0.6/1KV CU/XLPE/PVC N2XY Copper Conductor XLPE Insulated Electric Power Cable
0.6/1KV CU/XLPE/PVC N2XY Copper Conductor XLPE Insulated Electric Power Cable image
0.6/1 KV CU/XLPE/PVC N2XY Copper Conductor XLPE Insulated Electric Power Cable
Cu(AL)/XLPE/SWA/PVC LV armoured Cable Application
Cu(AL)/XLPE/SWA/PVC LV armoured Cable is a aluminum or copper cable with XLPE insulation SWA Armour. They are used for power networks, direct burial, outdoors, indoors and in cable ducts for electricity supply in low voltage installation system
Cu(AL)/XLPE/SWA/PVC LV armoured Cable construction
Conductors: Plain annealed stranded copper
Insulation: XLPE (Cross linked polyethylene)
Bedding: PVC (Polyvinyl-Chloride)
Armour/Protection: SWA (Galvanised single wire armour) (optional feature as per actual needs)
Sheath/Jacket: PVC (Polyvinyl-Chloride)
Colour: Black
Voltage: 600/1000v
Operating temperature: Maximum 90°C. Minimum bending 0°C
Technical data
Operating voltage:1000 V
Test voltage: 3500V, according to IEC 60502
Operation temperature:–25°C to + 90°C
Permissible short therm: + 250°C
Bending radius:
1.5mm2 to 16mm2 – Fixed: 6 x overall diameter
25mm2 and above – Fixed: 8 x overall diameter
0.6/1KV CU/XLPE/PVC N2XY Copper Conductor XLPE Insulated Electric Power Cable Core identification:
Two Core – Brown, Blue
Three Core – Brown, Black & Grey (Optional: Brown, Blue & Green/Yellow)
Four Core – Brown, Black, Grey & Blue (Optional: Brown, Black, Grey & Green/Yellow)
Five Core – Numbered Cores (Optional: Brown, Black, Grey, Blue + Green/Yellow)
Six Core and Above – Numbered Cores (optional numbered + Green and Yellow)
0.6/1KV CU/XLPE/PVC N2XY Copper Conductor XLPE Insulated Electric Power Cable Referece Standard:
BS5467: Electric cables. Thermosetting insulated, armoured cables for voltages of 600/1000V and 1900/3300V
IEC60502: Power cables with extruded insulation and their accessories for rated voltages from 1kV to 30kV
Flame Propagation Test to BS EN 60332-1-2 for single cable
0.6/1KV CU/XLPE/PVC N2XY Copper Conductor XLPE Insulated Electric Power Cable parameters
Nominal Area |
Approx Conductor Diameter |
Nominal Insulation thickness |
Nominal bedding thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Approx. Overall Diameter |
Approx. Weight |
mm² | mm | mm | mm | mm | mm | mm | Kg/km |
4×1.5 | 1.6 | 0.7 | 1 | 0.9 | 1.8 | 15 | 415 |
4×2.5 | 2 | 0.7 | 1 | 0.9 | 1.8 | 17.5 | 490 |
4×4 | 2.6 | 0.7 | 1 | 0.9 | 1.8 | 19 | 600 |
4×6 | 3.1 | 0.7 | 1 | 0.9 | 1.8 | 20 | 730 |
4×10 | 4 | 0.7 | 1 | 1.25 | 1.8 | 23 | 970 |
4×16 | 5 | 0.7 | 1 | 1.6 | 1.8 | 26 | 1520 |
4×25 | 6.3 | 0.9 | 1 | 1.6 | 1.8 | 29 | 2010 |
4×35 | 7.4 | 0.9 | 1 | 1.6 | 1.9 | 31 | 2560 |
4×50 | 8.8 | 1 | 1 | 1.6 | 2.1 | 36 | 3350 |
4×70 | 10.6 | 1.1 | 1.2 | 2 | 2.2 | 40 | 4680 |
4×95 | 12.4 | 1.1 | 1.2 | 2 | 2.4 | 44 | 5710 |
4×120 | 14 | 1.2 | 1.4 | 2.5 | 2.5 | 50 | 7500 |
4×150 | 15.5 | 1.4 | 1.4 | 2.5 | 2.6 | 55 | 9010 |
4×185 | 17.4 | 1.6 | 1.4 | 2.5 | 2.8 | 61 | 10820 |
4×240 | 20.3 | 1.7 | 1.6 | 2.5 | 3.1 | 69 | 13630 |
4×300 | 22.7 | 1.8 | 1.6 | 2.5 | 3.2 | 75 | 16820 |
4×400 | 25.4 | 2 | 1.8 | 3.15 | 3.4 | 83 | 22230 |