Nominal Section:3*25~3*400mm² CU/ Al Conductor LV Power Cable(Unamoured) XLPE Insulation (AL/CU/XLPE/LSZH/NYY/N2XY)
Nominal Section:3*25~3*400mm² CU/ Al Conductor LV Power Cable(Unamoured) XLPE Insulation (AL/CU/XLPE/LSZH/NYY/N2XY) image
Brand Name :
Zhenglan cable
Model Number :
CU/ Al Conductor LV Power Cable(Unamoured)
Certification :
3C,ISO 9001:2015,ISO 14001:2005
Place of Origin :
China
MOQ :
100 meters
Payment Terms :
L/C, T/T, Western Union
Delivery Time :
15-30 days
Packaging Details :
Wooden drum, wood and steel drum, as customer’s request
Material :
AL/CU
Insulation :
XLPE
Application :
Power station
Standard :
IEC 60502
Packing :
wooden drum, wood and steel drum
Cores :
3
Character :
Unamoured
Nominal Section:3*25~3*400mm² CU/ Al Conductor LV Power Cable(Unamoured) XLPE Insulation (AL/CU/XLPE/LSZH/NYY/N2XY)
Application
General application as power cable. In low voltage distribution power networks, industrial installations, in buildings and operation stations. In fixed installations, indoor and outdoor areas. It can be installed in dry or wet locations; where mechanical strength is required.but it couldn't bear great pulling force. Used for power station, industry, switchgear and urban power supply network.
Standards
Basic design to IEC 60502-1, IEC 60228
China: GB/T 12706.2-2008
Other standards such as BS7870,DIN and ICEA upon request
Cable Construction:
Conductor | The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228. |
Conductor Shape | Circular Stranded or Compacted Circular Stranded |
Appearance Shape | Circular |
Insulation | XLPE Insulation material and thickness shall be as per IEC 60502-1, rated for 90°C continuous operation. |
Colour Code |
3Cores: Red, Yellow, Blue |
Assembly/Inner Covering | The inner coverings may be extruded or lapped. For cables with circular cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. |
Armour | Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request. |
Outer Sheath | extruded Polyethylene type ST3/ST7,Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2. |
Characteristics:
Good electrical and mechanical properties. XLPE insulation allows greater power capacity under any operating condition, minimum dielectric losses, high insulation resistance. Its armour provides additional mechanical protection.
Electrical Properties:
Rated Voltage Uo/U (Um) | 600/1000V, BS5467 |
Max. DC resistance of the conductor at 20°C | 7.41Ohm/km |
Perm current rating in air 30°C | 32A |
Permissible current rating buried 20°C | 44A |
Installation Temperature | Minimum: 0°C,Maximum: 60°C |
Installation Type | Outdoor Direct burial |
Operating Temperature | Maximum: 90°C. |
Short-circuit Maximum Conductor Temperature: | 250°C. |
Min. Bending Radius | 12 x cable O.D for multi-core armoured cables |
Packing Details:
1. standard seaworthy drum (wooden drum,wooden steel drum, steel drum) are available;
2. drum size can be customized or meeting container the Max.load size;
3. drum overall diameter can be from 1 meter to 2.5 meters;
4. under customer requirement with certain length packed in rolls wrapped in plastic tape or Nylon plastic tape.
Construction Parameters:
IEC 60502-1
Nominal Cross Section of Conductor | Nominal Diameter of Conductor | Nominal Thickness of Insulation | Nominal Thickness of Copper Tape Screen | Nominal Thickness of Inner Sheath | Nominal Thickness of Steel Tape Armouring | Nominal Thickness of PE Sheath | Approx. Overall Diameter | Approx. Weight | |
Al Conductor | Cu Conductor | ||||||||
No. X mm2 | mm | mm | mm | mm | mm | mm | mm | kg/m | kg/m |
3 X 25 | 6.0 | 3.4 | 0.1 | 1.3 | 0.5 | 2.0 | 43.4 | 2.16 | 2.61 |
3 X 35 | 6.9 | 3.4 | 0.1 | 1.3 | 0.5 | 2.0 | 45.4 | 2.36 | 2.99 |
3 X50 | 8.2 | 3.4 | 0.1 | 1.4 | 0.5 | 2.2 | 48.8 | 2.69 | 3.54 |
3 X 70 | 9.7 | 3.4 | 0.1 | 1.5 | 0.5 | 2.3 | 52.4 | 3.10 | 4.33 |
3 X 95 | 11.3 | 3.4 | 0.1 | 1.5 | 0.5 | 2.4 | 56.1 | 3.56 | 5.26 |
3 X 120 | 12.8 | 3.4 | 0.1 | 1.5 | 0.5 | 2.5 | 59.5 | 4.04 | 6.19 |
3 X 150 | 14.2 | 3.4 | 0.1 | 1.5 | 0.5 | 2.6 | 62.7 | 4.49 | 7.19 |
3 X 185 | 15.9 | 3.4 | 0.1 | 1.6 | 0.5 | 2.6 | 66.6 | 5.12 | 8.49 |
3 X 240 | 18.3 | 3.4 | 0.1 | 1.7 | 0.5 | 2.8 | 72.4 | 5.99 | 10.42 |
3 X 300 | 20.4 | 3.4 | 0.1 | 1.8 | 0.5 | 3.0 | 77.5 | 6.86 | 12.42 |
3 X 400 | 23.2 | 3.4 | 0.1 | 1.9 | 0.8 | 3.2 | 85.4 | 8.97 | 16.05 |
We are China Nominal Section:3*25~3*400mm² CU/ Al Conductor LV Power Cable(Unamoured) XLPE Insulation (AL/CU/XLPE/LSZH/NYY/N2XY) manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: low voltage electrical cable, low voltage flexible cable, Low Voltage Power Cable