Aluminium Aerial Bundled Cables
Aluminium Aerial Bundled Cables image
Brand Name :
SHANCABLE
Model Number :
ABC-0.6/1 KV AL/PVC
Certification :
TS 11654, NF C 33-209
Place of Origin :
Shanghai, China
MOQ :
0.5km
Price :
0.50-30.99USD/m
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :
1000km per Month
Delivery Time :
10Days or More
Packaging Details :
Wooden Drum or Steel Drum
Conductor :
Aluminium
Insulation :
PE or XLPE
Cores No. :
5
Rated Voltage :
0.6/1KV
Application :
Overhead Power System
Structure :
3 Phase /1 Messenger /1 Street lighting
1KV AL/PVC Aluminium Aerial Bundled Cables With Street Lighting Conductors
Description
The aerial Bundled cables designed for overhead distribution lines have an insulated neutral messenger made of AAAC, which the insulated aluminium phase conductor are helically wound over it. Cables are rated at 0.6/1(1.2)kV and conform to IEC60502.
Construction
- Conductor:
a) Phase – The phase conductor shall be of H68 Condition aluminium conductor and compacted circular stranded.
b) Neutral or messenger – The Neutral or messenger conductor shall be of aluminium alloy conductor and compacted circular stranded c)Street Lighting- The street lighting conductors shall be of H68 condition aluminium conductor and compacted circular stranded..
- Insulation:
The phase, neutral conductors shall be extruded with polyethylene(PE) as insulation.
Schedule of technical particulars
Phase conductor | |||||||||
Nominal cross-sectional area | mm² | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
Minimum number of wires | 6 | 6 | 6 | 12 | 15 | 15 | 30 | 30 | |
Nominal insulation thickness | mm | 1.2 | 1.2 | 1.4 | 1.4 | 1.6 | 1.6 | 1.8 | 2.0 |
Diameter of insulated core | mm | 8.5 | 9.5 | 11.2 | 13.0 | 15.1 | 16.6 | 18.4 | 20.6 |
Max. DC resistance at 20℃ | ohm/km | 1.20 | 0.868 | 0.641 | 0.443 | 0.320 | 0.253 | 0.206 | 0.164 |
Current rating at still wind, ambient | A | 84 | 104 | 129 | 167 | 209 | 246 | 283 | 332 |
temperature=30℃ | |||||||||
Conductor temperature=75℃ | |||||||||
Messenger conductor | |||||||||
Nominal cross-sectional area | mm² | 25 | 25 | 35 | 50 | 70 | 70 | 95 | 120 |
Minimum number of wires | 6 | 6 | 6 | 6 | 12 | 12 | 15 | 15 | |
Nominal insulation thickness | mm | 1.2 | 1.2 | 1.2 | 1.4 | 1.4 | 1.4 | 1.6 | 1.6 |
Diameter of insulated core | mm | 8.5 | 8.5 | 9.5 | 11.2 | 13.1 | 13.1 | 15.1 | 16.6 |
Max. DC resistance at 20℃ | ohm/km | 1.312 | 1.312 | 0.943 | 0.693 | 0.469 | 0.469 | 0.349 | 0.273 |
Calculated breaking load | kN | 6.4 | 6.4 | 8.9 | 12.1 | 18.0 | 18.0 | 24.2 | 30.8 |
Street lighting conductor | |||||||||
Nominal cross-sectional area | mm² | 25 | 25 | 35 | 50 | 70 | 70 | 95 | 120 |
Minimum number of wires | 6 | 6 | 6 | 6 | 12 | 12 | 15 | 15 | |
Nominal insulation thickness | mm | 1.2 | 1.2 | 1.2 | 1.4 | 1.4 | 1.4 | 1.6 | 1.6 |
Diameter of insulated core | mm | 8.5 | 8.5 | 9.5 | 11.2 | 13.1 | 13.1 | 15.1 | 16.6 |
Max. DC resistance at 20℃ | ohm/km | 1.312 | 1.312 | 0.943 | 0.693 | 0.469 | 0.469 | 0.349 | 0.273 |
Completed cable | |||||||||
Approx. overall diameter | mm | 23.2 | 25.6 | 30.0 | 34.9 | 40.6 | 44.1 | 49.2 | 54.9 |
Approx. weight of cable | kg/km | 470 | 560 | 740 | 980 | 1330 | 1580 | 1940 | 2410 |
Packing length | m/drum | 1000 | 1000 | 1000 | 1000 | 500 | 500 | 500 | 500 |
STANDARD NF C 33-209
NFA 2X
