AAC Coreopsis 61/4.1mm All Alumibum Conductor 806sqmm ASTM B231/B231M
AAC Coreopsis 61/4.1mm All Alumibum Conductor 806sqmm ASTM B231/B231M image
Brand Name :
Zhenglan Cable
Model Number :
bare aluminum conductor AAC coreopsis(61/4.1mm) all alumibum conductor 806sqmmASTM B231/B231M
Certification :
3C,ISO 9001:2015,ISO 14001:2005
Place of Origin :
Henan, China
MOQ :
Negotiable
Price :
Negotiable
Payment Terms :
L/C, T/T, Western Union
Supply Ability :
20,000 ton/year
Delivery Time :
15-30 days
Packaging Details :
Fully wooden drum, steel wooden drum, fully steel drum or customized
Material :
aluminium
Size :
1013sqmm
Quality :
100% IEC Standards test
Standard :
ASTM-B231/231M
Brand :
Zhenglan Cable
Stranding :
91/3.77mm
Bare aluminum conductor AAC coreopsis(61/4.1mm) all alumibum conductor 806sqmmASTM B231/B231M
AAAC is mainly used as bare overhead transmission cable and as primary and secondary distribution cable. It is also suitable for laying across basins, rivers and valleys where special geographical teatures exist.
Place of Origin: Henan,China (Mainland)
Brand Name: ZHENGLAN
Insulation Material: none
Application: Overhead
Conductor Material: Aluminum, aluminum alloy
Jacket: none
Product name: Aluminum Conductor
Quality: 100% test
Size: AWG,mm2 or customized
Rated Voltage: 35kv/110kv/220kv/500kv
Packaging Details: fully wooden drum, steel wooden drum, fully steel drum or customized
STANDARD
Basic design to BS 215-1 / BS EN 50182 / IEC 61089 / ASTM B 231/B 231M / DIN 48201-5 standards
bare aluminum conductor AAC coreopsis(61/4.1mm) all alumibum conductor 806sqmmASTM B231/B231M Application:Concentric lay stranded Aluminium Conductor (AAC) is made up of one or more strands of hard drawn 1350 aluminum alloy. These conductors are used in low, medium and high voltage overhead lines. AAC has seen extensive use in urban areas where spans are usually short but high conductivity us required. The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas. Because of its relatively poor strength to weight ratio, AAC had limited use in transmission lines and rural distribution because of long spans utilized. All aluminium conductors are made up of one or more strands of aluminium wire dep.
bare aluminum conductor AAC coreopsis(61/4.1mm) all alumibum conductor 806sqmmASTM B231/B231M technical data sheet
Code | Nominal Area | Stranding | Overall Diameter | Weight | Rated Strength | Electrical Resistance | Current Rating* | |
AWG&MCM | mm2 | No.×mm | mm | kg/km | KN | Ω/Km | A | |
Peachbell | 6 | 13.3 | 7/1.56 | 4.68 | 36.6 | 2.53 | 2.1477 | 75 |
Rose | 4 | 21.1 | 7/1.96 | 5.88 | 58.2 | 3.91 | 1.3606 | 99 |
Iris | 2 | 33.6 | 7/2.47 | 7.41 | 92.6 | 5.99 | 0.8567 | 132 |
Pansy | 1 | 42.4 | 7/2.78 | 8.34 | 116.6 | 7.3 | 0.6763 | 153 |
Poppy | 1/0.0 | 53.5 | 7/3.12 | 9.36 | 147.2 | 8.84 | 0.5369 | 176 |
Aster | 2/0.0 | 67.4 | 7/3.50 | 10.5 | 185.7 | 11.1 | 0.4267 | 203 |
Phlox | 3/0.0 | 85 | 7/3.93 | 11.79 | 233.9 | 13.5 | 0.3384 | 234 |
Oxlip | 4/0.0 | 107.2 | 7/4.42 | 13.26 | 295.2 | 17 | 0.2675 | 270 |
Valerian | 250 | 126.7 | 19/2.91 | 14.55 | 348.6 | 20.7 | 0.2274 | 299 |
Sneezewort | 250 | 126.7 | 7/4.80 | 14.4 | 348.8 | 20.1 | 0.2269 | 299 |
Laurel | 266.8 | 135.2 | 19/3.01 | 15.05 | 372.2 | 22.1 | 0.2125 | 312 |
Daisy | 266.8 | 135.2 | 7/4.96 | 14.88 | 372.3 | 21.4 | 0.2125 | 311 |
Peony | 300 | 152 | 19/3.19 | 15.95 | 418.3 | 24.3 | 0.1892 | 335 |
Tulip | 336.4 | 170.5 | 19/3.38 | 16.9 | 469.5 | 27.3 | 0.1686 | 359 |
Daffodil | 350 | 177.3 | 19/3.45 | 17.25 | 487.9 | 28.4 | 0.1618 | 369 |
Canna | 397.5 | 201.4 | 19/3.67 | 18.35 | 554.9 | 31.6 | 0.143 | 397 |
Goldentuft | 450 | 228 | 19/3.91 | 19.55 | 627.6 | 35 | 0.126 | 429 |
