Aluminium Stranded Bare Conductor Alloy Reinforced ACAR

 China Aluminium Stranded Bare Conductor Alloy Reinforced ACAR supplier

Aluminium Stranded Bare Conductor Alloy Reinforced ACAR image

Get a Quote Email to us

Brand Name :
SHANCABLE

Model Number :
BC-ACAR

Certification :
IEC61089

Place of Origin :
Shanghai, China

MOQ :
10km

Price :
0.10-10.99USD/m

Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability :
1000km per Month

Delivery Time :
15 Days or More

Packaging Details :
Wooden Drum or Steel Drum

External Conductor :
Aluminium

Inner Conductor :
Aluminium Alloy

No. of Wires :
7pcs~73pcs

Cross-sectional Area :
12mm²~900mm²

Application :
Overhead Power System

Insulation :
No

Sheath :
No

Aluminium Stranded Bare Conductor Alloy-reinforced (ACAR) 16mm²~1250mm²

  • Place of Origin: Shanghai, China (Mainland)
  • Brand Name: SHANCABLE, OEM
  • Model Number: Overhead Conductor ACSR, AAC, AAAC, ACSS, AACSR, ACAR
  • Insulation Material: Bare conductor
  • Type: Overhead, Medium Voltage, High voltage, low voltage bare conductor
  • Application: Overhead, Overhead conductor Distribution Line and Transmission line
  • Conductor Material: aluminum or aluminium alloy, Aluminum, aluminium alloy, steel, carbon core
  • Jacket: Bare conductor
  • Productor name: Overhead Conductor ACSR AAC AAAC ACSR ACAR Bare Conductor
  • Insulation: Non-insulation bare conductor
  • Usage: State Grid, Power station, Transmission Line,overhead line
  • Standard: BS,ASTM,IEC
  • port of shipment: Shanghai
  • Certificates: ISO, CCC, KEMA
  • High Quality: PICC ensured

ACAR IEC 61089
Diameter Number of Wirers Area Linear Rated Max D.C. Resis-
Code Number Wire Cond. Al. Alloy Al. Alloy Total Mass strength tance at 20℃
mm mm mm mm mm2 mm2 mm2 kg/km kN Ω/km
16 1.76 5.28 4 3 9.73 7.30 17.0 46.6 3.85 1.7896
25 2.20 6.60 4 3 15.2 11.4 26.6 72.8 5.93 1.1453
40 2.78 8.35 4 3 24.3 18.3 42.6 116.5 9.25 0.7158
63 3.49 10.5 4 3 38.3 28.7 67.1 183.5 14.38 0.4545
100 4.40 13.2 4 3 60.8 45.6 106 291.2 22.52 0.2863
125 2.97 14.9 12 7 83.3 48.6 132 362.7 27.79 0.2302
160 3.36 16.8 12 7 107 62.2 169 464.2 35.04 0.1798
200 3.76 18.8 12 7 133 77.8 211 580.3 43.13 0.1439
250 4.21 21.0 12 7 167 97.2 264 725.3 53.92 0.1151
250 3.04 21.3 18 19 131 138 269 742.2 60.39 0.1154
315 3.34 23.4 30 7 263 61.3 324 892.6 60.52 0.0916
315 3.42 23.9 18 19 165 174 339 935.1 76.09 0.0916
400 3.76 26.3 30 7 334 77.8 411 1133.5 75.19 0.0721
400 3.85 27.0 18 19 210 221 431 1187.5 95.58 0.0721
450 3.99 27.9 30 7 375 87.6 463 1275.2 84.59 0.0641
450 4.08 28.6 18 19 236 249 485 1335.9 107.52 0.0641
500 4.21 29.4 30 7 417 97.3 514 1416.9 93.98 0.0577
500 4.31 30.1 18 19 262 277 539 1484.3 119.47 0.0577
560 4.45 31.2 30 7 467 109 576 1586.9 105.26 0.0515
560 3.45 31.0 54 7 504 65.4 570 1571.9 101.54 0.0516
630 3.71 33.4 42 19 454 205 660 1820.0 130.25 0.0458
630 3.79 34.1 24 37 271 417 688 1897.5 160.19 0.0458
710 3.94 35.5 42 19 512 232 743 2051.2 146.78 0.0407
710 4.02 36.2 24 37 305 470 775 2138.4 180.53 0.0407
800 4.18 37.6 42 19 577 261 838 2311.2 165.39 0.0361
800 4.27 38.4 24 37 344 530 873 2409.5 203.41 0.0361
900 4.43 39.9 42 19 649 294 942 2600.1 186.06 0.0321
900 3.66 40.2 54 37 567 388 955 2638.4 199.54 0.0321
1000 3.80 41.8 72 19 816 215 1032 2849.1 190.94 0.0289
1000 3.85 42.4 54 37 630 432 1061 2931.6 221.71 0.0289
1120 4.02 44.2 72 19 914 241 1155 3191.0 213.85 0.0258
1120 4.08 44.9 54 37 705 483 1189 3283.4 248.32 0.0258
1250 4.25 46.7 72 19 1020 269 1289 3561.4 238.68 0.0231
1250 4.31 47.4 54 37 787 539 1327 3664.5 277.14 0.0231
1400 4.50 49.4 72 19 1143 302 1444 3988.8 267.32 0.0207

Application

The bare conductor:AAC,AAAC,ACSR,AACSR,ACAR and Galvanized steel wire, are used in overhead electrical power transmission and distribution lines with various grade voltage.

Construction: Bare aluminum alloy 1350-H19 wires, concentrically stranded around a Class A galvanized coated steel core wire. ACSR consists of a galvanized steel core of 1 wire, 7 wires, 19 wires etc. surrounded by concentric layers of aluminum wire.

Standards

Our Bare conductor can meet or exceedthe item of cable international standards, such as:IEC 61089, BS 215 part1(AAC), BS 215 part2, BS 324201 (AAAC), DIN 48201 part 5 (AAC), DIN 48204, ASTM B231(AAC), ASTM B232(ACSR), BS EN 50182, BS EN 50183(AAAC), GB/T 1179-2008. Also we accept the OEM and the new design cable as customers.

Specification

1. Aluminum conductor

2. Concentric-Lay-Stranded

3. Coated Steel Reinforced

4. ASTM,BS,CSA,DIN,IEC etc. Standards

Following the American Standards ( ASTM )

B-230 Aluminum Wire, 1350-H19 for Electrical Purposes

B-231 Aluminum Conductors, Concentric-Lay-Stranded

B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)

B-341 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)

B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

Type Description No. of Wire Section Area
(mm2)
AAC All Aluminum Conductor 7~127 16~1500
AAAC All Aluminum Alloy Conductor 7~91 17~1300
ACSR Aluminum Conductors
Steel Reinforced
7~103 16~1250
AACSR Aluminum Alloy Conductors
Steel Reinforced
7~103 16~1250
ACAR/AW Aluminum Conductors
Aluminum Alloy Reinforced
7~103 16~1250
ACSW/S Aluminum Conductors
Aluminum Clad Steel Wire/Strand
7~103 16~1250
GSW Galvanized Steel Wire 3/2.64~37/4.55 16.41~765.99

We are China Aluminium Stranded Bare Conductor Alloy Reinforced ACAR manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.