Phases | Neutral/Messenger | ||||||||||||
Distribution Lines | Pub. Lighting | ||||||||||||
Cable Type | Number of | Number of | Avarage | Resistance | Number of | Conductance | Avarage | Rated | Resistance | ||||
core | wire | diameter | at 20℃ | core | at 30℃ | diameter | Strength | at 20℃ | |||||
mm² | mm² | PCS | mm | ohm/km | mm² | A | mm | kN | ohm/km | ||||
2×16 | 2×16 | 7 | 4.6 | 1.91 | – | – | – | – | – | ||||
2×35 | 2×35 | 7 | 5.9 | 1.20 | – | – | – | – | – | ||||
2×35 | 2×35 | 7 | 6.9 | 0.868 | – | – | – | – | – | ||||
2×50 | 2×50 | 7 | 8.1 | 0.641 | – | – | – | – | – | ||||
4×16 | 4×16 | 7 | 4.6 | 1.91 | – | – | – | – | – | ||||
4×25 | 4×25 | 7 | 5.9 | 1.20 | – | – | – | – | – | ||||
4×35 | 4×35 | 7 | 6.9 | 0.868 | – | – | – | – | – | ||||
3×25+54.6 | 3×25 | 7 | 5.9 | 1.20 | – | – | 9.6 | 16.0 | 0.63 | ||||
3×25+1×16+54.6 | 3×25 | 7 | 5.9 | 1.20 | 1×16 | 60 | 9.6 | 16.0 | 0.63 | ||||
3×25+2×16+54.6 | 3×25 | 7 | 5.9 | 1.20 | 2×16 | 9.6 | 16.0 | 0.63 | |||||
3×35+54.6 | 3×35 | 7 | 6.9 | 0.868 | – | – | 9.6 | 16.0 | 0.63 | ||||
3×35+1×16+54.6 | 3×35 | 7 | 6.9 | 0.868 | 1×16 | 60 | 9.6 | 16.0 | 0.63 | ||||
3×35+2×16+54.6 | 3×35 | 7 | 6.9 | 0.868 | 2×16 | 9.6 | 16.0 | 0.63 | |||||
3×50+54.6 | 3×50 | 7 | 8.1 | 0.641 | – | – | 9.6 | 16.0 | 0.63 | ||||
3×50+1×16+54.6 | 3×50 | 7 | 8.1 | 0.641 | 1×16 | 60 | 9.6 | 16.0 | 0.63 | ||||
3×50+2×16+54.6 | 3×50 | 7 | 8.1 | 0.641 | 2×16 | 9.6 | 16.0 | 0.63 | |||||
3×70+54.6 | 3×70 | 12 | 9.7 | 0.443 | – | – | 9.6 | 16.0 | 0.63 | ||||
3×70+1×16+54.6 | 3×70 | 12 | 9.7 | 0.443 | 1×16 | 60 | 9.6 | 16.0 | 0.63 | ||||
3×70+2×16+54.6 | 3×70 | 12 | 9.7 | 0.443 | 2×16 | 9.6 | 16.0 | 0.63 | |||||
3×70+1×25+54.6 | 3×70 | 12 | 9.7 | 0.443 | 1×25 | 9.6 | 16.0 | 0.63 | |||||
3×70+2×25+54.6 | 3×70 | 12 | 9.7 | 0.443 | 2×25 | 9.6 | 16.0 | 0.50 | |||||
3×70+70 | 3×70 | 12 | 9.7 | 0.443 | – | – | 10.2 | 20.6 | 0.50 | ||||
3×70+1×16+70 | 3×70 | 12 | 9.7 | 0.443 | 1×16 | 60 | 10.2 | 20.6 | 0.50 | ||||
3×70+2×16+70 | 3×70 | 12 | 9.7 | 0.443 | 2×16 | 10.2 | 20.6 | 0.50 | |||||
3×95+70 | 3×95 | 12 | 11.5 | 0.320 | – | – | 10.2 | 20.6 | 0.50 | ||||
3×95+1×16+70 | 3×95 | 12 | 11.5 | 0.320 | 1×16 | 60 | 10.2 | 20.6 | 0.50 | ||||
3×95+2×16+70 | 3×95 | 12 | 11.5 | 0.320 | 2×16 | 10.2 | 20.6 | 0.50 | |||||
3×120+70 | 3×120 | 12 | 12.8 | 0.253 | – | – | 10.2 | 20.6 | 0.50 | ||||
3×120+1×16+70 | 3×120 | 19 | 12.8 | 0.253 | 1×16 | 10.2 | 20.6 | 0.50 | |||||
3×120+2×16+70 | 3×120 | 19 | 12.8 | 0.253 | 2×16 | 60 | 10.2 | 20.6 | 0.50 | ||||
3×150+70 | 3×150 | 19 | 14.5 | 0.206 | – | 10.2 | 20.6 | 0.50 | |||||
3×150+1×16+70 | 3×150 | 19 | 14.5 | 0.206 | 1×16 | – | 10.2 | 20.6 | 0.50 | ||||
3×150+2×16+70 | 3×150 | 19 | 14.5 | 0.206 | 2×16 | 60 | 10.2 | 20.6 | 0.50 | ||||
3×120+95 | 3×120 | 19 | 12.8 | 0.253 | – | 12.9 | 27.9 | 0.343 | |||||
3×120+1×16+95 | 3×120 | 19 | 12.8 | 0.253 | 1×16 | – | 12.9 | 27.9 | 0.343 | ||||
3×120+2×16+95 | 3×120 | 19 | 12.8 | 0.253 | 2×16 | 60 | 12.9 | 27.9 | 0.343 | ||||
3×150+95 | 3×150 | 19 | 14.5 | 0.206 | – | 12.9 | 27.9 | 0.343 | |||||
3×150+1×16+95 | 3×150 | 19 | 14.5 | 0.206 | 1×16 | – | 12.9 | 27.9 | 0.343 | ||||
3×150+2×16+95 | 3×150 | 19 | 14.5 | 0.206 | 2×16 | 60 | 12.9 | 27.9 | 0.343 |
We are China Aluminium Aerial Bundled Cables manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: aerial bunched cables, Aerial Bundled Cable, aerial electrical cable