XLPE PVC Insulation 185 Sqmm 240 Sqmm LV Power Cable
XLPE PVC Insulation 185 Sqmm 240 Sqmm LV Power Cable image
Brand Name :
Sanwu
Model Number :
Al power cable -04
Certification :
IS09001, IS014001,OHSAS18001
Place of Origin :
Luoyang,China
MOQ :
10000meters
Price :
Negotiable
Supply Ability :
1000km per month
Delivery Time :
2-6weeks
Packaging Details :
Wooden drum 1100*400*700*900mm
Conductor Material :
Aluminum
Insulation Material :
XLPE/PVC
Jacket :
XLPE, PVC or PE
Application :
Industrial, Construction
Color :
As per standard
Rated Voltage :
0.6/1kV
185 sqmm 240 sqmm XLPE Insulated PVC Sheathed Aluminum Low Voltage Power Cable
Application:
This product is suitable for power transmission and distribution line of rated voltage (U0/U) 0.6/1.0KV line.
Technical Parameter:
When the cable is running normally, the Maximum temperature of conductor is 90℃; and is 250 ℃ when the short circuit (Max. last 5s) happens.
The ambient temperature of installation shall not lower than 0 degrees.
Minimum bending radius is 12 D (“D” refers to cable diameter)
- Complete Cable:
- One phase conductor, and one neutral conductor are insulated with Extruded Cross-Linked Polyethylene (XLPE) and jacketed with Extruded High-Density Cross-Linked Polyethylene (HDXLPE)
- Twisted cables form duplex assembly
- Manufactured and tested in accordance with ANSI/ICEA Standard S-81-570
- When specified, cable is produced in accordance with UL 854 and listed as a Type USE-2 cable
- Conductors:
- Class B compressed aluminum 1350-H19 meeting the requirements of ASTM B231 or B786
- Insulation & Jacket:
- Insulation is Extruded Black Cross-Linked Polyethylene (XLPE)
- Jacket is Extruded High-Density Cross-Linked Polyethylene and meets requirements of ASTM D1248, Type III
- The phase conductor is black, and the neutral conductor is black identified by three extruded yellow stripes.
Jacketed Aluminum Duplex Conductor Underground Power Cable Features and Benefits:
- Insulation/Jacket system provide high degree of protection against insulation damage
- For NEC-complying applications, the maximum conductor operating temp is 90°C in wet or dry locations
- Also suitable for non-code-complying installations with a temperature of 90°C in wet or dry locations in accordance with ICEA specifications
Jacketed Aluminum Duplex Conductor Underground Power Cable Applications:
- Intended for use in underground systems operated at 600 volts or less.
Jacketed Aluminum Duplex Conductor Underground Power Cable Options:
- Aluminum 1350-H16 conductor
- Copper conductors
- Other neutral identification methods
- CDC Combined Duct & Cable
- Reeless Package
- PE Insulated/HDPE Jacketed rated 75°C, Type UD-S
- Type USE-2 per UL 44
Single Core Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
1*1.5 | 0.7 | 1.5 | 6 | 53 | 53 | ≤12.1 | ≤12.1 | 3.5 | 26 | 26 | 33 | 32 |
1*2.5 | 0.7 | 1.5 | 6 | 68 | ≤7.41 | 3.5 | 34 | 43 | ||||
1*4 | 0.7 | 1.5 | 7 | 87 | 64 | ≤4.61 | ≤7.41 | 3.5 | 44 | 35 | 56 | 42 |
1*6 | 0.7 | 1.5 | 7 | 110 | 73 | ≤3.08 | ≤4.61 | 3.5 | 56 | 45 | 70 | 54 |
Two Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
2*2.5 | 0.7 | 1.8 | 11.8 | 151 | 118 | ≤7.41 | ≤12.1 | 3.5 | 26 | 20 | 35 | 27 |
2*4 | 0.7 | 1.8 | 12.7 | 198 | 146 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
2*6 | 0.7 | 1.8 | 13.7 | 250 | 173 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
2*10 | 0.7 | 1.8 | 16.3 | 374 | 245 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Three Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
3×1.5 | 0.7 | 1.5 | 10 | 145 | – | ≤12.1 | – | 3.5 | 20 | – | 27 | – |
3×1.6 | 0.7 | 1.5 | 11 | 185 | 140 | ≤7.41 | ≤12.1 | 3.5 | 26 | 20 | 35 | 27 |
3×4 | 0.7 | 1.5 | 12 | 250 | 175 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
3×6 | 0.7 | 1.5 | 13 | 320 | 210 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
3×10 | 0.7 | 1.5 | 15 | 450 | 260 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Four Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
4×4 | 0.7 | 1.5 | 13 | 253 | 155 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
4×6 | 0.7 | 1.5 | 14 | 337 | 184 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
4×10 | 0.7 | 1.5 | 16 | 501 | 258 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
We are China XLPE PVC Insulation 185 Sqmm 240 Sqmm LV Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: 185 Sqmm LV Power Cable, 240 Sqmm low voltage electrical cable, 240 Sqmm LV Power Cable, LV Power Cable