ACSR Code 300 / 50 Bare Aluminum Power Cable Conductor Transmission Lines DIN 48204
ACSR Code 300 / 50 Bare Aluminum Power Cable Conductor Transmission Lines DIN 48204 image
Brand Name :
Zhenglan Cable
Model Number :
Overhead Bare Conductor ACSR 300/50mm2 Aluminum Conductor With Steel reinforced Cable
Certification :
3C; ISO 9001:2015, ISO 14001:2005, OHSAS 18001:2007
Place of Origin :
Henan, China
MOQ :
300 meters
Price :
0.1-100USD/m
Payment Terms :
L/C, T/T,, Western Union
Supply Ability :
15-30ton/day
Delivery Time :
15 days
Packaging Details :
Wooden drum, wood and steel drum,as customer’s request
Material :
AL&STEEL
Out Sheath Color :
None
Cable Drum Length :
Normal or Customized
characted :
Bare Conductor
Country of original :
Henan, China
Total Area :
15.15~1046
Package :
wooden drum/steel drum
Application :
overhead power transmission
Aluminum Conductor Steel Reinforced ACSR code 300/50 Bare Aluminum Conductor transmission lines DIN 48204
Application
ACSR conductors are widely used for electrical power transmission over long distances, since they are ideal for long overhead lines spans. They are also used as a messenger for supporting overhead electrical cables.
Bare Conductor Electrical Cable STANDARD
Basic design to BS 215-2 / BS EN 50182 / IEC 61089 / ASTM B 232/B 232M / DIN 48204 / JIS C 3110 standards.
Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
Bare Conductor Electrical Cable CONSTRUCTION
ACSR conductors are formed by several wires of aluminium and galvanized steel, stranded in concentric layers. The wire or wires which form the core, are made of galvanized steel and the external layer or layers, are of aluminium. Galvanized steel core consist normally of 1, 7 or 19 wires. The diameters of steel and aluminium wires can be the same, or different.
By varying the relative proportions of aluminium and steel, the required characteristics for any particular application can be reached. A higher U. T. S. Can be obtained, by increasing steel content, and a higher current carrying capacity by increasing aluminium content.
ELECTRICAL PROPERTIES
density@20ºC | Aluminium: 2.703 kg/dm |
Galvanised Steel: 7.80 kg/dm | |
Temperature Coefficient@20°C | Aluminium: 0.00403 (°C) |
resistivity@20°C | Aluminium: Should not exceed 0.028264 |
linear Expansivity |
Aluminium: 23 x10 (°C) |
Galvanised Steel: 11.5 x10 (1/°C) |
SERVICE CONDITIONS
Ambient Temperature | -5°C – 50°C |
Wind Pressure | 80 – 130kg/m |
Seismic Acceleration | 0.12 – 0.05g |
Isokeraunic level | 10 – 18 |
relative Humidity | 5 – 100% |
TECHNICAL DATA
Numbers of Wires | Modules of Elasticity | Coeficient of linear Expansion | |||
AL | STEEL | Kg/mm2 | Lb/in2 | 1/Cº | 1/Fº |
6 | 1 | 81 | 11.5 x106 | 19.1 x10-6 | 10.6 x10-6 |
6 | 7 | 77 | 11.0 x106 | 19.8 x10-6 | 11.0 x10-6 |
12 | 7 | 107 | 15.2 x106 | 15.3 x10-6 | 8.5 x10-6 |
18 | 1 | 67 | 9.5 x106 | 21.2 x10-6 | 11.8 x10-6 |
24 | 7 | 74 | 10.5 x106 | 19.6 x10-6 | 10.9 x10-6 |
26 | 7 | 77 | 10.9 x106 | 18.9 x10-6 | 10.5 x10-6 |
28 | 7 | 79 | 11.2 x106 | 18.4 x10-6 | 10.2 x10-6 |
30 | 7 | 82 | 11.6 x106 | 17.8 x10-6 | 9.9 x10-6 |
30 | 19 | 80 | 11.4 x106 | 18.0 x10-6 | 10.0 x10-6 |
32 | 19 | 82 | 11.7 x106 | 17.5 x10-6 | 9.7 x10-6 |
54 | 7 | 70 | 9.9 x106 | 19.3 x10-6 | 10.7 x10-6 |
54 | 19 | 68 | 9.7 x106 | 19.4 x10-6 | 10.8 x10-6 |
ACSR Conductor – DIN 48204 Standard
