American Standard UL Industrial Cables THHN / THWN-2 / MTW

 China American Standard UL Industrial Cables THHN / THWN-2 / MTW supplier

American Standard UL Industrial Cables THHN / THWN-2 / MTW image

Get a Quote Email to us

Place of Origin :
China

Certification :
ISO,CCC,CE,CB,UL

Model Number :
THHN / THWN-2 / MTW

MOQ :
1000 meters

Packaging Details :
100~1000 meters per roll/drum or as per request

Delivery Time :
7~30 days as per order

Payment Terms :
TT

Supply Ability :
100000 meters per week

Brand Name :
Sino

American Standard UL Industrial Cables
THHN / THWN-2 / MTW

Application and Description

Type THHN/THWN conductors are primarily used in conduit for services, feeder, and branch circuits in commercial or industrial applications as specified in the National Electrical Code®.
When used as type THHN, conductor is suitable for use in dry locations at temperatures not to exceed 90°C.
When used as type THWN, conductor is suitable for use at temperatures not to exceed 90°C, dry locations or 75°C wet locations or not to exceed 75°C when exposed to oil or coolant. When used as type THWN-2, conductor is suitable for use in wet and dry locations at temperatures not to exceed 90°C or not to exceed 75°C when exposed to oil or coolant. When used as type MTW, conductor is suitable for use in wet locations, or when exposed to oil or coolant at temperatures not to exceed 60°C, or dry locations at temperatures not to exceed 90°C (with ampacity limited to that for 75°C conductors per NFPA 79). Conductor temperatures not to exceed 105°C in dry locations when rated AWM and used as appliance wiring material. Voltage rating for all applications is 600 volts.

Cable Construction

Conductor:
Soft annealed bare copper, Class B
stranding per ASTM B8
Insulation:
Tough, heat and moisture resistant Polyvinyl chloride (PVC) insulation over which a nylon (polyamide) jacket is applied.
Color:
upon request, black is preferable

Technical Compliances

– UL 83 – Thermoplastic-Insulated Wires and Cables
– CSA C22.2 No. 75-03
– UL 1063 (MTW) – Machine-Tool Wires and Cables (stranded cables only)
– UL 758 (AWM)
– ICEA S-95-658/NEMA WC 70

Cable Parameter

AWG OR KCMIL STRAND NOMINAL INSULATION THICKNESS INCH/MM NOMINAL JACKET THICKNESS INCH/MM NOMINAL OVERALL DIAMETER INCH/MM CABLE WEIGHT
LBS/KFT KG/KM
14 1 0.015 0.38 0.004 0.10 0.11 2.79 15 22
12 1 0.015 0.38 0.004 0.10 0.12 3.05 23 34
10 1 0.020 0.51 0.004 0.10 0.15 3.81 37 54
14 19 0.015 0.38 0.004 0.10 0.11 2.79 16 24
12 19 0.015 0.38 0.004 0.10 0.13 3.30 24 36
10 19 0.020 0.51 0.004 0.10 0.17 4.32 39 58
8 19 0.030 0.76 0.005 0.13 0.22 5.59 63 94
6 19 0.030 0.76 0.005 0.13 0.26 6.60 98 145
4 19 0.040 1.01 0.006 0.15 0.33 8.38 157 234
3 19 0.040 1.01 0.006 0.15 0.36 9.14 193 287
2 19 0.040 1.01 0.006 0.15 0.39 9.91 240 357
1 19 0.050 1.27 0.007 0.18 0.43 10.92 300 446
1/0 19 0.050 1.27 0.007 0.18 0.47 11.94 376 560
2/0 19 0.050 1.27 0.007 0.18 0.52 13.21 467 695
3/0 19 0.050 1.27 0.007 0.18 0.57 14.48 581 864
4/0 19 0.050 1.27 0.007 0.18 0.64 16.26 724 1077
250 37 0.060 1.52 0.008 0.20 0.69 17.53 855 1272
300 37 0.060 1.52 0.008 0.20 0.76 19.30 1022 1521
350 37 0.060 1.52 0.008 0.20 0.79 20.07 1191 1772
400 37 0.060 1.52 0.008 0.20 0.85 21.59 1345 2001
500 37 0.060 1.52 0.008 0.20 0.94 23.88 1668 2482
600 61 0.070 1.78 0.009 0.23 1.10 27.94 1994 2967
750 61 0.070 1.78 0.009 0.23 1.16 29.46 2465 3668

http://www.electriccablechina.com [email protected]

We are China American Standard UL Industrial Cables THHN / THWN-2 / MTW manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.