Syringa | 477 | 241.7 | 37/2.88 | 20.16 | 664.8 | 38.6 | 0.1192 | 444 |
Cosmos | 477 | 241.7 | 19/4.02 | 20.1 | 664.8 | 37 | 0.1192 | 444 |
Hyacinth | 500 | 253.3 | 37/2.95 | 20.65 | 696.8 | 40.5 | 0.1136 | 458 |
Zinnia | 500 | 253.3 | 19/4.12 | 20.6 | 697.1 | 38.9 | 0.1134 | 458 |
Dahlia | 556.5 | 282 | 19/4.35 | 21.75 | 775.8 | 43.3 | 0.1018 | 489 |
Mistletoe | 556.5 | 282 | 37/3.12 | 21.84 | 775.7 | 44.3 | 0.1016 | 490 |
Meadowsweet | 600 | 304 | 37/3.23 | 22.61 | 836.3 | 47.5 | 0.0948 | 511 |
Orchid | 636 | 322.3 | 37/3.33 | 23.31 | 886.9 | 50.4 | 0.0892 | 530 |
Heuchera | 650 | 329.4 | 37/3.37 | 23.59 | 907.4 | 51.7 | 0.0871 | 538 |
Code | Nominal Area | Stranding | Overall Diameter | Weight | Rated Strength | Electrical Resistance | Current Rating* | |
AWG&MCM | mm2 | No.×mm | mm | kg/km | KN | Ω/Km | A | |
Flag | 700 | 354.7 | 61/2.72 | 24.48 | 975.8 | 57.1 | 0.0811 | 561 |
Varbena | 700 | 354.7 | 37/3.49 | 24.43 | 975.7 | 55.4 | 0.0812 | 561 |
Nasturtium | 715.5 | 362.6 | 61/2.75 | 24.75 | 998.5 | 58.4 | 0.0793 | 569 |
Violet | 715.5 | 362.6 | 37/3.53 | 24.71 | 998.5 | 56.7 | 0.0794 | 568 |
Cattail | 750 | 380 | 61/2.82 | 25.38 | 1046 | 60.3 | 0.0754 | 587 |
Petunia | 750 | 380 | 37/3.62 | 25.34 | 1046 | 58.6 | 0.0755 | 586 |
Lilac | 795 | 402.8 | 61/2.90 | 26.1 | 1110 | 63.8 | 0.0713 | 607 |
Arbutus | 795 | 402.8 | 37/3.72 | 26.04 | 1109 | 61.8 | 0.0715 | 605 |
Snapdragon | 900 | 456 | 61/3.09 | 27.81 | 1256 | 70.8 | 0.0628 | 654 |
Cockscomb | 900 | 456 | 37/3.96 | 27.72 | 1256 | 68.4 | 0.0631 | 652 |
Goldenrod | 954 | 483.4 | 61/3.18 | 28.62 | 1331 | 75 | 0.0593 | 677 |
Magnolia | 954 | 483.4 | 37/4.08 | 28.56 | 1331 | 72.6 | 0.0594 | 676 |
Camellia | 1000 | 506.7 | 61/3.25 | 29.25 | 1394 | 78.3 | 0.0568 | 695 |
Hawkweed | 1000 | 506.7 | 37/4.18 | 29.26 | 1395 | 76.2 | 0.0566 | 696 |
Larkspur | 1033.5 | 523.7 | 61/3.31 | 29.79 | 1442 | 81.3 | 0.0547 | 710 |
Bluebell | 1033.5 | 523.7 | 37/4.25 | 29.75 | 1441 | 78.8 | 0.0547 | 710 |
Marigold | 1113 | 564 | 61/3.43 | 30.87 | 1553 | 87.3 | 0.051 | 740 |
Hawthorn | 1192.5 | 604.2 | 61/3.55 | 31.95 | 1662 | 93.5 | 0.0476 | 771 |
Narsissus | 1272 | 644.5 | 61/3.67 | 33.03 | 1774 | 98.1 | 0.0445 | 802 |
Columbine | 1351 | 694.8 | 61/3.78 | 34.02 | 1884 | 104 | 0.042 | 829 |
Carnation | 1431 | 725.1 | 61/3.89 | 35.01 | 1997 | 108 | 0.0396 | 858 |
Gladiolus | 1510.5 | 765.4 | 61/4.00 | 36 | 2108 | 114 | 0.0375 | 885 |
Coreopsis | 1590 | 805.7 | 61/4.10 | 36.9 | 2216 | 120 | 0.0357 | 911 |
Jassamine | 1750 | 886.7 | 61/4.30 | 38.7 | 2442 | 132 | 0.0324 | 962 |
Cowslip* | 2000 | 1013 | 91/3.77 | 41.47 | 2787 | 153 | 0.0286 | 1032 |
Sagebrush* | 2250 | 1140 | 91/3.99 | 43.89 | 3166 | 167 | 0.0255 | 1099 |
Lupine* | 2500 | 1267 | 91/4.21 | 46.31 | 3519 | 186 | 0.0229 | 1163 |
Bitterrot* | 2750 | 1393 | 91/4.42 | 48.62 | 3872 | 205 | 0.0208 | 1223 |
Trillium* | 3000 | 1520 | 127/3.90 | 50.7 | 4226 | 223 | 0.0193 | 1271 |
Bluebonnet* | 3500 | 1773 | 127/4.22 | 54.86 | 4977 | 261 | 0.0165 | 1373 |
bare aluminum conductor AAC coreopsis(61/4.1mm) all alumibum conductor 806sqmmASTM B231/B231M packing info
The reason you choose us:
- We are profeesional cable supplier for more than 10 years.
- Not only provide you good-quality products,but also service you well.
- We have high work efficency.
If you are interested, please do not hesitate to contact us.Any inquiry will be welcomed.
We are China AAC Coreopsis 61/4.1mm All Alumibum Conductor 806sqmm ASTM B231/B231M manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: 61/4.1mm AAC Coreopsis, 61/4.1mm All Alumibum Conductor, 806sqmm All Alumibum Conductor, Bare Aluminum Conductor