BS 5467 Copper Conductor Flexible Armored Cable Single Core Aluminum Wire PVC 0.6 / 1kV Cable

 China BS 5467 Copper Conductor Flexible Armored Cable Single Core Aluminum Wire PVC 0.6 / 1kV Cable supplier

BS 5467 Copper Conductor Flexible Armored Cable Single Core Aluminum Wire PVC 0.6 / 1kV Cable image

Get a Quote Email to us

Brand Name :
CN CABLE

Model Number :
YJV72

Certification :
BS

Place of Origin :
Henan, China

MOQ :
1000meter

rated voltage :
600/1000v

number of core :
single

conductor :
Class 2 stranded copper wire

insulation :
XLPE

bedding :
PVC

armour :
AWA

sheath :
PVC

BS 5467 Copper Conductor Armoured Power Cable Single Core Aluminum Wire PVC 0.6 / 1kV Cable

APPLICATION

Single core PVC cable with aluminium wire armour (AWA). Power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting.

CONSTRUCTION
Conductor
Class 2 stranded copper conductor according to
BS EN 60228 (previously BS 6360)
Insulation
XLPE (Cross-Linked Polyethylene)
Bedding
PVC (Polyvinyl Chloride)
Armour
AWA (Aluminium Wire Armour)
Sheath
PVC (Polyvinyl Chloride)

CHARACTERISTICS
Voltage Rating (Uo/U)
600/1000V
Temperature Rating
Fixed: -25°C to +90°C
Minimum Bending Radius
25mm2 and above – Fixed: 8 x overall diameter
Core Identification
1 core: Brown or Blue
Sheath Colour
Black

DIMENSIONS
BS5467 XLPE/PVC/AWA/PVC (Copper)

NO. OF
CORES
NOMINAL CROSS
SECTIONAL AREA
mm²
NOMINAL
THICKNESS OF
INSULATION
mm
NOMINAL OVERALL
DIAMETER
mm
NOMINAL
WEIGHT
kg/km
Under
Armour
Overall
1
1
1
1
1
1
1
1
1
1
1
1
1
50
70
95
120
150
185
240
300
400
500
630
800
1000
1
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2
2.2
2.4
2.6
2.8
12.7
14.7
16.6
18.5
20.8
23.2
26
28.6
32.4
36
40
45.6
50.6
17.5
20.2
22.3
24.2
27.4
30
32.8
35.6
40.5
44.2
48.8
55.4
60.6
800
960
1240
1510
1900
2320
2930
3580
4600
5770
7250
9381
11540

CONDUCTORS
Class 2 Stranded Conductors for Single Core and Multi-Core Cables

NOMINAL CROSS
SECTIONAL AREA
mm²
MINIMUM NO. OF WIRES IN CONDUCTOR MAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC
Circular Circular Compacted Shaped Annealed Copper Conductor
CU AL CU AL CU AL Plain Wires
ohms/km
50
70
95
120
150
185
240
300
400
630
800
1000
19
19
19
37
37
37
37
61
61
91
91
91
19
19
19
37
37
37
37
61
61
91
91
91
6
12
15
18
18
30
34
34
53
53
53
53
6
12
15
15
15
30
30
30
53
53
53
53
6
12
15
18
18
30
34
34
53
53

