0.273
Calculated breaking load kN 6.4 6.4 6.4 6.4 8.9 12.1 18.0 18.0 24.2 30.8
Completed cable
Approx. overall diameter mm 15.3 19.0 23.2 25.6 30.0 34.9 40.6 44.1 49.2 54.9
Approx. weight of cable kg/km 160 290 400 500 680 920 1270 1510 1870 2340
Packing length m/drum 1000 1000 1000 1000 1000 1000 500 500 500 500

PACKING AND SHIPPING

We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.

Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.

We are China Certificated Aluminum Conductor XLPE Insulation Aerial Bundled Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION