477MCM 37/2.88mm AAC All Aluminum Alloy Conductor ASTM B231/231M IEC61089
477MCM 37/2.88mm AAC All Aluminum Alloy Conductor ASTM B231/231M IEC61089 image
Brand Name :
Zhenglan Cable
Model Number :
AAC conductor 477MCM 37/2.88mm All aluminum alloy conductor ASTM B231/231M IEC61089
Certification :
3C,ISO 9001:2015,ISO 14001:2005
Place of Origin :
Henan, China
MOQ :
1000 meters
Price :
Negotiable
Payment Terms :
L/C, T/T,
Supply Ability :
20,0 KM/MOUTH
Delivery Time :
10-15 days
Packaging Details :
Fully wooden drum, steel wooden drum, fully steel drum or customized
Material :
aluminium
Size :
241.7sqmm
Quality :
100% test
Standard :
ASTM-B231/231M
Brand :
Zhenglan Cable
Stranding :
37/2.88mm
Port :
Shanghai or Qingdao
AAC conductor 477MCM 37/2.88mm All aluminum alloy conductor ASTM B231/231M IEC61089
AAC is mainly used as bare overhead transmission cable and as primary and secondary distribution cable. It is also suitable for laying across basins, rivers and valleys where special geographical teatures exist.
Place of Origin: Henan,China (Mainland)
Brand Name: ZHENGLAN
Insulation Material: none
Application: Overhead
Conductor Material: Aluminum, aluminum alloy
Jacket: none
Product name: Aluminum Conductor
Quality: 100% test
Size: AWG,mm2 or customized
Rated Voltage: 35kv/110kv/220kv/500kv
Packaging Details: fully wooden drum, steel wooden drum, fully steel drum or customized
STANDARD
Basic design to BS 215-1 / BS EN 50182 / IEC 61089 / ASTM B 231/B 231M / DIN 48201-5 standards
AAC conductor 477MCM 37/2.88mm All aluminum alloy conductor ASTM B231/231M IEC61089 Application:Concentric lay stranded Aluminium Conductor (AAC) is made up of one or more strands of hard drawn 1350 aluminum alloy. These conductors are used in low, medium and high voltage overhead lines. AAC has seen extensive use in urban areas where spans are usually short but high conductivity us required. The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas. Because of its relatively poor strength to weight ratio, AAC had limited use in transmission lines and rural distribution because of long spans utilized. All aluminium conductors are made up of one or more strands of aluminium wire dep.
AAC conductor 477MCM 37/2.88mm All aluminum alloy conductor ASTM B231/231M IEC61089 technical data
Code | Nominal Area | Stranding | Overall Diameter | Weight | Rated Strength | Electrical Resistance | Current Rating* | |
AWG&MCM | mm2 | No.×mm | mm | kg/km | KN | Ω/Km | A | |
Peachbell | 6 | 13.3 | 7/1.56 | 4.68 | 36.6 | 2.53 | 2.1477 | 75 |
Rose | 4 | 21.1 | 7/1.96 | 5.88 | 58.2 | 3.91 | 1.3606 | 99 |
Iris | 2 | 33.6 | 7/2.47 | 7.41 | 92.6 | 5.99 | 0.8567 | 132 |
Pansy | 1 | 42.4 | 7/2.78 | 8.34 | 116.6 | 7.3 | 0.6763 | 153 |
Poppy | 1/0.0 | 53.5 | 7/3.12 | 9.36 | 147.2 | 8.84 | 0.5369 | 176 |
Aster | 2/0.0 | 67.4 | 7/3.50 | 10.5 | 185.7 | 11.1 | 0.4267 | 203 |
Phlox | 3/0.0 | 85 | 7/3.93 | 11.79 | 233.9 | 13.5 | 0.3384 | 234 |
Oxlip | 4/0.0 | 107.2 | 7/4.42 | 13.26 | 295.2 | 17 | 0.2675 | 270 |
Valerian | 250 | 126.7 | 19/2.91 | 14.55 | 348.6 | 20.7 | 0.2274 | 299 |
Sneezewort | 250 | 126.7 | 7/4.80 | 14.4 | 348.8 | 20.1 | 0.2269 | 299 |
Laurel | 266.8 | 135.2 | 19/3.01 | 15.05 | 372.2 | 22.1 | 0.2125 | 312 |
Daisy | 266.8 | 135.2 | 7/4.96 | 14.88 | 372.3 | 21.4 | 0.2125 | 311 |
Peony | 300 | 152 | 19/3.19 | 15.95 | 418.3 | 24.3 | 0.1892 | 335 |
Tulip | 336.4 | 170.5 | 19/3.38 | 16.9 | 469.5 | 27.3 | 0.1686 | 359 |
Daffodil | 350 | 177.3 | 19/3.45 | 17.25 | 487.9 | 28.4 | 0.1618 | 369 |
Canna | 397.5 | 201.4 | 19/3.67 | 18.35 | 554.9 | 31.6 | 0.143 | 397 |
Goldentuft | 450 | 228 | 19/3.91 | 19.55 | 627.6 | 35 | 0.126 | 429 |
Syringa | 477 | 241.7 | 37/2.88 | 20.16 | 664.8 | 38.6 | 0.1192 | 444 |
Cosmos | 477 | 241.7 | 19/4.02 | 20.1 | 664.8 | 37 | 0.1192 | 444 |
Hyacinth | 500 | 253.3 | 37/2.95 | 20.65 | 696.8 | 40.5 | 0.1136 | 458 |
Zinnia | 500 | 253.3 | 19/4.12 | 20.6 | 697.1 | 38.9 | 0.1134 | 458 |
Dahlia | 556.5 | 282 | 19/4.35 | 21.75 | 775.8 | 43.3 | 0.1018 | 489 |
Mistletoe | 556.5 | 282 | 37/3.12 | 21.84 | 775.7 | 44.3 | 0.1016 | 490 |
Meadowsweet | 600 | 304 | 37/3.23 | 22.61 | 836.3 | 47.5 | 0.0948 | 511 |
Orchid | 636 | 322.3 | 37/3.33 | 23.31 | 886.9 | 50.4 | 0.0892 | 530 |
Heuchera | 650 | 329.4 | 37/3.37 | 23.59 | 907.4 | 51.7 | 0.0871 | 538 |
Code | Nominal Area | Stranding | Overall Diameter | Weight | Rated Strength | Electrical Resistance | Current Rating* | |
AWG&MCM | mm2 | No.×mm | mm | kg/km | KN | Ω/Km | A | |
Flag | 700 | 354.7 | 61/2.72 | 24.48 | 975.8 | 57.1 | 0.0811 | 561 |
Varbena | 700 | 354.7 | 37/3.49 | 24.43 | 975.7 | 55.4 | 0.0812 | 561 |
Nasturtium | 715.5 | 362.6 | 61/2.75 | 24.75 | 998.5 | 58.4 | 0.0793 | 569 |
Violet | 715.5 | 362.6 | 37/3.53 | 24.71 | 998.5 | 56.7 | 0.0794 | 568 |
Cattail | 750 | 380 | 61/2.82 | 25.38 | 1046 | 60.3 | 0.0754 | 587 |
Petunia | 750 | 380 | 37/3.62 | 25.34 | 1046 | 58.6 | 0.0755 | 586 |
Lilac | 795 | 402.8 | 61/2.90 | 26.1 | 1110 | 63.8 | 0.0713 | 607 |
Arbutus | 795 | 402.8 | 37/3.72 | 26.04 | 1109 | 61.8 | 0.0715 | 605 |
Snapdragon | 900 | 456 | 61/3.09 | 27.81 | 1256 | 70.8 | 0.0628 | 654 |
Cockscomb | 900 | 456 | 37/3.96 | 27.72 | 1256 | 68.4 | 0.0631 | 652 |
Goldenrod | 954 | 483.4 | 61/3.18 | 28.62 | 1331 | 75 | 0.0593 | 677 |
Magnolia | 954 | 483.4 | 37/4.08 | 28.56 | 1331 | 72.6 | 0.0594 | 676 |
Camellia | 1000 | 506.7 | 61/3.25 | 29.25 | 1394 | 78.3 | 0.0568 | 695 |
Hawkweed | 1000 | 506.7 | 37/4.18 | 29.26 | 1395 | 76.2 | 0.0566 | 696 |
Larkspur | 1033.5 | 523.7 | 61/3.31 | 29.79 | 1442 | 81.3 | 0.0547 | 710 |
Bluebell | 1033.5 | 523.7 | 37/4.25 | 29.75 | 1441 | 78.8 | 0.0547 | 710 |
Marigold | 1113 | 564 | 61/3.43 | 30.87 | 1553 | 87.3 | 0.051 | 740 |
Hawthorn | 1192.5 | 604.2 | 61/3.55 | 31.95 | 1662 | 93.5 | 0.0476 | 771 |
Narsissus | 1272 | 644.5 | 61/3.67 | 33.03 | 1774 | 98.1 | 0.0445 | 802 |
Columbine | 1351 | 694.8 | 61/3.78 | 34.02 | 1884 | 104 | 0.042 | 829 |
Carnation | 1431 | 725.1 | 61/3.89 | 35.01 | 1997 | 108 | 0.0396 | 858 |
Gladiolus | 1510.5 | 765.4 | 61/4.00 | 36 | 2108 | 114 | 0.0375 | 885 |
Coreopsis | 1590 | 805.7 | 61/4.10 | 36.9 | 2216 | 120 | 0.0357 | 911 |
Jassamine | 1750 | 886.7 | 61/4.30 | 38.7 | 2442 | 132 | 0.0324 | 962 |
Cowslip* | 2000 | 1013 | 91/3.77 | 41.47 | 2787 | 153 | 0.0286 | 1032 |
Sagebrush* | 2250 | 1140 | 91/3.99 | 43.89 | 3166 | 167 | 0.0255 | 1099 |
Lupine* | 2500 | 1267 | 91/4.21 | 46.31 | 3519 | 186 | 0.0229 | 1163 |
Bitterrot* | 2750 | 1393 | 91/4.42 | 48.62 | 3872 | 205 | 0.0208 | 1223 |
Trillium* | 3000 | 1520 | 127/3.90 | 50.7 | 4226 | 223 | 0.0193 | 1271 |
Bluebonnet* | 3500 | 1773 | 127/4.22 | 54.86 | 4977 | 261 | 0.0165 | 1373 |
AAC conductor 477MCM 37/2.88mm All aluminum alloy conductor ASTM B231/231M IEC61089 packing info
About Zhenglan Cable
Zhenglan Cable Technology Co., Ltd has factory workshop taking up about 60000SQM is located in Wuzhi County, Jiaozuo city, Henan province, in the middle of China. Oversea sales center locates in Zhengzhou city, Henan, about 10minutes walk to Zhengdong Railway station, 45minutes' drive to Xinzheng International Airport.
Our main products are
overhead transmission line use bare conductor(ACSR, AAC, AAAC etc)
1-35kv overhead transmission line use insulated conductor
power distribution use 0.6/1kv, 1.8/3kv PVC/XLPE/PE insulated LV(low voltage) power cable armored or unarmored
power distribution use 3.6/6kv, 6/10kv,8.7/10kv, 8.7/15kv, 12/20kv, 21/35kv, 26/35kv XLPE insulated MV(medium voltage) power cable armored or unarmored;
300/300V, 300/500V, 450/750V cotrol cable, house wire
The reason you choose us:
- We are profeesional cable supplier for more than 10 years.
- Not only provide you good-quality products,but also service you well.
- We have high work efficency.
If you are interested, please do not hesitate to contact us.Any inquiry will be welcomed.
We are China 477MCM 37/2.88mm AAC All Aluminum Alloy Conductor ASTM B231/231M IEC61089 manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Tags: 37/2.88mm AAC All Aluminum Alloy Conductor, 477MCM AAC All Aluminum Alloy Conductor, 477MCM aac cable, Bare Aluminum ConductorFAST AND RELIABLE SERVICE FOR YOUR PROJECT
Contact our trained experts today to find your perfect power solution.
ASK A QUESTION© 2020 Galaxy Electric Country Code Sitemap Cable Cable Drum