Aerial Bunched Overhead Insulated Cable XLPE+AAC XLPE 2X2AWG ANSI ICEA S-76-474
Aerial Bunched Overhead Insulated Cable XLPE+AAC XLPE 2X2AWG ANSI ICEA S-76-474 image
Duplex Service Drop AAC/XLPE+AAC/XLPE 2X2AWG Overhead Insulated Cable Aerial Bunched Cable ANSI/ICEA S-76-474
Application:
Duplex Service cable overhead insulated cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. And this cable support Maximum operating temperature not to exceed 90°C in wet and dry locations.
Structure
Phase cable Conductor material: AAC;
Phase cable Insulation material: XLPE;
Neutral conductor material: AAC/ACSR/AAAC
Neutral conductor insulation: XLPE
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire.
Duplex service drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
Parameters:
DUPLEX | |||||||||||
Nombre clave Code Name |
Calibre Size AWG |
Nº hilos Strands |
Espesor de aislamiento Insulation Thickness mm |
Calibre Size AWG |
Nº hilos Strands |
Carga a la rotura Breaking Load Kgf |
Diámetro Exterior External Diameter mm |
Masa total Total Weight kg/km |
Capacidad de corriente Ampacity A* |
Corriente de corto circuito** Short Circuit Current kA |
Resistencia DC del conductor a 20°C Nominal DC Resistance at 20°C Ω/km |
Neutro Mensajero tipo ACSR | |||||||||||
Terrier | 4 | 7 | 1.14 | 4 | 7 | 845 | 16.7 | 245.28 | 104 | 1.5 | 1.3592 |
Chow | 2 | 7 | 1.14 | 2 | 7 | 1290 | 19.68 | 293.44 | 140 | 2.4 | 0.8546 |
Bloodhound | 1/0 | 7 | 1.52 | 1/0 | 7 | 1985 | 24.48 | 457.52 | 190 | 3.9 | 0.5373 |
Bull | 1/0 | 19 | 1.52 | 1/0 | 7 | 1985 | 24.68 | 459 | 190 | 3.9 | 0.5373 |
Neutro mensajero en aleación AAAC | |||||||||||
Schnauzer | 2 | 7 | 1.14 | 77.47 | 7 | 1272 | 19.68 | 260.288 | 140 | 2.4 | 0.8546 |
Afghan | 1/0 | 7 | 1.52 | 123.3 | 7 | 1940 | 24.48 | 410.816 | 190 | 3.9 | 0.5373 |
Heeler | 1/0 | 19 | 1.52 | 123.3 | 7 | 1940 | 24.68 | 410.368 | 190 | 3.9 | 0.5373 |
Products images:
Why Choose Zhenglan Cable:
- OEM/ODM services provided
- Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted
- Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007
- Advanced test equipment and procedures, 100% inspection before factory
- Enough stocks and the higest efficient shipping time guarranteed
- Professional pre-sales and after-sales services provided
- Strict quality control system, excellent quality with reasonable price.
FAQ
A: Is your company a factory or a trade company?
Factory, more than 20 years in China
B: How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days. The samples will be sent to you via express and arrive in 3~7 days. You can use your own express account or prepay us if you do not have an account.
C: What are your payment terms?
We normally accept T/T 30% deposit, 70% balance before delivery as the main payment terms, and other payment can also be negotiated. Trade assurance on Alibaba is also available.
D: What’s the delivery time?
Sample order needs 3~5 days. Formal order depends on the quantity. Usually it needs 7-30 days after get your payment.
E: What is your MOQ?
Generally it is 5000m.
We are China Aerial Bunched Overhead Insulated Cable XLPE+AAC XLPE 2X2AWG ANSI ICEA S-76-474 manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: Aerial Bunched Overhead Insulated Cable, ICEA S-76-474 Overhead Insulated Cable, Overhead Insulated Cable, XLPE 2X2AWG Overhead Insulated Cable