0.6/1 KV Fire Resistant Electrical Wire , Fire Rated Cable For Fire Alarm System

 China 0.6/1 KV Fire Resistant Electrical Wire , Fire Rated Cable For Fire Alarm System supplier

0.6/1 KV Fire Resistant Electrical Wire , Fire Rated Cable For Fire Alarm System image

Get a Quote Email to us

Brand Name :
Shenzhen Chengtiantai

Model Number :
YTTW

Certification :
CCC

Place of Origin :
Guangdong,China(Mainland)

MOQ :
100 units

Price :
on request

Payment Terms :
L/C, T/T

Supply Ability :
50,000 m/day

Delivery Time :
7 / 15 working days

Packaging Details :
steel wooden drum

Rate Voltage :
0.6/1 KV

Conductor :
Bare copper class 2

Light Duty :
500 V

Insulation :
mica tape

Heavy Duty :
750 V

Sheath :
Copper metallic sheath

Fire resistance cable YTTW

YTTW cable is designed for aboveground applications.

Engineered to replace conduit and wire applications, this all-in-one cable assembly offers fewer installation steps.

The copper metallic sheath protects the conductors from damage before,during and after installation and provides overall flexibility not available with a conduit.

— Flame Retardant
— High Operating Temperatures

LSOH Halogen-free
Great Mechanical Strength
Competitive Installed Cost
Public Places

Our YTTW cables provide outstanding electrical and fire-proof properties, and are halogen free.

The design, construction and testing are compliant with international standard IEC60502 and testing standard EN 50200 (PH-90),with standing temperatures of 840 °C for 90 minutes, which means they are capable of remaining in working order despite the most extreme fire conditions. Hence they are known as FIRE RESISTANT cables.

This type of cable is made up of single and multi-cores 600/1000V cables Service Temperature 90°C Emergency Overload Temperature 105°C Short-Circuit Temperature 250°C

Installation of these cables is essential in safety circuits (detection and alarm circuits,evacuation and fire-fighting systems).

STANDARDS:
National International
Construction GB/T 12706 IEC 60502
Non fire-propagating GB/T 18380.3 IEC 60332-3
Low opacity of smoke emitted GB/T 17651.2 IEC 61034-2
Fire-resistant GB/T 12666.6 IEC 60331
Low acidity and corrosiveness of gases GB/T 17650.2 IEC 60754-2
Halogen free GB/T 17650.2 IEC 60754-1
Non flame-propagating GB/T 18380.1 IEC 60332-1-2

Rated working voltage:

–​ Light Duty: 500 V

–​ Testing Voltage (50 Hz): 2500 V – 15 min

–​ Heavy Duty: 750 V

–​ Testing Voltage (50 Hz): 2000 V – 15 min

Cable structure
Conductor Stranded copper conductor class 2
Insulation mica tape1, flame retardant
Filler Glass yarns
core wraping Core wrapping with glass-fibre tape as flame-protection
Sheath Corrugated Copper
Outer covering (Optional) Anticorrosion Outer Sheath PVC
USAGE CHARACTERISTICS
Service Temperature 90°C
Emergency Overload Temperature 105°C
Short-Circuit Temperature 250°C
Laying Temperature should not be lower than 0°C
Minimum bending radius when laying Single core: r = 6 x cable outer diameter
Sheath colour The standard color is orange, other colors are available.

SINGLE CONDUCTOR

Nominal

cross

Section

Nominal insulation thickness

Thickness of

metallic

sheath

Outer

Diameter

approx.

current

carrying

capacity

Voltage

drop
cos μ= 0,8

mm2 mm mm mm A V/A.km
1×1.0 0.80 0.40 3.53 23.10
1×1.5 0.80 0.40 3.78 32 15.40
1×2.5 0.80 0.40 4.18 42 9.48
1×4.0 0.80 0.50 4.85 56 5.90
1×6.0 0.80 0.50 5.36 70 3.90
1×10 1.00 0.50 7.02 97 2.33
1×16 1.00 0.60 8.24 125 1.47
1×25 1.00 0.60 9.56 165 0.92
1×35 1.00 0.60 10.70 200 0.67
1×50 1.20 0.70 12.60 245 0.49
1×70 1.20 0.70 14.40 305 0.34
1×95 1.20 0.80 16.50 375 0.25
1×120 1.20 0.80 18.14 435 0.20
1×150 1.40 0.80 20.15 500 0.16
1×185 1.40 0.90 22.10 580 0.13
1×240 1.40 0.90 24.85 685 0.10
1×300 1.60 1.00 27.70 795 0.08
1×400 1.60 1.00 30.40 930 0.06

2 CONDUCTOR

Nominal

cross

Section

Nominal Insulation thickness

Thickness of

metallic

sheath

Outer

Diameter

approx.

Ampacity

Voltage

drop
cos μ= 0,8

mm2 mm mm mm A V/A.km
2×2.5 0.80 0.50 6.96 33 18.96
2×4.0 0.80 0.60 8.10 44 11.8
2×6.0 0.80 0.60 9.12 57 7.8
2×10 1.00 0.70 12.44 78 4.66
2×16 1.00 0.70 14.48 104 2.86
2×25 1.00 0.80 17.32 135 2.52
2×35 1.10 0.80 19.90 168 2.24
2×50 1.20 0.90 23.00 204 1.64
2×70 1.20 1.00 26.80 263 1.42
2×95 1.20 1.00 30.60 320 1.08
2×120 1.20 1.00 33.88 373 0.98

THREE CONDUCTOR

Nominal
cross
Section

Nominal insulation thickness Thickness of

metallic

sheath

Outer

Diameter

approx.

Ampacity

Voltage

drop
cos μ= 0,8

mm2 mm mm mm A V/A.km
3×2.5 0.8 0.60 7.56 29 16.4
3×4.0 0.8 0.60 8.57 38 10.2
3×6.0 0.8 0.60 9.67 46 6.74
3×10 1.0 0.70 13.22 65 4.03
3×16 1.0 0.70 15.42 85 2.54
3×25 1.0 0.80 18.46 118 1.59
3×35 1.1 0.80 21.43 150 1.16
3×50 1.2 0.90 24.55 192 0.85
3×70 1.2 1.00 28.63 228 0.59
3×95 1.2 1.00 32.72 273 0.43
3×120 1.2 1.00 36.26 314 0.35

FOUR CONDUCTOR

Nominal
cross
Section
Nominal insulation thickness Thickness of

metallic

sheath

Outer

Diameter

approx.

Ampacity Voltage

drop
cos μ= 0,8

mm2 Mm mm mm A V/A.km
4×6.0 0.8 0.60 10.59 46 6.74
4×10 1.0 0.70 14.52 65 4.03
4×16 1.0 0.80 17.18 85 2.54
4×25 1.0 0.90 20.57 118 1.59
4×35 1.1 1.00 23.86 150 1.16
4×50 1.2 1.00 27.34 192 0.85
4×70 1.2 1.00 31.69 228 0.59
4×95 1.2 1.00 36.27 273 0.43

3+1 CORE
Nominal
cross
Section
Nominal insulation thickness Thickness of

metallic

sheath

Outer

Diameter

approx.

Ampacity Voltage

drop
cos μ= 0,8

mm2 mm mm mm A V/A.km
3×16+1×10 1.0 0.80 16.56 85 2.54
3×25+1×16 1.0 0.90 19.77 118 1.59
3×35+1×16 1.1 1.00 22.18 150 1.16
3×50+1×25 1.2 1.00 25.87 192 0.85
3×70+1×35 1.2 1.00 29.81 228 0.59
3×90+1×50 1.2 1.00 34.04 273 0.43

Notes:

Ampacities based on 90°C conductor temperature and 40°C ambient temperature according to IEC 287 standard

The voltage drop based on conductor temperature 90°C is on the high side calculated only for reference

When the cable adopt compressed cores, diameter of cable should be 95% of normal diameter, diameter of metallic sheath should be adjusted correspondingly. When enhancing the insulation, outer diameter of cable is increased for about 5%.

1 Glass cloth reinforced Muscovite mica tape

2 Current ratings in Ampere (A) up to 30° C ambient temperature

We are China 0.6/1 KV Fire Resistant Electrical Wire , Fire Rated Cable For Fire Alarm System manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Tags: , ,