ACSR AAC Aerial Bundle Cables LV Power Cable Overhead Cable Conductor
ACSR AAC Aerial Bundle Cables LV Power Cable Overhead Cable Conductor image
ACSR AAC Aerial Bundle Cables LV Power Cable Overhead Cable Conductor
1. Application
Aerial Bunch Cables are basically a compromise construction between Power cables and Overhead conductors. It is preferred to use of ABC cables instead of uninsulated conductors at low voltage networks. ABC cables are especially used at areas where the cost of underground networks is expensive and also for electrification of rural areas like villages. Bundles can include one or two additional conductors for public lighting and control pair.
2. Specification of Triplex Low Voltage Power Cable
Cable meets or exceeds the following ASTM specifications:
· B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
· B-231 Aluminum Conductors, Concentric-Lay-Stranded.
· B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
· B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
· B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire
3. Conductor:
Phase Conductor | Bare Neutral Messenger |
AAC | AAC |
ACSR | |
Alloy |
4. Service Drop Cable Meets or Exceeds the Following Specifications:
1). Aluminum Wire,1350-H19 for Electrical Purposes;
2). Aluminum Conductors,Concentric-Lay-Stranded;
3). Aluminum Conductor,Concentric-Lay-Stranded,Coated Steel Reinforced(ACSR);
4). Concentric-Lay-Stranded 6201-T81 Conductors;
5). Service drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474;
5. Cable's Characteristics:
1). Max.admissible long time operating to conductor:
PVC or PE insulated should not exceed 70℃,XLPE insulated should not exceed 90℃;
2). Installing temperature should not be below -20℃;
3). Admissible bending radius:
When overall-diameter(D)is less than 25mm,it should be not less than 4D;
When overall-diameter(D) is 25mm or more,it should be not less than 6D;
Triplex Service Drop
Code name | AWG or kcmil | Bare Neutral Messenger | Phase Conductor | Weight | Allowable Ampacities(A) | ||||
ACSR | Rated Strength lbs. | AAC | Insul.Thick.Mm | ||||||
No.&Dia.Mm | No.& Dia.Mm | No. & Dia.Mm | kg/km | XLPE | PE | ||||
Paludina | 2*6AWG+1*6AWG | 1*1.68 | 6*1.68 | 1190 | 1*4.11 | 1.14 | 166 | 85 | 70 |
Voluta | 2*6AWG+1*6AWG | 1*1.68 | 6*1.68 | 1190 | 7*1.56 | 1.14 | 170 | 85 | 70 |
Whelk | 2*4AWG+1*4AWG | 1*2.12 | 6*2.12 | 1860 | 1*5.19 | 1.14 | 251 | 115 | 90 |
Periwinkle | 2*4AWG+1*4AWG | 1*2.12 | 6*2.12 | 1860 | 7*1.96 | 1.14 | 255 | 115 | 90 |
Conch | 2*2AWG+1*2AWG | 1*2.67 | 6*2.67 | 2850 | 7*2.47 | 1.14 | 389 | 150 | 120 |
Neritina | 2*1/0AWG+1*1/0AWG | 1*3.37 | 6*3.37 | 4380 | 7*3.12 | 1.52 | 624 | 205 | 160 |
Cenia | 2*1/0AWG+1*1/0AWG | 1*3.37 | 6*3.37 | 4380 | 19*1.89 | 1.52 | 625 | 205 | 160 |
Duplex Service Drop
Code word | AWG or kcmil | Bare Neutral Messenger | Phase Conductor | Weight | Allowable Ampacities(A) | |||
ALLOY | Rated Strength libs. | A AC | Insul.Thick.Mm | |||||
Number & Dia.Mm | Number&Dia.Mm | kg/km | XLPE | PE | ||||
Chihuahua | 1*6AWG+1*30.58 | 7*1.68 | 1110 | 1*4.11 | 1.14 | 98 | 85 | 70 |
Vizsla | 1*6AWG+1*30.58 | 7*1.68 | 1110 | 7*1.56 | 1.14 | 100 | 85 | 70 |
Harrier | 1*4AWG+1*48.69 | 7*2.12 | 1760 | 1*5.19 | 1.14 | 149 | 115 | 90 |
Whippet | 1*4AWG+1*48.69 | 7*2.12 | 1760 | 7*1.96 | 1.14 | 151 | 115 | 90 |
Schnauzer | 1*2AWG+1*77.47 | 7*2.67 | 2800 | 7*2.47 | 1.14 | 231 | 150 | 120 |
Heeler | 1*1/0AWG+1*123.3 | 7*3.37 | 4460 | 19*1.89 | 1.52 | 372 | 205 | 160 |
We are China ACSR AAC Aerial Bundle Cables LV Power Cable Overhead Cable Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: AAC low voltage aerial bundled cable, ACSR lv power cable, LV Power Cable, Overhead lv power cable