AL / XLPE Insulation Cable Aerial Bunch Cable For Overhead Distribution Lines
AL / XLPE Insulation Cable Aerial Bunch Cable For Overhead Distribution Lines image
Brand Name :
HOLD-ONE
Certification :
CE ROHS KEMA
Place of Origin :
China
MOQ :
1000m
Price :
0.19-10.99USD/M
Payment Terms :
L/C, T/T
Supply Ability :
500km per Month
Delivery Time :
15 Days
Packaging Details :
Wooden Drum/ Steel Drum
Rated Voltage :
0.6/1kV
Installation Degree :
-20℃-90℃
Main Usage :
Overhead fixed layout and wire conducting
Sample :
20cm free of charge
Package :
Wooden drum
Type :
Insulated
AL/XLPE(PE) Insulated ABC Cable 0.6/1 kV (BS 7870-5) for Overhead Distribution Lines
Description
The aerial Bundled cables designed for overhead distribution lines have an insulated neutral messenger made of AAAC, which the insulated aluminium phase
conductor are helically wound over it. Cables are rated at 0.6/1(1.2)kV and conform to IEC60502.
Construction
1 Conductor:
a)Phase – The phase conductor shall be of H68 Condition aluminium conductor and compacted circular stranded.
b)Neutral or messenger – The Neutral or messenger conductor shall be of aluminium alloy conductor and compacted circular stranded
c)Street Lighting- The street lighting conductors shall be of H68 condition aluminium conductor and compacted circular stranded..
2 Insulation:The phase, neutral conductors shall be extruded with polyethylene(PE) as insulation.
Schedule of technical particulars
Phase conductor | |||||||||
Nominal cross-sectional area | mm² | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
Minimum number of wires | 6 | 6 | 6 | 12 | 15 | 15 | 30 | 30 | |
Nominal insulation thickness | mm | 1.2 | 1.2 | 1.4 | 1.4 | 1.6 | 1.6 | 1.8 | 2.0 |
Diameter of insulated core | mm | 8.5 | 9.5 | 11.2 | 13.0 | 15.1 | 16.6 | 18.4 | 20.6 |
Max. DC resistance at 20℃ | ohm/km | 1.20 | 0.868 | 0.641 | 0.443 | 0.320 | 0.253 | 0.206 | 0.164 |
Current rating at still wind, ambient | A | 84 | 104 | 129 | 167 | 209 | 246 | 283 | 332 |
temperature=30℃ | |||||||||
Conductor temperature=75℃ | |||||||||
Messenger conductor | |||||||||
Nominal cross-sectional area | mm² | 25 | 25 | 35 | 50 | 70 | 70 | 95 | 120 |
Minimum number of wires | 6 | 6 | 6 | 6 | 12 | 12 | 15 | 15 | |
Nominal insulation thickness | mm | 1.2 | 1.2 | 1.2 | 1.4 | 1.4 | 1.4 | 1.6 | 1.6 |
Diameter of insulated core | mm | 8.5 | 8.5 | 9.5 | 11.2 | 13.1 | 13.1 | 15.1 | 16.6 |
Max. DC resistance at 20℃ | ohm/km | 1.312 | 1.312 | 0.943 | 0.693 | 0.469 | 0.469 | 0.349 | 0.273 |
Calculated breaking load | kN | 6.4 | 6.4 | 8.9 | 12.1 | 18.0 | 18.0 | 24.2 | 30.8 |
Street lighting conductor | |||||||||
Nominal cross-sectional area | mm² | 25 | 25 | 35 | 50 | 70 | 70 | 95 | 120 |
Minimum number of wires | 6 | 6 | 6 | 6 | 12 | 12 | 15 | 15 | |
Nominal insulation thickness | mm | 1.2 | 1.2 | 1.2 | 1.4 | 1.4 | 1.4 | 1.6 | 1.6 |
Diameter of insulated core | mm | 8.5 | 8.5 | 9.5 | 11.2 | 13.1 | 13.1 | 15.1 | 16.6 |
Max. DC resistance at 20℃ | ohm/km | 1.312 | 1.312 | 0.943 | 0.693 | 0.469 | 0.469 | 0.349 | 0.273 |
Completed cable | |||||||||
Approx. overall diameter | mm | 23.2 | 25.6 | 30.0 | 34.9 | 40.6 | 44.1 | 49.2 | 54.9 |
Approx. weight of cable | kg/km | 470 | 560 | 740 | 980 | 1330 | 1580 | 1940 | 2410 |
Packing length | m/drum | 1000 | 1000 | 1000 | 1000 | 500 | 500 | 500 | 500 |
We are China AL / XLPE Insulation Cable Aerial Bunch Cable For Overhead Distribution Lines manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: ABC Power Cable, Aerial Bundled Cable, aerial electrical cable