Area | Standing and wire diameter | Overall diameter | Nominal breaking load | Maximum resistance at 20°C | Current Rating | |||||
Nominal. | Actual | Total. | ||||||||
Al/Steel– | Al | Steel | Total | Aluminum | Steel | |||||
mm2 | mm2 | mm2 | mm | mm | mm | kg/km | daN | Ω/km | A | |
16/2.5 | 15.1515 | 2.22 | 18.1818 | 6/1.80 | 1/1.80 | 5.55 | 62 | 595 | 2.22222 | 105 |
25/4.0 | 24.2424 | 4.44 | 28.2828 | 6/2.25 | 1/2.5 | 7.77 | 97 | 920 | 1.11111 | 140 |
35/6.0 | 34.3434 | 6.66 | 40.4040 | 6/2.70 | 1/2.70 | 8.88 | 140 | 1265 | 1.11111 | 170 |
44/32.0 | 44.4444 | 32.3232 | 76.7676 | 14/2.00 | 7/2.40 | 11.1111 | 372 | 4500 | 1.11111 | 220 |
50/8.0 | 48.4848 | 8.88 | 56.5656 | 6/3.20 | 1/3.20 | 10.1010 | 196 | 1710 | 1.11111 | 210 |
50/30 | 51.5151 | 30.3030 | 81.8181 | 12/2.33 | 7/2.33 | 12.1212 | 378 | 4380 | 1.11111 | 223 |
70/12 | 70.7070 | 11.1111 | 81.8181 | 26/1.85 | 7/1.44 | 12.1212 | 284 | 2680 | 0.00000 | 290 |
95/15 | 94.9494 | 15.1515 | 110.110110 | 26/2.15 | 7/1.67 | 14.1414 | 383 | 3575 | 0.00000 | 350 |
95/55 | 96.9696 | 56.5656 | 153.153153 | 12/3.20 | 7/3.20 | 16.1616 | 712 | 7935 | 0.00000 | 352 |
105/75 | 106.106106 | 76.7676 | 182.182182 | 14/3.10 | 9/2.25 | 18.1818 | 891 | 10845 | 0.00000 | 385 |
120/20 | 121.121121 | 20.2020 | 141.141141 | 26/2.44 | 7/1.90 | 16.1616 | 494 | 4565 | 0.00000 | 410 |
120/70 | 122.122122 | 71.7171 | 193.193193 | 12/3.60 | 7/3.60 | 18.1818 | 90 | 10000 | 0.00000 | 410 |
125/30 | 128.128128 | 30.3030 | 158.158158 | 30/2.33 | 7/2.33 | 16.1616 | 591 | 5760 | 0.00000 | 425 |
150/25 | 149.149149 | 24.2424 | 173.173173 | 26/2.70 | 7/2.10 | 17.1717 | 605 | 5525 | 0.00000 | 470 |
170/40 | 172.172172 | 40.4040 | 212.212212 | 30/2.70 | 7/2.70 | 19.1919 | 794 | 7675 | 0.00000 | 520 |
185/30 | 184.184184 | 30.3030 | 214.214214 | 26/3.00 | 7/2.33 | 19.1919 | 746 | 6620 | 0.00000 | 535 |
210/35 | 209.209209 | 34.3434 | 243.243243 | 26/3.20 | 7/2.49 | 20.2020 | 850 | 7490 | 0.00000 | 590 |
210/50 | 212.212212 | 50.5050 | 262.262262 | 30/3.00 | 7/3.00 | 21.2121 | 981 | 9390 | 0.00000 | 610 |
230/30 | 231.231231 | 30.3030 | 261.261261 | 24/3.50 | 7/2.33 | 21.2121 | 877 | 7310 | 0.00000 | 630 |
240/40 | 243.243243 | 40.4040 | 282.282282 | 26/3.45 | 7/2.68 | 22.2222 | 987 | 8640 | 0.00000 | 645 |
265/35 | 264.264264 | 34.3434 | 298.298298 | 24/3.74 | 7/2.49 | 22.2222 | 1002 | 8305 | 0.00000 | 680 |
300/50 | 304.304304 | 50.5050 | 354.354354 | 26/3.86 | 7/3.00 | 24.2424 | 1236 | 10700 | 0.00000 | 740 |
Why you choose us?
- OEM/ODM services provided;
- Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted;
- Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007;
- Registered capital of $30 million and factory covers an area of 60,000㎡;
- Advanced test equipment and procedures, 100% inspection before factory;
- Enough stocks and the higest efficient shipping time guarranteed;
- Professional pre-sales and after-sales services provided
We are China ACSR Code 300 / 50 Bare Aluminum Power Cable Conductor Transmission Lines DIN 48204 manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: Aluminum Power Cable, Bare Aluminum Power Cable Conductor, Code 300/50 Bare Aluminum Power Cable, DIN 48204 Aluminum Power CableFAST AND RELIABLE SERVICE FOR YOUR PROJECT
Contact our trained experts today to find your perfect power solution.
ASK A QUESTION© 2020 Galaxy Electric Country Code Sitemap Cable Cable Drum