6
12
15
15
15
30
30
30
53
53

0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.047
0.0283
0.0.221
0.0176

ELECTRICAL CHARACTERISTICS XLPE/PVC/AWA/PVC
Current Carrying Capacity

NOMINAL CROSS
SECTIONAL AREA
mm²
REFERENCE METHOD C
(CLIPPED DIRECT)
REFERENCE METHOD F
(IN FREE AIR OR ON A PERFORATED CABLE TRAY, HORIZONTAL OR VERTICAL)
TOUCHING TOUCHING SPACED BY ONE CABLE DIAMETER
2 Cables
Single-Phase
AC or DC
Flat
Amps
3 or 4 Cables
Three-Phase
AC Flat
Amps
2 Cables
Single-Phase
AC or DC
Flat
Amps
3 Cables
Three-Phase
AC Flat
Amps
3 Cables
Three-Phase
AC Trefoil
Amps
2 Cables DC
Amps
2 Cables
Single-Phase AC
Amps
3 or 4 Cables
Three-Phase AC
Amps
Horizontal Vertical Horizontal Vertical Horizontal Vertical
50
70
95
120
150
185
240
300
400
500
630
800
1000
237
303
367
425
488
557
656
755
853
962
1082
1170
1261
220
277
333
383
437
496
579
662
717
791
861
904
961
253
322
389
449
516
587
689
792
899
1016
1146
1246
1345
232
293
352
405
462
524
612
700
767
851
935
987
1055
222
285
346
402
463
529
625
720
815
918
1027
1119
1214
284
356
446
519
600
688
815
943
1137
1314
1528
1809
2100
270
349
426
497
575
660
782
906
1094
1266
1474
1744
2026
282
357
436
504
566
643
749
842
929
1032
1139
1204
1289
266
337
412
477
539
614
714
805
889
989
1092
1155
1238
288
358
425
485
549
618
715
810
848
923
992
1042
1110
266
331
393
449
510
574
666
755
797
871
940
978
1041

Voltage Drop

NOMINAL

CROSS

ECTIONAL

AREA

mm²

TWO

CORE

CABLE

DC

REFERENCE METHOD C & F

(CLIPPED DIRECT, ON TRAY OR IN FREE AIR)

2 Cables Single-Phase AC

mV/A/m

3 or 4 Cables Three-Phase AC

mV/A/m

Touching Spaced* Trefoil and Touching Flat and Touching Flat and Spaced*
r x z r x z r x z r x z r x z

50

70

95

120

150

185

240

300

400

500

630

800

1000

0.980

0.670

0.490

0.390

0.310

0.250

0.195

0.155

0.115

0.093

0.073

0.056

0.045

0.990

0.680

0.510

0.410

0.330

0.270

0.210

0.170

0.145

0.125

0.105

0.090

0.092

0.210

0.200

0.195

0.190

0.185

0.185

0.180

0.175

0.170

0.170

0.165

0.160

0.155

1.000

0.710

0.550

0.450

0.380

0.330

0.280

0.250

0.220

0.210

0.195

0.190

0.180

0.980

0.690

0.530

0.430

0.360

0.300

0.240

0.195

0.180

0.165

0.150

0.145

0.140

0.29

0.29

0.28

0.27

0.27

0.26

0.26

0.25

0.24

0.24

0.23

0.23

0.21

1.00

0.75

0.60

0.51

0.45

0.40

0.35

0.32

0.30

0.29

0.27

0.27

0.25

0.860

0.590

0.440

0.350

0.290

0.230

0.180

0.145

0.125

0.105

0.092

0.086

0.080

0.180

0.170

0.170

0.165

0.160

0.160

0.155

0.150

0.150

0.145

0.145

0.140

0.135

0.870

0.620

0.470

0.390

0.330

0.280

0.240

0.210

0.195

0.180

0.170

0.165

0.155

0.840

0.600

0.460

0.380

0.310

0.260

0.210

0.170

0.160

0.145

0.135

0.130

0.125

0.250

0.250

0.240

0.240

0.230

0.230

0.220

0.220

0.210

0.200

0.195

0.180

0.170

0.88

0.65

0.52

0.44

0.39

0.34

0.30

0.28

0.27

0.25

0.24

0.23

0.21

0.840

0.620

0.490

0.410

0.340

0.290

0.240

0.200

0.200

0.190

0.175

0.175

0.165

0.330

0.320

0.310

0.300

0.290

0.290

0.280

0.270

0.270

0.240

0.230

0.195

0.180

0.90

0.70

0.58

0.51

0.45

0.41

0.37

0.34

0.33

0.31

0.29

0.26

0.24

We are China BS 5467 Copper Conductor Flexible Armored Cable Single Core Aluminum Wire PVC 0.6 / 1kV Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION