Al / Xlpe ( Pe ) Insulated Aerial Bunched Aerial Power Cable Standard Ts 11654 Aertor
Al / Xlpe ( Pe ) Insulated Aerial Bunched Aerial Power Cable Standard Ts 11654 Aertor image
Brand Name :
SHANCABLE
Model Number :
ABC-AAAC/XLPE
Certification :
TS 11654 AER
Place of Origin :
China
MOQ :
500m
Price :
0.19-10.99USD/m
Payment Terms :
L/C, D/A, D/P, T/T
Supply Ability :
1000km per Month
Delivery Time :
15 Days
Packaging Details :
Wooden Drum/ Steel Drum
Phase Conductor :
Aluminium
Insulation :
PE Or PVC
Rated Voltage :
0.6/1KV
Application :
Overhead Power Transmission Lines
Neutral Conductor :
Aluminium Alloy
Cors No. :
2,3,4,5,6
0.6/1(1.2)kV AL/XLPE(PE) Insulated
Aerial Bundled Cables with Street Lighting Conductor
Description:3 Phase conductors + 1 Messenger conductor + 1 Street lighting conductor
The aerial Bundled cables designed for overhead distribution lines have an insulated neutral messenger made of AAAC, which the insulated aluminium phase conductor are helically wound over it. Cables are rated at 0.6/1(1.2)kV and conform to IEC60502.
Construction
- Conductor:
a)Phase – The phase conductor shall be of H68 Condition aluminium conductor and compacted circular stranded.
b)Neutral or messenger – The Neutral or messenger conductor shall be of aluminium alloy conductor and compacted circular stranded c)Street Lighting- The street lighting conductors shall be of H68 condition aluminium conductor and compacted circular stranded..
- Insulation:
The phase, neutral conductors shall be extruded with polyethylene(PE) as insulation.
STANDARD TS 11654
AER
Insulated Wires | Porter | Completed cable | |||||||||||||
Number of | Main Distribution Line | Str. Lighting | |||||||||||||
Conductor Cross | Number | Number of | Diameter of | Resistance | Current | Number | Current | Diameter of | Min. Tensile | Resistance | Approx. | Approximate | |||
Section | &Cross- | wire | Wires | at 20℃ | Carrying | &Cross- | Carrying | Neutral/Mes | Strenght | at 20℃ | Average | weight | |||
section | Capacity at | section | Capacity at | senger Wire | Limite | Diameter | |||||||||
30℃ | 30℃ | ||||||||||||||
mm² | mm² | PCS | mm | ohm/km | A | mm² | A | mm | kN | ohm/km | mm | kg/km | |||
1×16+25 | 1×16 | 1 | 4.4 | 1.91 | 75 | – | – | 5.9 | 7.4 | 1.380 | 15 | 140 | |||
1×25+35 | 1×25 | 7 | 5.9 | 1.20 | 100 | – | – | 6.9 | 10.3 | 0.986 | 17 | 200 | |||
1×35+50 | 1×35 | 7 | 6.9 | 0.868 | 125 | – | – | 8.1 | 14.2 | 0.720 | 20 | 275 | |||
3×16+25 | 3×16 | 7 | 4.4 | 1.91 | 70 | – | – | 5.9 | 7.4 | 1.380 | 22 | 275 | |||
3×25+35 | 3×25 | 7 | 5.9 | 1.20 | 90 | – | – | 6.9 | 10.3 | 0.986 | 26 | 400 | |||
3×35+50 | 3×35 | 7 | 6.9 | 0.868 | 115 | – | – | 8.1 | 14.2 | 0.720 | 30 | 575 | |||
3×50+70 | 3×50 | 7 | 8.1 | 0.641 | 140 | – | – | 9.6 | 20.6 | 0.493 | 35 | 750 | |||
3×70+95 | 3×70 | 7 | 9.6 | 0.443 | 180 | – | – | 11.4 | 27.9 | 0.363 | 41 | 1050 | |||
3×120+95 | 3×120 | 19 | 12.8 | 0.253 | 250 | – | – | 11.4 | 27.9 | 0.363 | 47 | 1550 | |||
4×16+25 | 4×16 | 1 | 4.4 | 1.91 | 70 | – | – | 5.9 | 7.4 | 1.380 | 24 | 375 | |||
4×25+35 | 4×25 | 7 | 5.9 | 0.868 | 90 | – | – | 6.9 | 10.3 | 0.986 | 28 | 550 | |||
4×35+50 | 4×35 | 7 | 6.9 | 0.868 | 115 | – | – | 8.1 | 14.2 | 0.720 | 32 | 750 | |||
4×50+70 | 4×50 | 7 | 8.1 | 0.641 | 140 | – | – | 9.6 | 20.6 | 0.493 | 38 | 1000 | |||
4×70+95 | 4×70 | 7 | 9.6 | 0.443 | 180 | – | – | 11.4 | 27.9 | 0.363 | 45 | 1350 | |||
1×16+25 | – | – | – | – | – | 1×16 | 75 | 5.9 | 7.4 | 1.380 | 14 | 140 | |||
1×16+1×16+25 | 1×16 | 1 | 4.4 | 1.91 | 70 | 1×16 | 60 | 5.9 | 7.4 | 1.380 | 15 | 225 | |||
3×16+1×16+25 | 3×16 | 1 | 4.4 | 1.91 | 60 | 1×16 | 60 | 5.9 | 7.4 | 1.380 | 22 | 350 | |||
3×25+1×16+35 | 3×25 | 7 | 5.9 | 1.20 | 80 | 1×16 | 60 | 6.9 | 10.3 | 0.986 | 26 | 475 | |||
3×35+1×16+35 | 3×35 | 7 | 6.9 | 0.868 | 95 | 1×16 | 60 | 8.1 | 14.2 | 0.720 | 30 | 625 | |||
3×50+1×16+70 | 3×50 | 7 | 8.1 | 0.641 | 120 | 1×16 | 60 | 9.6 | 20.6 | 0.493 | 35 | 800 | |||
3×70+1×16+95 | 3×70 | 7 | 9.6 | 0.443 | 150 | 1×16 | 60 | 11.4 | 27.9 | 0.363 | 41 | 1100 | |||
4×16+1×16+25 | 4×16 | 1 | 4.4 | 1.91 | 60 | 1×16 | 60 | 5.9 | 7.4 | 1.380 | 25 | 450 | |||
4×25+1×16+35 | 4×25 | 7 | 5.9 | 1.20 | 80 | 1×16 | 60 | 6.9 | 10.3 | 0.986 | 30 | 610 | |||
4×35+1×16+50 | 4×35 | 7 | 6.9 | 0.868 | 95 | 1×16 | 60 | 8.1 | 14.2 | 0.720 | 34 | 800 | |||
4×50+1×16+70 | 4×50 | 7 | 8.1 | 0.641 | 120 | 1×16 | 60 | 9.6 | 20.6 | 0.493 | 40 | 1060 | |||
4×70+1×16+95 | 4×70 | 7 | 9.6 | 0.443 | 180 | 1×16 | 60 | 11.4 | 27.9 | 0.363 | 47 | 1420 |
We are China Al / Xlpe ( Pe ) Insulated Aerial Bunched Aerial Power Cable Standard Ts 11654 Aertor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: aerial bunched cables, Aerial Bundled Cable, aerial electrical cable