Bare Copper Conductor 120mm2 Fire Rated Electrical Cable , 4 Core XLPE LSZH Cable

 China Bare Copper Conductor 120mm2 Fire Rated Electrical Cable , 4 Core XLPE LSZH Cable supplier

Bare Copper Conductor 120mm2 Fire Rated Electrical Cable , 4 Core XLPE LSZH Cable image

Get a Quote Email to us

Brand Name :
OEM

Certification :
CB, CE

Place of Origin :
China

MOQ :
500 M

Price :
Negotiation

Payment Terms :
T/T, L/C, D/P, West Union, Paypal, Secure Payments

Delivery Time :
15-20 working days or Negotiation

Packaging Details :
Standard export package

rated voltage :
0.6/1 kV

No.of cores :
4 cores

Fire Barrrier :
Mica-tape

Conductor :
Bare copper

Insulation :
XLPE

Sheath :
LSZH

Four Core Fire Resistant Cable Wire For Local Energy Distributions

Applications

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
Construction

1. Conductors

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
2. Insulation

XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90°C continuous operation.
3. Assembly / Inner Covering

The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The material is compatible with the insulating material,The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
4. Armour

Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
5. Outer Sheath

Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
6. Fire Performance of Cable Sheaths

Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.

Physical and Electrical Characteristics:

No.cores x
cross-sec.
Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm kg / km A A Ω/km
4×4 1.0 1.8 14.9 339 30 38 4.61
4×6 1.0 1.8 16.1 436 38 48 3.08
4×10 1.0 1.8 19.3 669 53 66 1.83
4×16 1.0 1.8 21.8 953 70 86 1.15
4×25 1.2 1.8 26.0 1374 94 112 0.73
4×35 1.2 1.8 28.7 1810 116 135 0.52
4×50 1.4 1.9 29.5 2312 139 161 0.39
4×70 1.4 2.1 33.0 3105 177 202 0.27
4×95 1.6 2.2 38.1 4179 217 240 0.19
4×120 1.6 2.4 41.1 5185 254 274 0.15
4×150 1.8 2.5 45.8 6414 294 309 0.12
4×185 2.0 2.7 50.5 7901 337 346 0.10
4×240 2.2 2.9 55.7 10249 401 403 0.08
4×300 2.4 3.1 63.4 13365 470 459 0.06

INSTALLATION METHOD DETAILS

A1 – Thermally insolated wall (Single-core) A2 – Thermally insolated wall (multi-core) B1 – Apparent electroduct (Single-core) B2 – Apparent electroduct (multi-core)
B1 – Electroduct in brickwork (Single-core) B1 – Electroduct in brickwork (multi-core) C – On the wall  C – On the ceiling
C – Non-perforated tray F – Perforated tray (Single-core) F – Perforated tray (multi-core) F –Suspended (Single-core)
E – Suspended (multi-core) B2 – Construction space B2 – Construction space B1 – Electroduct (Single-core)
B2 – Electroduct (Multi-core) B2 – Closed raceway embedded in floor (multi-core) B2 – Closed raceway embedded in floor (multi-core) B1 – Ventilated raceway embedded in floor
C – Embedded in the brickwork D – Buried in additional mechanical protection

Cable Drum Data

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300

WARRANTY

For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

We are China Bare Copper Conductor 120mm2 Fire Rated Electrical Cable , 4 Core XLPE LSZH Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , , ,