Copper 0.6/1 KV XLPE Insulated Power Cable Low Voltage Power Cables
Copper 0.6/1 KV XLPE Insulated Power Cable Low Voltage Power Cables image
Brand Name :
Chengtiantai cable
Model Number :
YJV
Certification :
CE, CB
Place of Origin :
Shenzhen City, Mainland China
MOQ :
Negotiable
Price :
Negotiable
Payment Terms :
L/C, T/T
Delivery Time :
15 working days after payments
Packaging Details :
Steel wooden Drum
Nominal Voltage :
0.6/1 kV
Insulation :
XLPE
No. of Conductor :
from 1 to 5 core
Sheath :
PVC Compound
Conductor Material :
Bare Copper Class 2
Manufacturer :
Shenzhen Chengtiantai
COPPER CABLES- NON ARMOURED XLPE INSULATION POWER CABLE
0.6/1 KV CU/XLPE/PVC – N2XY
Application of XLPE Insulated copper cable
IEC 60502-1 XLPE Insulated copper cable are used for electricity supply in low voltage installation system, IEC 60502-1 XLPE Insulated copper cable are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
Applicable Standards of XLPE Insulated copper cable
– IEC 60502-1 Design and Test Guidelines
– IEC 60228 Conductor
– IEC 60332-1 Flame Retardant
– IEC 60332-3-24 Flame Retardant Cat. C
1. Conductor: 2. Insulation: – Cross-linked polyethylene (XLPE) 3. Filler – non-hygroscoppic polypropylene(PP) filler 4. Inner Sheath (Bedding ) for armoured cables – Polyvinyl chloride (PVC) Colour :black 5. Armour: – Galvanized steel tape for multi core cable 6.Outer sheath: – Polyvinyl chloride (PVC) – Colour: black. Other colour on request. Special Feature On Request – Flame Retardant Cat.C |
|
Electrical Characteristics
Rated Voltage Uo/U |
0.6/1 kV |
Maximum operating voltage |
1.2 kV |
Frequence |
50 Hz |
Test voltage : |
3500 V |
Usage Characteristics
Permissible operating temperature at conductor |
+90°C |
short circuit temperature ( duration max. 5 s) |
250 °C |
Minimum installation temperature |
should not be lower than 0°C |
Max. conductor permissible tensile stress |
50 N/mm² |
Minimum bending radius |
15 x cable Ø |
Physical and Electrical Characteristics:
LV Power Cable copper core XLPE Insualed cable Single Core
No.cores x |
Insulation |
Sheath |
Outer Ø |
weight |
Current ratings in air 30℃ |
Current ratings buried 20℃ |
maximum DC resistance at 20℃ |
mm² |
mm |
mm |
mm |
kg / km |
A |
A |
Ω/km |
1×1.5 |
0.7 |
1.4 |
5.8 |
45 |
32 |
43 |
12.1 |
1×2.5 |
0.7 |
1.4 |
6.2 |
57 |
42 |
57 |
7.41 |
1×4.0 |
0.7 |
1.4 |
6.7 |
75 |
56 |
74 |
4.61 |
1×6.0 |
0.7 |
1.4 |
7.2 |
97 |
70 |
93 |
3.08 |
1×10 |
0.7 |
1.4 |
8.2 |
142 |
97 |
127 |
1.83 |
1×16 |
0.7 |
1.4 |
9.2 |
205 |
125 |
167 |
1.15 |
1×25 |
0.9 |
1.4 |
10.8 |
304 |
165 |
216 |
0.73 |
1×35 |
0.9 |
1.4 |
11.8 |
403 |
200 |
261 |
0.52 |
1×50 |
1.0 |
1.4 |
13.3 |
555 |
245 |
311 |
0.39 |
1×70 |
1.1 |
1.4 |
15.3 |
756 |
305 |
388 |
0.27 |
1×95 |
1.1 |
1.5 |
17.1 |
1005 |
375 |
461 |
0.19 |
1×120 |
1.2 |
1.5 |
18.7 |
1250 |
435 |
527 |
0.15 |
1×150 |
1.4 |
1.6 |
20.9 |
1561 |
500 |
592 |
0.12 |
1×185 |
1.6 |
1.6 |
22.9 |
1910 |
580 |
671 |
0.10 |
1×240 |
1.7 |
1.7 |
25.5 |
2453 |
685 |
781 |
0.08 |
1×300 |
1.8 |
1.8 |
28.2 |
3044 |
795 |
886 |
0.06 |
1×400 |
2.0 |
1.9 |
32.0 |
4024 |
930 |
1019 |
0.05 |
1×500 |
2.2 |
2.0 |
35.4 |
5006 |
1080 |
1170 |
0.04 |
LV Power Cable copper core XLPE Insualed cable 2 Cores
No.cores x |
Insulation |
Sheath |
Outer Ø |
weight |
Current ratings in air 30℃ |
Current ratings buried 20℃ |
maximum DC resistance at 20℃ |
mm² |
mm |
mm |
mm |
kg / km |
A |
A |
Ω/km |
2×2.5 |
0.7 |
1.8 |
10.6 |
140 |
37 |
54 |
7.41 |
2×4.0 |
0.7 |
1.8 |
11.6 |
192 |
47 |
70 |
4.61 |
2×6.0 |
0.7 |
1.8 |
12.6 |
245 |
60 |
86 |
3.08 |
2×10 |
0.7 |
1.8 |
15.2 |
362 |
84 |
115 |
1.83 |
2×16 |
0.7 |
1.8 |
16.6 |
514 |
113 |
149 |
1.15 |
2×25 |
0.9 |
1.8 |
19.8 |
734 |
150 |
191 |
0.73 |
2×35 |
0.9 |
1.8 |
17.2 |
968 |
185 |
231 |
0.52 |
2×50 |
1.0 |
1.8 |
19.4 |
1190 |
226 |
275 |
0.39 |
2×70 |
1.1 |
1.9 |
22.0 |
1591 |
287 |
337 |
0.27 |
2×95 |
1.1 |
2.0 |
24.6 |
2117 |
354 |
405 |
0.19 |
2×120 |
1.2 |
2.1 |
27.4 |
2617 |
431 |
463 |
0.15 |
2×150 |
1.4 |
2.2 |
30.2 |
3239 |
494 |
522 |
0.12 |
2×185 |
1.6 |
2.3 |
34.0 |
5126 |
592 |
591 |
0.10 |
LV Power Cable copper core XLPE Insualed cable 3 Cores
No.cores x |
Insulation |
Sheath |
Outer Ø |
weight |
Current ratings in air 30℃ |
Current ratings buried 20℃ |
maximum DC resistance at 20℃ |
mm² |
mm |
mm |
mm |
kg / km |
A |
A |
Ω/km |
3×1.5 |
0.7 |
1.8 |
10.1 |
132 |
21 |
28 |
12.1 |
3×2.5 |
0.7 |
1.8 |
11.0 |
171 |
28 |
37 |
7.41 |
3×4.0 |
0.7 |
1.8 |
12.0 |
225 |
37 |
48 |
4.61 |
3×6.0 |
0.7 |
1.8 |
13.1 |
296 |
47 |
61 |
3.08 |
3×10 |
0.7 |
1.8 |
15.3 |
440 |
64 |
82 |
1.83 |
3×16 |
0.7 |
1.8 |
17.5 |
638 |
85 |
107 |
1.15 |
3×25 |
0.9 |
1.8 |
21.0 |
954 |
115 |
138 |
0.73 |
3×35 |
0.9 |
1.8 |
23.1 |
1266 |
140 |
165 |
0.52 |
3×50 |
1.0 |
1.8 |
23.4 |
1614 |
168 |
198 |
0.39 |
3×70 |
1.1 |
1.9 |
27.4 |
2264 |
213 |
242 |
0.27 |
3×95 |
1.1 |
2.0 |
30.6 |
2975 |
263 |
290 |
0.19 |
3×120 |
1.2 |
2.1 |
34.0 |
3776 |
307 |
330 |
0.15 |
3×150 |
1.4 |
2.3 |
38.6 |
4682 |
357 |
371 |
0.12 |
3×185 |
1.6 |
2.4 |
43.3 |
5802 |
415 |
418 |
0.10 |
3×240 |
1.7 |
2.6 |
48.1 |
7437 |
498 |
485 |
0.08 |
3×300 |
1.8 |
2.8 |
52.2 |
9313 |
575 |
548 |
0.06 |
LV Power Cable copper core XLPE Insualed cable 4 Cores
No.cores x |
Insulation |
Sheath |
Outer Ø |
weight |
Current ratings in air 30℃ |
Current ratings buried 20℃ |
maximum DC resistance at 20℃ |
mm² |
mm |
mm |
mm |
kg / km |
A |
A |
Ω/km |
4×4 |
0.7 |
1.8 |
13.0 |
283 |
38 |
50 |
4.61 |
4×6 |
0.7 |
1.8 |
14.2 |
376 |
49 |
62 |
3.08 |
4×10 |
0.7 |
1.8 |
16.7 |
567 |
67 |
84 |
1.83 |
4×16 |
0.7 |
1.8 |
19.1 |
829 |
88 |
109 |
1.15 |
4×25 |
0.9 |
1.8 |
23.2 |
1249 |
119 |
142 |
0.73 |
4×35 |
0.9 |
1.8 |
25.2 |
1689 |
146 |
170 |
0.52 |
4×50 |
1.0 |
1.9 |
25.5 |
2146 |
173 |
201 |
0.39 |
4×70 |
1.1 |
2.0 |
28.9 |
2944 |
218 |
245 |
0.27 |
4×95 |
1.1 |
2.1 |
32.5 |
3903 |
271 |
294 |
0.19 |
4×120 |
1.2 |
2.3 |
35.9 |
4967 |
315 |
333 |
0.15 |
4×150 |
1.4 |
2.4 |
40.2 |
6133 |
366 |
374 |
0.12 |
4×185 |
1.6 |
2.6 |
44.4 |
7600 |
422 |
421 |
0.10 |
4×240 |
1.7 |
2.8 |
49.4 |
9743 |
508 |
489 |
0.08 |
4×300 |
1.8 |
3.0 |
56.0 |
12271 |
592 |
555 |
0.06 |
LV Power Cable copper core XLPE Insualed cable 3 Core+ Earth
No.cores x cross-sec. |
Insulation thickness |
Nominal Sheath thickness |
Outer Ø approx. |
weight approx. |
Current ratings in air 30℃ |
Current ratings buried 20℃ |
|
Phase |
Neutral |
||||||
mm² |
mm |
mm |
mm |
mm |
kg / km |
A |
A |
3×4+1×2.5 |
0.7 |
0.7 |
1.8 |
12.7 |
277 |
37 |
47 |
3×6+1×4.0 |
0.7 |
0.7 |
1.8 |
13.9 |
363 |
47 |
60 |
3×10+1×6.0 |
0.7 |
0.7 |
1.8 |
16.1 |
527 |
64 |
81 |
3×16+1×10 |
0.7 |
0.7 |
1.8 |
18.6 |
766 |
85 |
106 |
3×25+1×16 |
0.9 |
0.7 |
1.8 |
22.2 |
1140 |
113 |
137 |
3×35+1×16 |
0.9 |
0.7 |
1.8 |
24.6 |
1475 |
139 |
164 |
3×50+1×25 |
1.0 |
0.9 |
1.8 |
27.7 |
1951 |
173 |
198 |
3×70+1×35 |
1.1 |
0.9 |
1.9 |
31.9 |
2662 |
222 |
246 |
3×95+1×50 |
1.1 |
1.0 |
2.1 |
36.2 |
3578 |
271 |
293 |
3×120+1×70 |
1.2 |
1.1 |
2.2 |
39.9 |
4567 |
318 |
334 |
3×150+1×70 |
1.4 |
1.1 |
2.3 |
45.0 |
5514 |
370 |
375 |
3×185+1×95 |
1.6 |
1.1 |
2.5 |
49.4 |
6850 |
427 |
422 |
3×240+1×120 |
1.7 |
1.2 |
2.7 |
54.9 |
8741 |
507 |
492 |
3×300+1×150 |
1.8 |
1.4 |
2.9 |
62.9 |
11052 |
599 |
560 |
LV Power Cable copper core XLPE Insualed cable 5 Cores
No.cores x |
Insulation |
Sheath |
Outer Ø |
weight |
Current ratings in air 30℃ |
Current ratings buried 20℃ |
maximum DC resistance at 20℃ |
mm² |
mm |
mm |
mm |
kg / km |
A |
A |
Ω/km |
5×4 |
0.7 |
1.8 |
14.7 |
320 |
38 |
48 |
4.61 |
5×6 |
0.7 |
1.8 |
15.8 |
427 |
48 |
60 |
3.08 |
5×10 |
0.7 |
1.8 |
18.6 |
636 |
66 |
81 |
1.83 |
5×16 |
0.7 |
1.8 |
21.3 |
941 |
88 |
107 |
1.15 |
5×25 |
0.9 |
1.8 |
25.7 |
1441 |
118 |
137 |
0.73 |
5×35 |
0.9 |
1.8 |
28.4 |
1853 |
144 |
165 |
0.52 |
5×50 |
1.0 |
2.0 |
32.9 |
2616 |
177 |
196 |
0.39 |
5×70 |
1.1 |
2.1 |
38.2 |
3578 |
227 |
244 |
0.27 |
5×95 |
1.1 |
2.3 |
43.4 |
4843 |
277 |
288 |
0.19 |
5×120 |
1.2 |
2.4 |
47.9 |
6110 |
325 |
329 |
0.15 |
5×150 |
1.4 |
2.6 |
53.8 |
7421 |
375 |
369 |
0.12 |
5×185 |
1.6 |
2.8 |
59.6 |
9191 |
433 |
418 |
0.10 |
5×240 |
1.7 |
3.0 |
66.5 |
11763 |
518 |
488 |
0.08 |
5×300 |
1.8 |
3.2 |
73.4 |
14595 |
625 |
555 |
0.06 |
LV Power Cable copper core XLPE Insualed cable 4 Core+Earth
No.cores x cross-sec. |
Insulation thickness |
Nominal Sheath thickness |
Outer Ø approx. |
weight approx. |
Current ratings in air 30℃ |
Current ratings buried 20℃ |
|
Phase |
Neutral |
||||||
mm² |
mm |
mm |
mm |
mm |
kg / km |
A |
A |
4×4+1×2.5 |
0.7 |
0.7 |
1.8 |
14.2 |
320 |
38 |
48 |
4×6+1×4.0 |
0.7 |
0.7 |
1.8 |
15.6 |
427 |
48 |
60 |
4×10+1×6.0 |
0.7 |
0.7 |
1.8 |
18.1 |
636 |
66 |
81 |
4×16+1×10 |
0.7 |
0.7 |
1.8 |
20.8 |
941 |
88 |
107 |
4×25+1×16 |
0.9 |
0.7 |
1.8 |
24.9 |
1441 |
118 |
137 |
4×35+1×16 |
0.9 |
0.7 |
1.8 |
27.1 |
1853 |
144 |
165 |
4×50+1×25 |
1.0 |
0.9 |
1.9 |
31.6 |
2616 |
177 |
196 |
4×70+1×35 |
1.1 |
0.9 |
2.1 |
36.5 |
3578 |
227 |
244 |
4×95+1×50 |
1.1 |
1.0 |
2.2 |
41.6 |
4843 |
277 |
288 |
4×120+1×70 |
1.2 |
1.1 |
2.4 |
46.3 |
6110 |
325 |
329 |
4×150+1×70 |
1.4 |
1.1 |
2.5 |
51.2 |
7421 |
375 |
369 |
4×185+1×95 |
1.6 |
1.1 |
2.7 |
56.8 |
9191 |
433 |
418 |
4×240+1×120 |
1.7 |
1.2 |
2.9 |
63.2 |
11763 |
518 |
488 |
4×300+1×150 |
1.8 |
1.4 |
3.1 |
70.0 |
14595 |
625 |
555 |
*Dimensions and specifications may be changed without prior notice.
similary products
Hook-up wire |
0.6/1 kV PVC Cable |
XLPE MV power cable |
|
|
|
Hook-up wire » |
LV PVC Cable » |
XLPE Insulated MV power cable » |
Packaging & Delivery
Packaging details : |
Delivery : |
|
|
|
|
Steel Wooden Drums |
Cable Drum In container |
shipped in 15 days after payment |
Cable Drum Data
CABLE DRUMS |
D1=Flange Diameter(mm) |
W=Useful Width (mm) |
D2=Barrel Diameter(mm) |
|
1000 |
700 |
500 |
1100 |
700 |
550 |
|
1200 |
700 |
600 |
|
1400 |
750 |
710 |
|
1600 |
900 |
900 |
|
1800 |
1120 |
1000 |
|
2400 |
1150 |
1300 |
Delivery Port:
|
|
|
Port of Shenzhen |
Port of Hongkong |
Port of Guangzhou |
Manufacturing Process Of Low Voltage Power Cable ( Unarmored )
|
|
|
1. copper rod |
2. wire drawing |
3. wire stranding |
|
|
|
4.Inner sheath |
5. Assembling |
6.outer covering Process |
|
|
|
7. Sheath Marking |
8. Packing |
9. cable delivering |
Our production in numbers
|
|
Cable production started 1983 Sales in 2016 about 500 million USD 100,000 m2 Production area |
200 Sets Of Testing Equipment 100 Testing Items |
Some great shots of our manufactering plant
|
|
|
Mannufacturing plant |
R&D Building |
Bird's eye view of the plant |
|
|
|
MV Power Cable Workshop |
Cable Reels Waiting to be shipped out |
Shipping |
Shenzhen chengtiantai cable operates certified management systems compliant with:
Certificat |
Information |
|
|
ISO 9001:2008 quality management systems |
Certificat ISO 9001:2008 |
|
ISO 14001:2004 environmental management systems |
Certificat ISO 14001:2004 – Shenzhen chengtiantai cable industry development Co.Ltd. ; Certified through Guangdong quality Testing CTC Certification Co.Ltd.; Valid until 9th January 2022 |
|
OHSAS 18001:2007 assessment specification for occupational health & safety management systemsenvironmental management systems |
Certificat OHSAS 18001:2007 – Shenzhen chengtiantai cable industry development Co.Ltd. ; Certified through Guangdong quality Testing CTC Certification Co.Ltd.; Valid until 9th January 2022 |
Customer services:
Haven't found what you were looking for. contact our Sales manager [email protected]
Please provide your contact information so that we can contact you soon to help with your request.
Tel:+86 755 6114 5028 | Fax:+86 755 61137976 | E-mail: [email protected]
We are China Copper 0.6/1 KV XLPE Insulated Power Cable Low Voltage Power Cables manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: xlpe copper cable, XLPE Insulated Power Cable, xlpe pvc cable